Premium Information is available for this item - Upgrade for $1 a day

5962-01-371-3188

Memory Microcircuit

5962013713188 013713188 725925-50 ROM/PROM 52520-1

A circuit designed to store information and/or coded instructions. Item has pins or other connections to install in a computer or computing device. Does not include magnetic drums, tapes, punched cards or the like. For items that have portable type connections see MEMORY, PORTABLE, SOLID STATE. View more Memory Microcircuit

5962-01-371-3188 MICROCIRCUIT,MEMORY 5962013713188 013713188

Managed by United States
NSN Created on 10 Feb 1993
Data Last Changed
May 2023
NATO Update Count
6
NATO Data Quality
5962-01-371-3188 MICROCIRCUIT,MEMORY 5962013713188 013713188 1/1
NSN 5962-01-371-3188 (Generic Image) 1/1

5962-01-371-3188 Stock and Availability Marketplace 5962-01-371-3188

5962-01-371-3188 Related Documents Related Documents 5962-01-371-3188 5+ Documents (More...)

725925-50 ROM/PROM 52520-1 A circuit designed to store information and/or coded instructions.
Quotation Updated Every Day 5962-01-371-3188 RQST NE Updated Every Day 5962-01-371-3188 RQST Updated
Every Day 5962-01-371-3188 RQST NE Related Documents 5962-01-371-3188 5+ Documents ( More... ) https
$1 a day Upgrade your Account Upgrade 5962-01-371-3176Memory Microcircuit5962013713176 013713176 ROM/PROM
FAMILY 193 725925-50 52552-2 A circuit designed to store information and/or coded instructions.
FAMILY 193 725925-50 52550-4 A circuit designed to store information and/or coded instructions.
$1 a day Upgrade your Account Upgrade 5962-01-371-2694Memory Microcircuit5962013712694 013712694 ROM/PROM
725925-50 52547-2 A circuit designed to store information and/or coded instructions.
ROM/PROM. MICROCIRCUIT,MEMORY 120 EA NS Request Quotation Subscribe to View Vendor Details...
$1 a day Upgrade your Account Upgrade 5962-01-371-3175Memory Microcircuit5962013713175 013713175 ROM/PROM
FAMILY 193 725925-50 52550-4 A circuit designed to store information and/or coded instructions.
www.nsnlookup.com /fsg-59/fsc-5962/us 5962-01-371-3175 Memory Microcircuit 5962013713175013713175 ROM/PROM
013712694 Upgrade your Account Upgrade 5962-01-371-2694Memory Microcircuit5962013712694 013712694 ROM/PROM
63068140010116306 010116306,725925 8140010116306 https//www.nsnlookup.com /fsg-59/fsc-5962/us 5962-01-371-3188
Memory Microcircuit 5962013713188 013713188 $1 a day Upgrade your Account Upgrade 5962-01-371-3188Memory

5962-01-371-3188 Demil Restrictions 5962-01-371-3188

DEMIL: Q | DEMILI: | CRITICALITY: X | HMIC: N | PMIC: A | EDC: B | ADPEC: 0

5962-01-371-3188 is a Memory Microcircuit that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is a confirmed Commerce Control List Item (CCLI). This item is not suspected to be hazardous. This item does not contain a precious metal. This item is sensitive to Electrostatic Discharge.

5962-01-371-3188 HTS and ScheduleB Import and Export 5962-01-371-3188

5962-01-371-3188 End Users End Users 5962-01-371-3188

US Navy (N9BN)
Effective Date:
1 Aug 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD
Spain (YB01)
Effective Date:
1 Jul 2003

5962-01-371-3188 Manufacturers Approved Sources 5962-01-371-3188

5962-01-371-3188 Technical Data Datasheet 5962-01-371-3188

Characteristic
Specifications
FIIG
A458A0
Body Height [ADAU]
0.140 Inches Minimum And 0.187 Inches Maximum
Body Length [ADAQ]
1.435 Inches Minimum And 1.485 Inches Maximum
Body Width [ADAT]
0.515 Inches Minimum And 0.600 Inches Maximum
Capitance Rating Per Characteristic [CZEP]
6.00 Input Picofarads Maximum And 12.00 Output Picofarads Maximum
Current Rating Per Characteristic [CTQX]
100.00 Milliamperes Maximum Supply
Features Provided [CBBL]
Hermetically Sealed And Ultraviolet Erasable And Electrostatic Sensitive And Programmed And W/Enable And W/Disable And W/Inhibit And Monolithic
Memory Device Type [CZER]
Eprom
Operating Temp Range [AFGA]
+0.0 To 70.0 Deg Celsius
Output Logic Form [CQWX]
N-Type Metal Oxide-Semiconductor Logic
Inclosure Configuration [CQSZ]
Dual-In-Line
Inclosure Material [CQSJ]
Ceramic Or Glass Or Metal
Input Circuit Pattern [CQZP]
17 Input
Time Rating Per Chacteristic [CZEQ]
250.00 Nanoseconds Maximum Access
Voltage Rating And Type Per Characteristic [CZEN]
-0.6 Volts Minimum Power Source And 7.0 Volts Maximum Power Source
Storage Temp Range [AFJQ]
-65.0 To 125.0 Deg Celsius
Terminal Surface Treatment [CWSG]
Solder
Terminal Type And Quantity [TTQY]
28 Printed Circuit

5962-01-371-3188 Stock, Inventory and Procurement DLA Procurement Analysis 5962-01-371-3188

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5962-01-371-3188 Management Data Management Data 5962-01-371-3188

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Defense Logistics Agency (DS)
EA
Subscribe
1
Mar 2020
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5962-01-371-3188 Similar Items Similar Supply Items to 5962-01-371-3188

5962-01-371-3188 Freight Data Freight Information 5962-01-371-3188

5962-01-371-3188 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 5962-01-371-3188 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 5962-01-371-3188 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 5962-01-371-3188 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 738 for ocean manifesting and military sealift. 5962-01-371-3188 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 5962-01-371-3188 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5962-01-371-3188 Packaging Data Packaging Data 5962-01-371-3188

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
--
--
--
--
Special requirements

Intermediate Pack Level

Quantity of Unit Packs
Container
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box

5962-01-371-3188 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5962-01-371-3188 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
J

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: