Premium Information is available for this item - Upgrade for $1 a day
5962-01-333-6219
Memory Microcircuit
5962013336219 013336219 ROM/PROM CR711983 711983/SD01 CDP1834C
A circuit designed to store information and/or coded instructions. Item has pins or other connections to install in a computer or computing device. Does not include magnetic drums, tapes, punched cards or the like. For items that have portable type connections see MEMORY, PORTABLE, SOLID STATE. View more Memory Microcircuit
![]()
June 2023
10

Marketplace 5962-01-333-6219
Request a Quotation from participating marketplace vendors
Related Documents 5962-01-333-6219 5+ Documents (More...)
ROM/PROM. MICROCIRCUIT,MEMORY 120 EA NS Request Quotation Subscribe to View Vendor Details...
Quotation FedMall Updated Every 15 Minutes 5962-01-333-6219 BUY NE FedMall Updated Every Day 5962-01
ROM/PROM.
Memory Microcircuit 5962013336219 013336219 $1 a day Upgrade your Account Upgrade 5962-01-333-6219Memory
Memory Microcircuit 5962013336219 013336219 your Account Upgrade 5962-01-333-6219Memory Microcircuit5962013336219
013336219 ROM/PROM CR711983 711983 333-6219 BUY NE FedMall Updated Every Day 5962-01 https//www.nsnlookup.com
Memory Microcircuit 5962013336219 013336219 your Account Upgrade 5962-01-333-6219Memory Microcircuit5962013336219
013336219 ROM/PROM CR711983 711983 www.nsnlookup.com /fsg-53/fsc-5305/fr 5305-14-283-2358 Vis 5305142832358
Memory Microcircuit 5962013336219 013336219 your Account Upgrade 5962-01-333-6219Memory Microcircuit5962013336219
013336219 ROM/PROM CR711983 711983 https//www.nsnlookup.com /fsg-53/fsc-5305/fr 5305-14-283-2358 Vis
Restrictions 5962-01-333-6219
5962-01-333-6219 is a Memory Microcircuit that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is a confirmed Commerce Control List Item (CCLI). This item is not suspected to be hazardous. This item does not contain a precious metal. This item is sensitive to Electrostatic Discharge.
Import and Export 5962-01-333-6219
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5962-01-333-6219
- US Army (A918)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- A196
- Supplementary Receivers:
- CL
- US Marine Corps (MC49)
- Effective Date:
- 1 Aug 2006
Approved Sources 5962-01-333-6219
- Part Number
- Manufacturer
- Status
- CR711983
- Manufacturer
- 23386 - Thales Defense & Security Inc (Active)
- Primary Buy
- Primary Buy
- ROM/PROM
- 16236 - Dla Land And Maritime (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- CR711983
- K0162 - Thales Uk Limited Secure (Active)
- Secondary Buy
- Secondary Buy
- 711983/SD01
- 23386 - Thales Defense & Security Inc (Active)
- Secondary Buy
- Secondary Buy
- CDP1834C
- 34371 - Renesas Electronics America Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- CR711983
- K8997 - Racal Radio Ltd (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5962-01-333-6219
- Characteristic
- Specifications
- FIIG
- Specifications
- A458A0
- End Item Identification [AGAV]
- 5865-01-188-3309 Jammer System,Respo
- Body Height [ADAU]
- 2.16 Millimeters Minimum And 3.68 Millimeters Maximum
- Body Length [ADAQ]
- 29.98 Millimeters Minimum And 30.98 Millimeters Maximum
- Features Provided [CBBL]
- Positive Outputs And Static Operation And Programmed
- Maximum Power Dissipation Rating [AEHX]
- 500.0 Milliwatts
- Memory Device Type [CZER]
- Rom
- Memory Capacity [CZZZ]
- Unknown
- Operating Temp Range [AFGA]
- -55.0/+125.0 Deg Celsius
- Output Logic Form [CQWX]
- Complementary-Metal Oxide-Semiconductor Logic
- Inclosure Configuration [CQSZ]
- Dual-In-Line
- Inclosure Material [CQSJ]
- Ceramic
- Input Circuit Pattern [CQZP]
- 12 Input
- Time Rating Per Chacteristic [CZEQ]
- 850.00 Nanoseconds Maximum Propagation Delay Time, Low To High Level Output And 850.00 Nanoseconds Maximum Propagation Delay Time, High To Low Level Output
- Voltage Rating And Type Per Characteristic [CZEN]
- 7.0 Volts Maximum Power Source
- Storage Temp Range [AFJQ]
- -65.0/+150.0 Deg Celsius
- Terminal Surface Treatment [CWSG]
- Solder
- Terminal Type And Quantity [TTQY]
- 24 Printed Circuit
DLA Procurement Analysis 5962-01-333-6219
Management Data 5962-01-333-6219
Army
- Materiel Category and Inventory Manager:
- Q
- Electronics Materiel (DLA/GSA Items)
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 00
- DLA/GSA Material
DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Marine Corps
- Stores Account:
- 1
- Stock Fund Account Item
- Combat Essentiality:
- 0
- Non-combat Essential End Item
- Echelon Management:
- B2
- Operational Test:
- No Special Procedures
- Physical Category:
- 1
- Bin
Similar Supply Items to 5962-01-333-6219


















Freight Information 5962-01-333-6219
5962-01-333-6219 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 5962-01-333-6219 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 5962-01-333-6219 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 5962-01-333-6219 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 738 for ocean manifesting and military sealift. 5962-01-333-6219 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 5962-01-333-6219 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5962-01-333-6219
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- --
- --
- --
- --
- Special requirements
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
Contracting Technical Data File (CTDF) 5962-01-333-6219 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: