Premium Information is available for this item - Upgrade for $1 a day
5962-01-068-2623
Linear Microcircuit
5962010682623 010682623 1040490 1040490-1 755002A7710-1 CP9292 21-14-27030-00
A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal. View more Linear Microcircuit
November 2023
21

Marketplace 5962-01-068-2623
Request a Quotation from participating marketplace vendors
Related Documents 5962-01-068-2623 5+ Documents (More...)
Day 5962-01-068-2623 RQST Updated Every Day 5962-01-068-2623 RQST NE Related Documents 5962-01-068-2623
RQST Updated Every Day 5962-01-068-2623 RQST NE Related Documents 5962-01-068-2623 RQST Updated
Linear Microcircuit 5962010682623 010682623 -01-068-2623Linear Microcircuit5962010682623 010682623
1040490 1040490-1 755002A7710-1 CP9292 21-14-27030 5962-01-068-2623 Linear Microcircuit 5962010682623010682623
Linear Microcircuit 5962010682623 010682623 988537730 Cancelled - Replaced by NSN 5962-01-068-2623
5820010279071 010279071,1623725-100 59/fsc-5930/us 5930-01-074-8849 Code Indicating https by NSN 5962-01-068-2623
Linear Microcircuit 5962010682623 010682623 58/fsc-5820/us 5820-01-027-9071 Radio Set 5820010279071
Restrictions 5962-01-068-2623
5962-01-068-2623 is a Linear Microcircuit that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a confirmed Commerce Control List Item (CCLI). This item is not suspected to be hazardous. The precious metals content of this item is unknown. This item is sensitive to Electrostatic Discharge.
Import and Export 5962-01-068-2623
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5962-01-068-2623
- US Marine Corps (MC49)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- MC13
- US Navy (N9BN)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5962-01-068-2623
- Part Number
- Manufacturer
- Status
- 755002A7710-1
- Manufacturer
- 87990 - Quartermaster General (Obsolete)
- Original Design
- Original Design
- 1040490
- 55267 - Raytheon Company (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 1040490-1
- 55267 - Raytheon Company (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 755002A7710-1
- 05869 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- CP9292
- 0F962 - Micro-Precision Technologies, Inc. (Active)
- Secondary Buy
- Secondary Buy
- 21-14-27030-00
- S0522 - Tadiran Ltd (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 1040490
- 00816 - Palomar Products, Inc. (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5962-01-068-2623
- Characteristic
- Specifications
- FIIG
- Specifications
- A458A0
- End Item Identification [AGAV]
- 5820-01-027-9071
- Body Height [ADAU]
- 0.230 Inches Maximum
- Body Length [ADAQ]
- 1.300 Inches Maximum
- Body Width [ADAT]
- 1.300 Inches Maximum
- Design Function And Quantity [CSSL]
- 1 Filter, Active
- Features Provided [CBBL]
- Hermetically Sealed And Hybrid And Negative Outputs And Positive Outputs
- Maximum Power Dissipation Rating [AEHX]
- 125.0 Milliwatts
- Operating Temp Range [AFGA]
- -46.0/+86.0 Deg Celsius
- Inclosure Configuration [CQSZ]
- Dual-In-Line
- Inclosure Material [CQSJ]
- Ceramic And Glass
- Input Circuit Pattern [CQZP]
- 14 Input
- Time Rating Per Chacteristic [CZEQ]
- 125.00 Nanoseconds Maximum Propagation Delay Time, Low To High Level Output
- Voltage Rating And Type Per Characteristic [CZEN]
- 12.0 Volts Nominal Power Source
- Storage Temp Range [AFJQ]
- -65.0/+165.0 Deg Celsius
- Terminal Type And Quantity [TTQY]
- 25 Printed Circuit
- Terminal Surface Treatment [CWSG]
- Solder
- Test Data Document [TEST]
- 87990-755002A7710 Drawing (This Is The Basic Governing Drawing, Such As A Contractor Drawing, Original Equipment Manufacturer Drawing, Etc.; Excludes Any Specification, Standard Or Other Document That May Be Referenced In A Basic Governing Drawing)
Weapon Systems (WSDC) 5962-01-068-2623
DLA Procurement Analysis 5962-01-068-2623
- Last Stock Position:
- 10 In Stock
- DLA Administrative Lead Time:
- Subscribe
- DLA Production Lead Time:
- Subscribe
Management Data 5962-01-068-2623
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Marine Corps
- Stores Account:
- 1
- Stock Fund Account Item
- Combat Essentiality:
- 5
- Critical Repair Part to a Combat Essential End Item
- Echelon Management:
- B2
- Material Identification:
- T
- Maintenance Float Secondary Non-depot Reparables
- Operational Test:
- No Special Procedures
Similar Supply Items to 5962-01-068-2623


















Freight Information 5962-01-068-2623
5962-01-068-2623 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 5962-01-068-2623 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 5962-01-068-2623 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5962-01-068-2623 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 5962-01-068-2623 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5962-01-068-2623
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- --
- --
- --
- --
- Special requirements
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
Procurement History 5962-01-068-2623 1 Records
Contracting Technical Data File (CTDF) 5962-01-068-2623 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: