Premium Information is available for this item - Upgrade for $1 a day
5961-01-187-0789
Diode Semiconductor Device
5961011870789 011870789 805163-6 RA400 SDA150-6 SA8446 533167-6
A two electrode semiconductor device having an asymmetrical voltage - current characteristic. May or may not include mounting hardware and/or heatsink. Excludes LIGHT EMITTING DIODE and SEMICONDUCTOR DEVICE,PHOTO. For items containing material such as selenium and copper oxide, see RECIFIER, METALLIC. View more Diode Semiconductor Device
June 2023
18
Marketplace 5961-01-187-0789
Request a Quotation from participating marketplace vendors
Related Documents 5961-01-187-0789 5+ Documents (More...)
JavaScript in your web browser . 5895-01-302-7775Radio Frequency Amplifier5895013027775 013027775 MOD RA400
Approved Sources 5895-01-302-7775 Part NumberManufacturerStatusMOD RA400 0CGV1 - Marseco Inc (Obsolete
enable JavaScript in your web browser . 5895-14-429-2001Receiver Group5895144292001 144292001 RA400
Approved Sources 5895-01-302-7775 Part NumberManufacturerStatusMOD RA400 0CGV1 - Marseco Inc (Obsolete
Restrictions 5961-01-187-0789
5961-01-187-0789 is a Diode Semiconductor Device that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a confirmed Commerce Control List Item (CCLI). This item is not suspected to be hazardous. This item does not contain a precious metal. This item is sensitive to Electrostatic Discharge.
Import and Export 5961-01-187-0789
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5961-01-187-0789
- US Coast Guard (C911)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- C007
- US Air Force (FXGX)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Dec 2013
- Supplementary Collaborators:
- GG
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Germany (ZG01)
- Effective Date:
- 1 Jan 2015
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2005
Approved Sources 5961-01-187-0789
- Part Number
- Manufacturer
- Status
- 805163-6
- Manufacturer
- 96214 - Raytheon Company (Active)
- Primary Buy
- Primary Buy
- RA400
- 60211 - Voltage Multipliers Inc. (Active)
- Secondary Buy
- Secondary Buy
- SDA150-6
- 30043 - Solid State Devices, Inc (Active)
- Secondary Buy
- Secondary Buy
- SA8446
- 14099 - Semtech Corporation (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 533167-6
- 96214 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5961-01-187-0789
- Characteristic
- Specifications
- FIIG
- Specifications
- A110A0
- Semiconductor Material [CTMZ]
- Silicon
- Voltage Rating In Volts Per Characteristic [CTQN]
- 20000.0 Maximum Reverse Voltage, Peak
- Inclosure Material [ABBH]
- Plastic
- Mounting Method [AXGY]
- Terminal
- Terminal Length [ABJT]
- 2.000 Inches Minimum
- Terminal Type And Quantity [TTQY]
- 2 Uninsulated Wire Lead
- Overall Length [ABHP]
- 3.500 Inches Nominal
- Overall Height [ABKW]
- 0.250 Inches Nominal
- Overall Width [ABMK]
- 0.500 Inches Nominal
Weapon Systems (WSDC) 5961-01-187-0789
DLA Procurement Analysis 5961-01-187-0789
Management Data 5961-01-187-0789
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 5961-01-187-0789
Freight Information 5961-01-187-0789
5961-01-187-0789 has freight characteristics managed by Germany.It has a National Motor Freight Classification (NMFC) of 063025. A Sub NMFC of Z. It has a NMFC Description of SEMICONDUCTORS/DEVICES NOI ETC. 5961-01-187-0789 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34525 which rates the freight between FCL and LCL. 5961-01-187-0789 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5961-01-187-0789 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 5961-01-187-0789 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5961-01-187-0789
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- Special requirements
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5961-01-187-0789 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- T
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: