Premium Information is available for this item - Upgrade for $1 a day
5961-01-029-0989
Unitized Semiconductor Devices
5961010290989 010290989 2896452-1 DMS 80064B
Two or more discrete semiconductor devices such as diode(s) and/or transistor(s), permanently cased, encapsulated, or potted together to form an inseparable unit. Excludes devices having one or more components other than semiconductor devices. The individually distinct devices forming the unit may be internally connected. The unit in itself does not perform a complete specific function and cannot be assigned a more definite item name. It may include or consist of inseparable matched pairs. May or may not include mounting hardware and/or heatsink. For interconnected items arranged in stack(s), see RECTIFIER, SEMICONDUCTOR DEVICE. For items formed on or within a semiconductor material substrate, formed on an insulating substrate or formed on a combination of both of these types, see MICROCIRCUIT (as modified). Excludes NETWORK (as modified); ABSORBER, OVERVOLTAGE; SEMICONDUCTOR DEVICE SET; and SEMICONDUCTOR DEVICE ASSEMBLY. Do not use if more specific name applies. View more Unitized Semiconductor Devices
May 2023
19
Marketplace 5961-01-029-0989
Request a Quotation from participating marketplace vendors
Related Documents 5961-01-029-0989 5+ Documents (More...)
DAC 5 517-011 14936 - General Semiconductor Inc (Active) Canceled/Obsolete RNCC 5 RNVC DMS 80064B DAC
Account Upgrade 5961-01-029-0989Unitized Semiconductor Devices5961010290989 010290989 2896452-1 DMS
Account Upgrade 5961-01-029-0989Unitized Semiconductor Devices5961010290989 010290989 2896452-1 DMS
Account Upgrade 5961-01-029-0989Unitized Semiconductor Devices5961010290989 010290989 2896452-1 DMS
Account Upgrade 5961-01-029-0989Unitized Semiconductor Devices5961010290989 010290989 2896452-1 DMS
80064B 352-0774-010 DMS 80064B your Account Upgrade 5961-00-013-9643Transistor5961000139643 000139643
2896452-1 DMS 80064B 352-0774-010 DMS 80064B your Account Upgrade 5961-00-013-9643Transistor5961000139643
80064B Account Upgrade 5961-01-034-8299Transistor5961010348299 010348299 MU634 431-027-9101 2N4353X DMS 80064B
DAC 5 517-011 14936 - General Semiconductor Inc (Active) Canceled/Obsolete RNCC 5 RNVC DMS 80064B DAC
Account Upgrade 5961-01-029-0989Unitized Semiconductor Devices5961010290989 010290989 2896452-1 DMS
Restrictions 5961-01-029-0989
5961-01-029-0989 is a Unitized Semiconductor Devices that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5961-01-029-0989
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5961-01-029-0989
- US Navy (N9BN)
- Effective Date:
- 1 Nov 2005
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
- Spain (YB01)
- Effective Date:
- 1 May 1997
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Denmark (ZS01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5961-01-029-0989
- Part Number
- Manufacturer
- Status
- 2896452-1
- Manufacturer
- 10001 - Navair And Navsea Managed (Active)
- Primary Buy
- Primary Buy
- 2896452-1
- 3B150 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- 2896452-1
- 54X10 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- DMS 80064B
- 16236 - Dla Land And Maritime (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 2896452-1
- 49956 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 2896452-1
- 32293 - Intersil Inc Sub Of General Electric (Obsolete)
- Advisory Reference
- Advisory Reference
Datasheet 5961-01-029-0989
- Characteristic
- Specifications
- FIIG
- Specifications
- A110A0
- Component Name And Quantity [ASKA]
- 2 Transistor
- Current Rating Per Characteristic [CTQX]
- -50.00 Milliamperes Maximum Drain Current All Transistor
- Features Provided [CBBL]
- Hermetically Sealed Case
- Maximum Operating Temp Per Measurement Point [CTSG]
- 125.0 Deg Celsius Junction
- Mounting Method [AXGY]
- Terminal
- Inclosure Material [ABBH]
- Metal
- Power Rating Per Characteristic [CTRD]
- 112.0 Milliwatts Maximum Total Power Dissipation All Transistor
- Semiconductor Material [CTMZ]
- Silicon All Transistor
- Overall Diameter [ADAV]
- 0.335 Inches Minimum And 0.370 Inches Maximum
- Overall Length [ABHP]
- 0.240 Inches Minimum And 0.260 Inches Maximum
- Voltage Rating In Volts Per Characteristic [CTQN]
- -35.0 Maximum Drain To Source Voltage All Transistor And -35.0 Maximum Gate Non-Trigger Voltage, Dc All Transistor And -40.0 Maximum Gate To Source Voltage All Transistor
- Terminal Circle Diameter [AYQS]
- 0.200 Inches Nominal
- Terminal Length [ABJT]
- 0.500 Inches Minimum
- Terminal Type And Quantity [TTQY]
- 8 Uninsulated Wire Lead
DLA Procurement Analysis 5961-01-029-0989
Management Data 5961-01-029-0989
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 5961-01-029-0989
Freight Information 5961-01-029-0989
5961-01-029-0989 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063025. A Sub NMFC of Z. It has a NMFC Description of SEMICONDUCTORS/DEVICES NOI ETC. 5961-01-029-0989 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34525 which rates the freight between FCL and LCL. 5961-01-029-0989 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5961-01-029-0989 is not classified as a special type of cargo when transported by water. 5961-01-029-0989 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5961-01-029-0989
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- Special requirements
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5961-01-029-0989 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: