Premium Information is available for this item - Upgrade for $1 a day
5961-00-724-2784
Transistor
5961007242784 007242784 RELEASE3853 2N2035 472-0493-001
An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO. View more Transistor
![]()
November 2023
17

Marketplace 5961-00-724-2784
Request a Quotation from participating marketplace vendors
Related Documents 5961-00-724-2784 4+ Documents (More...)
to View Vendor Details... 2N2035 TRANSISTOR 5 EA NS Request Quotation Updated Every Day 5961-00-724-2784
5961-00-724-2784 4+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5961/us 5961-00-724-2784
1 EA NS Request Quotation 2N2035 TRANSISTOR 1 EA NS Request Quotation Subscribe to View Vendor Details
... 2N2035 TRANSISTOR 6 EA NS Request Quotation Subscribe to View Vendor Details... 2N2035 TRANSISTOR
Upgrade for $1 a day Upgrade your Account Upgrade 5961-00-954-9582Transistor5961009549582 009549582 RELEASE3853
Transistor 5961007242784 007242784 Upgrade for $1 a day Upgrade your Account Upgrade 5961-00-724
RELEASE3853 Transistor 5961009549582009549582 Upgrade for $1 a day Upgrade your Account Upgrade 5961-
Transistor 5961007242784 007242784 Upgrade for $1 a day Upgrade your Account Upgrade 5961-00-724
Restrictions 5961-00-724-2784
5961-00-724-2784 is a Transistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5961-00-724-2784
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5961-00-724-2784
- US Navy (N9BN)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- KE
- Brazil (YA01)
- Effective Date:
- 1 Nov 2008
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5961-00-724-2784
- Part Number
- Manufacturer
- Status
- 2N2035
- Manufacturer
- 80131 - Electronic Industries Association (Active)
- Primary Buy
- Primary Buy
- RELEASE3853
- 80131 - Electronic Industries Association (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 2N2035
- 34156 - Osi Optoelectronics, Inc (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 3B150 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 52333 - Api Electronics, Inc. (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 54X10 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 07256 - Silicon Transistor Corporation (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 30043 - Solid State Devices, Inc (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 31338 - Semitronics Corp (Active)
- Secondary Buy
- Secondary Buy
- 472-0493-001
- 94756 - The Boeing Company (Active)
- Secondary Buy
- Secondary Buy
- 2N2035
- 49956 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 2N2035
- 11058 - Csr Industries Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 2N2035
- 12930 - Sensitron Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 2N2035
- 30045 - Solid Power Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5961-00-724-2784
- Characteristic
- Specifications
- FIIG
- Specifications
- A110A0
- Electrode Internally-Electrically Connected To Case [ALBA]
- Collector
- Current Rating Per Characteristic [CTQX]
- 3.00 Amperes Source Cutoff Current Maximum And 1.00 Amperes Source Cutoff Current Minimum
- Features Provided [CBBL]
- Hermetically Sealed Case
- Maximum Operating Temp Per Measurement Point [CTSG]
- 200.0 Deg Celsius Case
- Mounting Method [AXGY]
- Terminal
- Semiconductor Material [CTMZ]
- Silicon
- Inclosure Material [ABBH]
- Metal
- Internal Configuration [ALAS]
- Junction Contact
- Power Rating Per Characteristic [CTRD]
- 14.0 Watts Small-Signal Input Power, Common-Collector Minimum
- Overall Diameter [ADAV]
- 0.500 Inches Minimum And 0.650 Inches Maximum
- Overall Length [ABHP]
- 0.270 Inches Minimum And 0.330 Inches Maximum
- Special Features [FEAT]
- Junction Pattern Arrangement: Npn
- Voltage Rating In Volts Per Characteristic [CTQN]
- 80.0 Maximum Breakdown Voltage, Collector-To-Base, Emitter Open And 10.0 Maximum Breakdown Voltage, Emitter-To-Base, Collector Open And 60.0 Maximum Breakdown Voltage, Collector-To-Emitter, Base Open
- Specification/Standard Data [ZZZK]
- 80131-Release3853 Professional/Industrial Association Specification
- Terminal Circle Diameter [AYQS]
- 0.272 Inches Minimum And 0.292 Inches Maximum
- Terminal Length [ABJT]
- 0.360 Inches Minimum And 0.440 Inches Maximum
- Terminal Type And Quantity [TTQY]
- 3 Uninsulated Wire Lead
Weapon Systems (WSDC) 5961-00-724-2784
DLA Procurement Analysis 5961-00-724-2784
Management Data 5961-00-724-2784
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5961-00-724-2784


















Freight Information 5961-00-724-2784
5961-00-724-2784 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063025. A Sub NMFC of Z. It has a NMFC Description of SEMICONDUCTORS/DEVICES NOI ETC. 5961-00-724-2784 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34525 which rates the freight between FCL and LCL. 5961-00-724-2784 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5961-00-724-2784 is not classified as a special type of cargo when transported by water. 5961-00-724-2784 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5961-00-724-2784
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- Special requirements
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5961-00-724-2784 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- Z
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: