Premium Information is available for this item - Upgrade for $1 a day

5950-01-085-1258

Power Transformer

5950010851258 010851258 325345-1

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer

5950-01-085-1258 TRANSFORMER,POWER 5950010851258 010851258

Managed by United States
NSN Created on 31 Oct 1979
Data Last Changed
May 2023
NATO Update Count
11
NATO Data Quality
5950-01-085-1258 TRANSFORMER,POWER 5950010851258 010851258 1/1
NSN 5950-01-085-1258 (Generic Image) 1/1

5950-01-085-1258 Stock and Availability Marketplace 5950-01-085-1258

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5950-01-085-1258 RQST NE eBay
eBay Updated Every Day
5950-01-085-1258 RQST eBay
Amazon Updated Every Day
5950-01-085-1258 RQST NE Amazon

5950-01-085-1258 Related Documents Related Documents 5950-01-085-1258 3+ Documents (More...)

Day 5950-01-085-1258 RQST Updated Every Day 5950-01-085-1258 RQST NE Related Documents 5950-01-085-1258
5950010851258010851258 Day 5950-01-085-1258 RQST Updated Every Day 5950-01-085-1258 RQST NE Related
Documents 5950-01-085-1258 more secondary winding Day 5950-01-085-1258 RQST Updated Every Day 5950-01
Documents 1420-14-404-5176 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-01-085-1258
Power Transformer 5950010851258 010851258 for $1 a day Upgrade your Account Upgrade 5950-01-085
-1258Power Transformer5950010851258 010851258 325345 Request a Quotation from participating marketplace
325345 for $1 a day Upgrade your Account Upgrade 5950-01-085-1258Power Transformer5950010851258 010851258
325345 //www.nsnlookup.com /fsg-59/fsc-5950/us 5950-01-085-1258 Power Transformer 5950010851258010851258
325345 https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-01-085-1258 Power Transformer 5950010851258

5950-01-085-1258 Demil Restrictions 5950-01-085-1258

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-01-085-1258 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-01-085-1258 End Users End Users 5950-01-085-1258

Germany (ZG01)
Effective Date:
1 Apr 1991
United Kingdom (ZK01)
Effective Date:
1 Apr 1991
Italy (ZR01)
Effective Date:
1 Apr 1991

5950-01-085-1258 Manufacturers Approved Sources 5950-01-085-1258

5950-01-085-1258 Technical Data Datasheet 5950-01-085-1258

Characteristic
Specifications
FIIG
A058B0
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
2.625 Inches Nominal Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
1.700 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
400.0 Hertz Nominal Single Component
Maximum Operating Temp [AEHZ]
155.0 Deg Celsius
Mounting Facility Quantity [AKPV]
4 Single Group
Mounting Method [AXGY]
Threaded Hole Single Group
Nominal Thread Size [CQJX]
0.112 Inches Single Group
Inclosure Type [AKNA]
Fully Inclosed
Input-Output Phase Relationship [ACZC]
Three Phase To Three Phase Single Component And Three Phase To Single Phase Single Component
Reliability Indicator [AARG]
Not Established
Overall Height [ABKW]
2.200 Inches Maximum
Overall Length [ABHP]
3.130 Inches Maximum
Overall Width [ABMK]
2.200 Inches Maximum
Transformer Winding Connection Type [ACZD]
Wye-Delta
Winding Operating Current [CRBZ]
0.6 Amperes Ac Minimum Single Component 3Rd Secondary
Winding Operating Current [CRBZ]
1.0 Amperes Ac Minimum Single Component 1St Secondary
Winding Operating Current [CRBZ]
1.0 Amperes Ac Minimum Single Component 2Nd Secondary
Winding Operating Current [CRBZ]
60.0 Milliamperes Ac Minimum Single Component 4Th Secondary
Winding Operating Voltage [CWJS]
106.00 Ac Volts Nominal Single Component Single Primary And 120.00 Ac Volts Nominal Single Component Single Primary
Winding Operating Voltage [CWJS]
115.00 Ac Volts Nominal Single Component 4Th Secondary
Winding Operating Voltage [CWJS]
19.00 Ac Volts Nominal Single Component 2Nd Secondary
Winding Operating Voltage [CWJS]
19.00 Ac Volts Nominal Single Component 1St Secondary
Winding Operating Voltage [CWJS]
6.45 Ac Volts Nominal Single Component 3Rd Secondary
Winding Shielding Method [ACZX]
Internal Shield Grounded To Inclosure Single Component
Terminal Type And Quantity [TTQY]
14 Feed Thru
Thread Series Designator [THSD]
Unc Single Group
Thread Quantity Per Inch [CMLP]
40 Single Group

5950-01-085-1258 Similar Items Similar Supply Items to 5950-01-085-1258

5950-01-085-1258 Freight Data Freight Information 5950-01-085-1258

5950-01-085-1258 has freight characteristics managed by Germany.. 5950-01-085-1258 has a variance between NMFC and UFC when transported by rail and the description should be consulted.