Premium Information is available for this item - Upgrade for $1 a day
5950-01-065-4549
Power Transformer
5950010654549 010654549 1054678-000 C2750 PEI 7834 3149794 SP-25K2-PS 5950PL1254740
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer
June 2023
26

Marketplace 5950-01-065-4549
Request a Quotation from participating marketplace vendors
Related Documents 5950-01-065-4549 5+ Documents (More...)
C2750 TRANSFORMER,POWER 123 EA NS Request Quotation Subscribe to View Vendor Details...
C2750 TRANSFORMER,POWER 1 EA NS Request Quotation Updated Every Day 5950-01-065-4549 RQST NE Updated
-837-D4 5200D4 31508D4 C2750 A fitting that forms an angle of less than 180 degrees (3.141 radians) from
-783T12 AA2750-783T12 C2750 A fitting having three connections with the branch connection fixed at 90
5120-21-868-0690 Cross Tip Screwdriver 5120218680690 218680690 218680690C2750 -783T12 AA2750-783T12 C2750
Account Upgrade 7643-01-568-8088Topographic Geospatial Products7643015688088 015688088M649XC2750M649 C2750
-833T3 C2750-833T 3 5196T3 A fitting that forms an angle of less than 180 degrees (3.141 radians) from
vendors Request Subscribe to View Vendor Details... 31506T3 ELBOW,TUBE 37 EA NS Request Quotation C2750
-783T12 AA2750-783T12 C2750 A fitting having three connections with the branch connection fixed at 90
C2750-783T12 TEE,TUBE TO BOSS RQST NS Request Quotation Subscribe to View Vendor Details...
Restrictions 5950-01-065-4549
5950-01-065-4549 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a US Munitions List Item and must be mutilated to scrap. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
End Users 5950-01-065-4549
- US Coast Guard (C911)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- C007
- US Navy (N9BN)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- GTHD
- Poland (WP01)
- Effective Date:
- 1 Nov 2003
- Spain (YB01)
- Effective Date:
- 1 May 1997
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2005
Approved Sources 5950-01-065-4549
- Part Number
- Manufacturer
- Status
- 3149794
- Manufacturer
- 10001 - Navair And Navsea Managed Original (Active)
- Original Design
- Original Design
- C2750
- 01378 - Spellman High-Voltage Electronics (Active)
- Secondary Buy
- Secondary Buy
- PEI 7834
- 13483 - Precision Electronics, Inc (Active)
- Secondary Buy
- Secondary Buy
- 3149794
- 56232 - Lockheed Martin Corporation (Active)
- Secondary Buy
- Secondary Buy
- SP-25K2-PS
- 20950 - Espey Mfg And Electronics Corp (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 5950PL1254740
- 9009H - Jednolity Indeks Materialowy - (Active)
- NATO Reference
- NATO Reference
- 1054678-000
- 56232 - Lockheed Martin Corporation (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5950-01-065-4549
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Body Height [ADAU]
- 2.380 Inches Maximum
- Body Length [ADAQ]
- 6.550 Inches Maximum
- Body Width [ADAT]
- 2.380 Inches Maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 5.926 Inches Minimum Single Mounting Facility Single Center Group And 5.966 Inches Maximum Single Mounting Facility Single Center Group
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 2.224 Inches Minimum Single Mounting Facility Single Center Group And 2.264 Inches Maximum Single Mounting Facility Single Center Group
- Features Provided [CBBL]
- W/Overload Protection
- Frequency Rating [ACZB]
- 25.0 Kilohertz Nominal Single Component
- Hazardous Locations/Environmental Protection [ABFE]
- Vibration Resistant
- Maximum Operating Temp [AEHZ]
- 71.0 Deg Celsius
- Maximum Transformer Power Rating [ACZF]
- 1.5 Kilovolt-Ampere Single Component
- Mounting Facility Quantity [AKPV]
- 4 Single Group
- Mounting Method [AXGY]
- Threaded Hole Single Group
- Nominal Thread Size [CQJX]
- 0.164 Inches Single Group
- Inclosure Type [AKNA]
- Fully Inclosed
- Input-Output Phase Relationship [ACZC]
- Single Phase To Single Phase Single Component
- Reliability Indicator [AARG]
- Not Established
- Special Features [FEAT]
- 1 Connector Is For High Voltage Hook Up
- Winding Operating Current [CRBZ]
- 100.0 Microamperes Ac Maximum Single Component Single Secondary
- Winding Function And Quantity [BPLC]
- 1 Primary Single Component And 1 Secondary Single Component
- Winding Operating Voltage [CWJS]
- 1.00 Dc Kilovolts Minimum Single Component Single Secondary And 2.00 Dc Kilovolts Maximum Single Component Single Secondary
- Winding Operating Voltage [CWJS]
- 13.79 Ac Volts Nominal Single Component Single Primary
- Winding Shielding Method [ACZX]
- Internal Shield Grounded To Inclosure Single Component
- Terminal Type And Quantity [TTQY]
- 2 Connector, Receptacle
- Thread Series Designator [THSD]
- Unc Single Group
Weapon Systems (WSDC) 5950-01-065-4549
DLA Procurement Analysis 5950-01-065-4549
Management Data 5950-01-065-4549
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Mar 2023
- US Coast Guard (GP)
- EA
- Subscribe
- 1
- EA
- Oct 2021
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Oct 2020
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- N
- X
- Formerly 6120
- X
- Defense Logistics Agency (DS)
- I
- X
- Formerly 6120
- X
- US Coast Guard (GP)
- C
- X
- Formerly 6120
- X
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 5950-01-065-4549
Freight Information 5950-01-065-4549
5950-01-065-4549 has freight characteristics managed by the Food and Drug Administration (FDA).It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-01-065-4549 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-01-065-4549 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-01-065-4549 is not classified as a special type of cargo when transported by water. 5950-01-065-4549 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5950-01-065-4549
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5950-01-065-4549 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- T
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: