Premium Information is available for this item - Upgrade for $1 a day

5950-01-042-1947

Power Transformer

5950010421947 010421947 800509-2 30P10CT

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer

5950-01-042-1947 TRANSFORMER,POWER 5950010421947 010421947

Managed by United States
NSN Created on 7 Jun 1977
Data Last Changed
January 2023
NATO Update Count
17
NATO Data Quality
5950-01-042-1947 TRANSFORMER,POWER 5950010421947 010421947 1/1
NSN 5950-01-042-1947 (Generic Image) 1/1

5950-01-042-1947 Stock and Availability Marketplace 5950-01-042-1947

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5950-01-042-1947 RQST NE eBay
eBay Updated Every Day
5950-01-042-1947 RQST eBay
Amazon Updated Every Day
5950-01-042-1947 RQST NE Amazon

5950-01-042-1947 Related Documents Related Documents 5950-01-042-1947 1+ Documents (More...)

E 7 Jun 1977 5950-01-042-1946 Power Transformer 20P28CTRNCC: 5 | RNVC: 2 | DAC: E 7 Jun 1977 5950-01-042-1947

5950-01-042-1947 Demil Restrictions 5950-01-042-1947

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-01-042-1947 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-01-042-1947 HTS and ScheduleB Import and Export 5950-01-042-1947

5950-01-042-1947 End Users End Users 5950-01-042-1947

Netherlands (ZN01)
Effective Date:
1 Apr 1991

5950-01-042-1947 Manufacturers Approved Sources 5950-01-042-1947

5950-01-042-1947 Technical Data Datasheet 5950-01-042-1947

Characteristic
Specifications
FIIG
A058B0
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
1.984 Inches Minimum Single Mounting Facility Single Center Group And 2.016 Inches Maximum Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
1.484 Inches Minimum Single Mounting Facility Single Center Group And 1.516 Inches Maximum Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
60.0 Hertz Nominal Single Component
Maximum Transformer Power Rating [ACZF]
30.0 Volt-Ampere Single Component
Mounting Facility Quantity [AKPV]
4 Single Group
Mounting Method [AXGY]
Threaded Hole Single Group
Nominal Thread Size [CQJX]
0.164 Inches Single Group
Inclosure Type [AKNA]
Hermetically Sealed
Input-Output Phase Relationship [ACZC]
Single Phase To Single Phase Single Component
Reliability Indicator [AARG]
Not Established
Overall Height [ABKW]
3.751 Inches Minimum And 3.999 Inches Maximum
Overall Length [ABHP]
2.626 Inches Minimum And 2.718 Inches Maximum
Overall Width [ABMK]
2.094 Inches Minimum And 2.156 Inches Maximum
Winding Function And Quantity [BPLC]
1 Primary Single Component And 1 Secondary Single Component
Winding Operating Current [CRBZ]
3.0 Amperes Ac Nominal Single Component Single Secondary
Winding Operating Voltage [CWJS]
10.00 Ac Volts Nominal Single Component Single Secondary
Winding Operating Voltage [CWJS]
115.00 Ac Volts Nominal Single Component Single Primary
Winding Shielding Method [ACZX]
Internal Shield Grounded To Core Single Component
Terminal Type And Quantity [TTQY]
5 Wire Hook
Thread Series Designator [THSD]
Unc Single Group

5950-01-042-1947 Related Items NATO Stock Numbers Related to 5950-01-042-1947

5950-01-042-1947 Freight Data Freight Information 5950-01-042-1947

5950-01-042-1947 has freight characteristics.. 5950-01-042-1947 has a variance between NMFC and UFC when transported by rail and the description should be consulted.

5950-01-042-1947 Packaging Data Packaging Data 5950-01-042-1947

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
--

Intermediate Pack Level

Quantity of Unit Packs
Container
See Method of Preservation
--