Premium Information is available for this item - Upgrade for $1 a day

5950-00-890-9775

Audio Frequency Transformer

5950008909775 008909775 677-1512-000 ER501

A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices. View more Audio Frequency Transformer

5950-00-890-9775 TRANSFORMER,AUDIO FREQUENCY 5950008909775 008909775

Managed by United States
NSN Created on 10 Apr 1968
Data Last Changed
November 2023
NATO Update Count
12
NATO Data Quality
5950-00-890-9775 TRANSFORMER,AUDIO FREQUENCY 5950008909775 008909775 1/1
NSN 5950-00-890-9775 (Generic Image) 1/1

5950-00-890-9775 Stock and Availability Marketplace 5950-00-890-9775

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5950-00-890-9775 RQST NE eBay
eBay Updated Every Day
5950-00-890-9775 RQST eBay
Amazon Updated Every Day
5950-00-890-9775 RQST NE Amazon

5950-00-890-9775 Related Documents Related Documents 5950-00-890-9775 2+ Documents (More...)

677-1512-000 ER501 A transformer which is designed so that part or all of its range of operating frequencies
RQST NE Updated Every Day 5950-00-890-9775 RQST Updated Every Day 5950-00-890-9775 RQST NE Related Documents
5950-00-890-9775 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-890-9775

5950-00-890-9775 Demil Restrictions 5950-00-890-9775

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-890-9775 is a Audio Frequency Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-890-9775 End Users End Users 5950-00-890-9775

New Zealand (ZE01)
Effective Date:
1 Apr 1991

5950-00-890-9775 Manufacturers Approved Sources 5950-00-890-9775

5950-00-890-9775 Technical Data Datasheet 5950-00-890-9775

Characteristic
Specifications
Body Length [ADAQ]
0.469 Inches Nominal
Body Outside Diameter [ADAR]
0.344 Inches Nominal
Frequency Rating [ACZB]
300.0 Hertz Minimum Single Component And 10.0 Kilohertz Maximum Single Component
Maximum Operating Temp [AEHZ]
105.0 Deg Celsius
Maximum Transformer Power Rating [ACZF]
25.0 Milliwatts Single Component
Mounting Method [AXGY]
Terminal Single Group
Impedance Rating In Ohms [ACYW]
1000.0 Nominal Single Component Single Secondary
Impedance Rating In Ohms [ACYW]
200000.0 Nominal Single Component Single Primary
Inclosure Type [AKNA]
Hermetically Sealed
Reliability Indicator [AARG]
Not Established
Transformer Function [ACYE]
Input
Winding Function And Quantity [BPLC]
1 Primary Single Component And 1 Secondary Single Component
Terminal Type And Quantity [TTQY]
6 Wire Lead

5950-00-890-9775 Similar Items Similar Supply Items to 5950-00-890-9775

5950-00-890-9775 Freight Data Freight Information 5950-00-890-9775

5950-00-890-9775 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-890-9775 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-890-9775 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-890-9775 is not classified as a special type of cargo when transported by water. 5950-00-890-9775 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5950-00-890-9775 Packaging Data Packaging Data 5950-00-890-9775

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
Physical Protection
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
MIL-P-130, Laminated and Creped Wrapping Paper
No Requirement
Not Applicable
Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box