Premium Information is available for this item - Upgrade for $1 a day
5950-00-825-0461
Audio Frequency Transformer
5950008250461 008250461 118796 27530A PA5393 20735M0D 27530
A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices. View more Audio Frequency Transformer
May 2023
17

Marketplace 5950-00-825-0461
Request a Quotation from participating marketplace vendors
Related Documents 5950-00-825-0461 5+ Documents (More...)
5950-00-825-0461 RQST Updated Every Day 5950-00-825-0461 RQST NE Related Documents 5950-00-825-0461
5950-00-825-0461 5950-00-825-0461 Datasheet Management 5950-00-825-0461 RQST Updated Every Day 5950-
Audio Frequency Transformer 5950008250461 Day 5950-00-825-0461 RQST NE Related Documents https/
Audio Frequency Transformer 5950008250461 0461 RQST Restrictions 5998-01-524-6639 DEMIL: P | DEMILI
1PA39630-118796 A specifically designed item pressed or threaded into a lubrication passage, for the
/fsg-47/fsc-4730/it 4730-15-151-4019 Lubrication Fitting 4730151514019151514019 0-1187961PA39630-118796
1PA39630-118796 A specifically designed item pressed or threaded into a lubrication passage, for the
https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-825-0461 Audio Frequency Transformer 5950008250461
Audio Frequency Transformer 5950008250461 Upgrade your Account Upgrade 5998-01-524-6639Circuit
Account Upgrade 6150-01-445-9688Electrical Special Purpose Cable Assembly6150014459688 014459688 008250461
Restrictions 5950-00-825-0461
5950-00-825-0461 is a Audio Frequency Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5950-00-825-0461
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5950-00-825-0461
- US Navy (N9BN)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- KE
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2005
Approved Sources 5950-00-825-0461
- Part Number
- Manufacturer
- Status
- 27530A
- Manufacturer
- 80089 - Emerson Electric Co White-Rodgers (Obsolete)
- Original Design
- Original Design
- 118796
- 06481 - Northrop Grumman Systems Corporation (Active)
- Secondary Buy
- Secondary Buy
- PA5393
- 15634 - Magnetika Inc (Active)
- Secondary Buy
- Secondary Buy
- PA5393
- 80223 - United Transformer Corp (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 20735M0D
- 80089 - Emerson Electric Co White-Rodgers (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 27530
- 11872 - Gulton Industries Inc Standard (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- PA5393
- 03776 - Esco Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5950-00-825-0461
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Body Length [ADAQ]
- 1.500 Inches Maximum
- Body Outside Diameter [ADAR]
- 1.000 Inches Maximum
- Distance Between Mounting Facility Centers [AEJN]
- 1.125 Inches Nominal Single Mounting Facility Single Center Group
- Frequency Rating [ACZB]
- 300.0 Hertz Minimum Single Component And 20.0 Kilohertz Maximum Single Component
- Mounting Facility Quantity [AKPV]
- 2 Single Group
- Mounting Hole Diameter [ABTB]
- 0.125 Inches Nominal Single Group
- Mounting Method [AXGY]
- Flange Single Group And Unthreaded Hole Single Group
- Impedance Rating In Ohms [ACYW]
- 100000.0 Nominal Single Component Single Secondary
- Impedance Rating In Ohms [ACYW]
- 82.0 Nominal Single Component Single Primary
- Inclosure Type [AKNA]
- Fully Inclosed
- Reliability Indicator [AARG]
- Not Established
- Overall Length [ABHP]
- 1.875 Inches Maximum
- Transformer Function [ACYE]
- Input
- Winding Function And Quantity [BPLC]
- 1 Primary Single Component And 1 Secondary Single Component
- Winding Operating Current [CRBZ]
- 50.0 Milliamperes Dc Maximum Single Component Single Primary
- Terminal Type And Quantity [TTQY]
- 5 Tab, Solder Lug
Weapon Systems (WSDC) 5950-00-825-0461
DLA Procurement Analysis 5950-00-825-0461
Management Data 5950-00-825-0461
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5950-00-825-0461


















Freight Information 5950-00-825-0461
5950-00-825-0461 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-825-0461 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-825-0461 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-825-0461 is not classified as a special type of cargo when transported by water. 5950-00-825-0461 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5950-00-825-0461
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
- --
- PPP-B-566 or PPP-B-676, Folding or Setup Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- PPP-B-566 or PPP-B-676, Folding or Setup Box
Contracting Technical Data File (CTDF) 5950-00-825-0461 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: