5950007623152 007623152 08-00183-000 650-1046-000 EP9421
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer
January 2023
20

Marketplace 5950-00-762-3152
Request a Quotation from participating marketplace vendors
Related Documents 5950-00-762-3152 1+ Documents (More...)
RQST NE Updated Every Day 5950-00-762-3152 RQST Updated Every Day 5950-00-762-3152 RQST NE Related
Documents 5950-00-762-3152 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950
Restrictions 5950-00-762-3152
5950-00-762-3152 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5950-00-762-3152
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5950-00-762-3152
- Italy (ZR01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5950-00-762-3152
- Part Number
- Manufacturer
- Status
- 08-00183-000
- Manufacturer
- 00724 - Raytheon Company (Active)
- Primary Buy
- Primary Buy
- 650-1046-000
- 10581 - Standex Electronics, Inc. (Replaced)
- Secondary Buy
- Secondary Buy
- EP9421
- 80103 - Veeco Instruments Inc Lambda Div (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 650-1046-000
- 21908 - Ncr Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5950-00-762-3152
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Body Height [ADAU]
- 6.625 Inches Maximum
- Body Length [ADAQ]
- 5.453 Inches Maximum
- Body Width [ADAT]
- 4.390 Inches Maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 4.546 Inches Minimum Single Mounting Facility Single Center Group And 4.578 Inches Maximum Single Mounting Facility Single Center Group
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 3.421 Inches Minimum Single Mounting Facility Single Center Group And 3.453 Inches Maximum Single Mounting Facility Single Center Group
- Frequency Rating [ACZB]
- 50.0 Hertz Nominal Single Component Or 60.0 Hertz Nominal Single Component
- Maximum Operating Temp [AEHZ]
- 130.0 Deg Celsius
- Maximum Transformer Power Rating [ACZF]
- 300.0 Volt-Ampere Single Component
- Mounting Facility Quantity [AKPV]
- 4 Single Group
- Mounting Method [AXGY]
- Threaded Stud Single Group
- Nominal Thread Size [CQJX]
- 0.312 Inches Single Group
- Inclosure Type [AKNA]
- Fully Inclosed
- Input-Output Phase Relationship [ACZC]
- Single Phase To Single Phase Single Component
- Reliability Indicator [AARG]
- Not Established
- Winding Function And Quantity [BPLC]
- 1 Primary Single Component And 1 Secondary Single Component
- Winding Operating Current [CRBZ]
- 12.6 Amperes Ac Maximum Single Component Single Secondary
- Winding Operating Voltage [CWJS]
- 22.20 Ac Volts Nominal Single Component Single Secondary
- Winding Operating Voltage [CWJS]
- 57.00 Ac Volts Nominal Single Component Single Primary And 420.00 Ac Volts Nominal Single Component Single Primary And 440.00 Ac Volts Nominal Single Component Single Primary And 460.00 Ac Volts Nominal Single Component Single Primary And 480.00 Ac Volts Nominal Single Component Single Primary
- Winding Shielding Method [ACZX]
- Core Grounded Single Component
- Terminal Type And Quantity [TTQY]
- 8 Threaded Stud
- Thread Series Designator [THSD]
- Unc Single Group