Premium Information is available for this item - Upgrade for $1 a day
5950-00-645-0520
Power Transformer
5950006450520 006450520 P6012
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer
![]()
May 2023
10

Marketplace 5950-00-645-0520
Request a Quotation from participating marketplace vendors
Related Documents 5950-00-645-0520 5+ Documents (More...)
-A1 A0062 https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950- 00-645-0520 Power -A1 A0069 - S7232 -P6012
S7232-P6012 https//www.nsnlookup.com 995231558 ,P6012 Probe 5999661469685 661469685,P6012 - S7232-P6012
Cell Probe 5999661469685661469685,P6012 fsg-66/fsc https//www.nsnlookup.com /fsg-70/fsc-7025/it 7025
fsg-59/fsc-5999/it 5999-15-058-6539 Permanent Magnet 5999150586539150586539 6625995231558995231558,P6012
Probe 5999661469685661469685,P6012995231558,P6012 S7232 995231558,P6012 /fsg-66/fsc-6625/uk 6625-99
S7232-P6012 -A1 A0062 https//www.nsnlookup.com S7232-P6012 https S7232-P6012 -A1 A0062 A0062 Test Probe
S7232-P6012 -A1 A0062 https//www.nsnlookup.com S7232-P6012 https//www.nsnlookup.com 995231558 ,P6012
Probe 5999661469685 661469685,P6012 - S7232-P6012 S7232-P6012 5999661469685661469685 https//www.nsnlookup.com
,P6012 S7232-P6012 -A1 A0062 - Italtel Spa ,P6012 995231558,P6012 S7232 995231558,P6012 /fsg-66/fsc-
,P6012 6 20 May 1975 5999-66 au 5999-66-146-9685 Cell https//www.nsnlookup.com - S7232-P6012 S7232-P6012
Restrictions 5950-00-645-0520
5950-00-645-0520 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
End Users 5950-00-645-0520
- US Navy (N9BN)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5950-00-645-0520
- Part Number
- Manufacturer
- Status
- P6012
- Manufacturer
- 80089 - Emerson Electric Co White-Rodgers (Obsolete)
- Original Design
- Original Design
Datasheet 5950-00-645-0520
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Body Height [ADAU]
- 3.375 Inches Nominal
- Body Length [ADAQ]
- 3.375 Inches Nominal
- Body Width [ADAT]
- 2.875 Inches Nominal
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 2.812 Inches Nominal Single Mounting Facility Single Center Group
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 2.250 Inches Nominal Single Mounting Facility Single Center Group
- Frequency Rating [ACZB]
- 60.0 Hertz Nominal Single Component
- Mounting Facility Quantity [AKPV]
- 4 Single Group
- Mounting Method [AXGY]
- Threaded Stud Single Group
- Nominal Thread Size [CQJX]
- 0.138 Inches Single Group
- Inclosure Type [AKNA]
- Partially Inclosed, Double Shell
- Input-Output Phase Relationship [ACZC]
- Single Phase To Single Phase Single Component
- Reliability Indicator [AARG]
- Not Established
- Winding Function And Quantity [BPLC]
- 1 Primary Single Component And 3 Secondary Single Component
- Winding Operating Current [CRBZ]
- 3.0 Amperes Ac Maximum Single Component 1St Secondary
- Winding Operating Current [CRBZ]
- 3.5 Amperes Ac Maximum Single Component 2Nd Secondary
- Winding Operating Current [CRBZ]
- 90.0 Milliamperes Ac Maximum Single Component 3Rd Secondary
- Winding Operating Voltage [CWJS]
- 117.00 Ac Volts Nominal Single Component Single Primary
- Winding Operating Voltage [CWJS]
- 5.00 Ac Volts Nominal Single Component 1St Secondary
- Winding Operating Voltage [CWJS]
- 700.00 Ac Volts Nominal Single Component 3Rd Secondary
- Winding Operating Voltage [CWJS]
- 6.30 Ac Volts Nominal Single Component 2Nd Secondary
- Winding Shielding Method [ACZX]
- Internal Shield Grounded To Inclosure Single Component
- Terminal Type And Quantity [TTQY]
- 11 Wire Lead
- Thread Quantity Per Inch [CMLP]
- 32 Single Group
- Thread Series Designator [THSD]
- Unc Single Group
DLA Procurement Analysis 5950-00-645-0520
Management Data 5950-00-645-0520
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5950-00-645-0520


















Freight Information 5950-00-645-0520
5950-00-645-0520 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-645-0520 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-645-0520 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-645-0520 is not classified as a special type of cargo when transported by water. 5950-00-645-0520 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5950-00-645-0520
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- MIL-P-130, Laminated and Creped Wrapping Paper
- A-A-1051, Paperboard Cushioning
- --
- --
- No special marking
- MIL-P-130, Laminated and Creped Wrapping Paper
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5950-00-645-0520 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: