5950-00-617-9399

Power Transformer

5950006179399 006179399 11430

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer

5950-00-617-9399 TRANSFORMER,POWER 5950006179399 006179399

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
November 2023
NATO Update Count
6
NATO Data Quality
5950-00-617-9399 TRANSFORMER,POWER 5950006179399 006179399 1/1
NSN 5950-00-617-9399 (Generic Image) 1/1

5950-00-617-9399 Stock and Availability Marketplace 5950-00-617-9399

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5950-00-617-9399 RQST NE eBay
eBay Updated Every Day
5950-00-617-9399 RQST eBay
Amazon Updated Every Day
5950-00-617-9399 RQST NE Amazon

5950-00-617-9399 Related Documents Related Documents 5950-00-617-9399 5+ Documents (More...)

Day 5950-00-617-9399 RQST Updated Every Day 5950-00-617-9399 RQST NE Related Documents 5950-00-617-9399
5950006179399006179399 Day 5950-00-617-9399 RQST Updated Every Day 5950-00-617-9399 RQST NE Related
Documents 5950-00-617-9399 5950006179399006179399 Day 5950-00-617-9399 RQST Updated Every Day 5950-00
enable JavaScript in your web browser . 6150-99-110-6543Conductor Bus6150991106543 991106543 400313 11430
-635 https//www.nsnlookup.com 5920050810 011430-635 11430-635 KB -011430A 5920050810 011430-635 11430
-635 KB -011430A-635 KB-11430 https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-617-9399 Power Transformer
Adhesive 8040218826313 218826313,11430 November 2023 NATO MIL-C-11430 https//www.nsnlookup.com -635
//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-617-9399 Power Transformer 5950006179399 006179399 -635
https//www.nsnlookup.com 5920050810 011430-635 11430-635 KB -011430A 5920050810 011430-635 11430 https
for $1 a day Upgrade your Account Upgrade 7330-01-171-4756Cottage Fry Slicer7330011714756 011714756 11430
-635 KB -011430A-635 KB-11430 https//www.nsnlookup.com /fsg-84 https//www.nsnlookup.com 011430- /de 6150
-12-170-2778 Conductor Bus 6150121702778121702778 011430-635 11430-635 KB-011430A-635 KB-11430 https/
JavaScript in your web browser . 4820-12-197-1577Angle Valve4820121971577 121971577 140-323000-000-0 11430
588.90-233013-002 011430 5920050810 011430-635 11430-635 KB-011430A-635 KB-11430-635 KB011430-365 A
https//www.nsnlookup.com /fsg-84 enable JavaScript -635 KB-11430 -635KB011430-365 A 40031311430011430

5950-00-617-9399 Demil Restrictions 5950-00-617-9399

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-617-9399 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-617-9399 End Users End Users 5950-00-617-9399

NASA (G410)
Effective Date:
1 Apr 1991

5950-00-617-9399 Manufacturers Approved Sources 5950-00-617-9399

5950-00-617-9399 Technical Data Datasheet 5950-00-617-9399

Characteristic
Specifications
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
2.120 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
400.0 Hertz Nominal Single Component
Mounting Method [AXGY]
Threaded Stud Single Group
Inclosure Type [AKNA]
Hermetically Sealed
Input-Output Phase Relationship [ACZC]
Single Phase To Single Phase Single Component
Overall Height [ABKW]
3.810 Inches Nominal
Overall Length [ABHP]
2.750 Inches Nominal
Overall Width [ABMK]
2.370 Inches Nominal
Winding Function And Quantity [BPLC]
1 Primary Single Component And 3 Secondary Single Component
Winding Operating Current [CRBZ]
100.0 Milliamperes Ac Maximum Single Component 1St Secondary
Winding Operating Current [CRBZ]
12.0 Amperes Ac Maximum Single Component 3Rd Secondary
Winding Operating Current [CRBZ]
50.0 Milliamperes Ac Maximum Single Component 2Nd Secondary
Winding Operating Voltage [CWJS]
115.00 Ac Volts Nominal Single Component Single Primary
Winding Operating Voltage [CWJS]
2.50 Ac Volts Nominal Single Component 3Rd Secondary
Winding Operating Voltage [CWJS]
500.00 Ac Volts Nominal Single Component 1St Secondary
Winding Operating Voltage [CWJS]
8.00 Ac Volts Nominal Single Component 2Nd Secondary
Winding Shielding Method [ACZX]
External Inclosure Single Component
Terminal Type And Quantity [TTQY]
11 Tab, Solder Lug