5950-00-518-4000

Current Transformer

5950005184000 005184000 B6691 D8255PC6 D8256PC3C 6104-3151443PC3C 6104-3151444PC6 214-6201-776884REV3PC127 S6104-3151444 8255PC6

An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING. View more Current Transformer

5950-00-518-4000 TRANSFORMER,CURRENT 5950005184000 005184000

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
May 2023
NATO Update Count
8
NATO Data Quality
5950-00-518-4000 TRANSFORMER,CURRENT 5950005184000 005184000 1/1
NSN 5950-00-518-4000 (Generic Image) 1/1

5950-00-518-4000 Stock and Availability Marketplace 5950-00-518-4000

Need Help?
Request a Quotation from participating marketplace vendors
FedMallFedMall.mil Updated Every 15 Minutes
5950-00-518-4000 BUY NE FedMallFedMall.mil
eBay Updated Every Day
5950-00-518-4000 RQST NE eBay
eBay Updated Every Day
5950-00-518-4000 RQST eBay
Amazon Updated Every Day
5950-00-518-4000 RQST NE Amazon

5950-00-518-4000 Related Documents Related Documents 5950-00-518-4000 5+ Documents (More...)

| RNVC: 2 | DAC: 4 23 Jan 2002 4530-15-165-1100 https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-518-4000
Current Transformer 5950005184000 005184000 5950-00-518-4000 5950005184000 005184000 is an item
B6691 Van Leeuwen Buizen Nv is an Active Manufacturer with the Cage Code B6691.
Wahidullah Ahmadzai Ltd Frequently Asked Questions (FAQ) for CAGE B6691 What is CAGE Code B6691?
Leeuwen Buizen Nv located at Schaarbeeklei 189, Vilvoorde, 1800, Belgium.Who is CAGE Code B6691?
for $1 a day Upgrade your Account Upgrade 5360-00-422-5541Brush Holder Spring5360004225541 004225541 B6691
5541 Part NumberManufacturerStatusB6691-7 98523 - Jered Llc (Active) Primary Buy RNCC 3 RNVC 2 DAC 5 B6691
to enable JavaScript in your web browser . 5970-00-099-1235Insulation5970000991235 000991235 268002 B6691
RNCC 3 RNVC 2 DAC 5 268002 08219 - Stone Safety Corp (Obsolete) Original Design RNCC 3 RNVC 9 DAC 5 B6691

5950-00-518-4000 Demil Restrictions 5950-00-518-4000

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

5950-00-518-4000 is a Current Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5950-00-518-4000 End Users End Users 5950-00-518-4000

US Navy (N9BN)
Effective Date:
1 Jun 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD

5950-00-518-4000 Manufacturers Approved Sources 5950-00-518-4000

5950-00-518-4000 Technical Data Datasheet 5950-00-518-4000

Characteristic
Specifications
FIIG
A058B0
Body Height [ADAU]
6.500 Inches Nominal
Body Length [ADAQ]
4.500 Inches Nominal
Body Width [ADAT]
3.375 Inches Nominal
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
3.750 Inches Nominal Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
2.000 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
60.0 Hertz Nominal Single Component
Mounting Facility Quantity [AKPV]
4 1St Group
Mounting Method [AXGY]
Flange Single Group And Unthreaded Hole Single Group
Inclosure Type [AKNA]
Open
Input-Output Phase Relationship [ACZC]
Single Phase To Single Phase Single Component
Installation For Which Designed [AFHN]
Indoor Nonportable
Reliability Indicator [AARG]
Not Established
Winding Function And Quantity [BPLC]
1 Primary Single Component And 1 Secondary Single Component
Winding Operating Current [CRBZ]
168.0 Amperes Ac Maximum Single Component Single Primary
Winding Operating Current [CRBZ]
98.0 Milliamperes Ac Maximum Single Component Single Secondary
Winding Operating Voltage [CWJS]
40.00 Ac Pounds Per Hour Wet Single Component Single Primary
Terminal Type And Quantity [TTQY]
7 Terminal Block W/Screws

5950-00-518-4000 Stock, Inventory and Procurement DLA Procurement Analysis 5950-00-518-4000

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5950-00-518-4000 Management Data Management Data 5950-00-518-4000

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5950-00-518-4000 Related Items NATO Stock Numbers Related to 5950-00-518-4000

5950-00-518-4000 Freight Data Freight Information 5950-00-518-4000

5950-00-518-4000 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-518-4000 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-518-4000 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-518-4000 is not classified as a special type of cargo when transported by water. 5950-00-518-4000 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5950-00-518-4000 Packaging Data Packaging Data 5950-00-518-4000

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
Special Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
See Method of Preservation
--

5950-00-518-4000 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5950-00-518-4000 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: