Premium Information is available for this item - Upgrade for $1 a day

5950-00-481-8062

Power Transformer

5950004818062 004818062 100542-030 T164

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer

5950-00-481-8062 TRANSFORMER,POWER 5950004818062 004818062

Managed by United States
NSN Created on 16 Sep 1970
Data Last Changed
May 2023
NATO Update Count
5
NATO Data Quality
5950-00-481-8062 TRANSFORMER,POWER 5950004818062 004818062 1/1
NSN 5950-00-481-8062 (Generic Image) 1/1

5950-00-481-8062 Stock and Availability Marketplace 5950-00-481-8062

Need Help?
Request a Quotation from participating marketplace vendors
FedMallFedMall.mil Updated Every 15 Minutes
5950-00-481-8062 BUY NE FedMallFedMall.mil
eBay Updated Every Day
5950-00-481-8062 RQST NE eBay
eBay Updated Every Day
5950-00-481-8062 RQST eBay
Amazon Updated Every Day
5950-00-481-8062 RQST NE Amazon

5950-00-481-8062 Related Documents Related Documents 5950-00-481-8062 5+ Documents (More...)

100542-030 T164 A transformer consisting of one or more primary winding(s) and one or more secondary
T164 TRANSFORMER,POWER 190 EA NS Request Quotation FedMall Updated Every 15 Minutes 5950-00-481-8062
BUY NE FedMall Updated Every Day 5950-00-481-8062 RQST NE Updated Every Day 5950-00-481-8062 RQST Updated
JavaScript in your web browser . 5999-14-534-3800Electronic Shielding Gasket5999145343800 145343800 T164
in your web browser . 8410-51-000-3332Woman's Raincoat8410510003332 510003332 2004/64 851491313100-T164
Power Transformer 5950004818062 004818062 day Upgrade your Account Upgrade 5950-00-481-8062Power
JavaScript in your web browser . 8410-51-000-1450Woman's Coat8410510001450 510001450 2003/100 858145334100-T164
/50 www.nsnlookup.com /fsg-84/fsc-8410/hu 8410 https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-481-8062
Power Transformer 5950004818062 004818062 534-3800Electronic Shielding Gasket5999145343800 https
in your web browser . 8410-51-000-3332Woman's Raincoat8410510003332 510003332 2004/64 851491313100-T164
Power Transformer 5950004818062 004818062 2004/64 851491313100-T164 Power Transformer 5950004818062004818062
day Upgrade your Account Upgrade 2004/64 851491313100-T164 Power Transformer 5950004818062004818062
JavaScript in your web browser . 8410-51-000-0788Woman's Coat8410510000788 510000788 139/2002 858225335202-T164
//www.nsnlookup.com /fsg-59/fsc-5999/fr 5999-14-534-3800 Electronic Shielding Gasket 5999145343800 T164
-84/fsc-8410/hu 8410-51-000-0788 Woman's Coat 8410510000788510000788 Sys5985145021629 858225335202-T164

5950-00-481-8062 Demil Restrictions 5950-00-481-8062

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-481-8062 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-481-8062 End Users End Users 5950-00-481-8062

US Navy (N9BN)
Effective Date:
1 Jun 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD

5950-00-481-8062 Manufacturers Approved Sources 5950-00-481-8062

5950-00-481-8062 Technical Data Datasheet 5950-00-481-8062

Characteristic
Specifications
FIIG
A058B0
Body Height [ADAU]
2.563 Inches Maximum
Body Length [ADAQ]
3.125 Inches Maximum
Body Width [ADAT]
2.875 Inches Maximum
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
2.500 Inches Nominal Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
1.688 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
50.0 Hertz Minimum Single Component And 60.0 Hertz Maximum Single Component
Maximum Operating Temp [AEHZ]
85.0 Deg Celsius
Mounting Facility Quantity [AKPV]
4 Single Group
Mounting Hole Diameter [ABTB]
0.188 Inches Nominal Single Group
Mounting Method [AXGY]
Flange Single Group And Unthreaded Hole Single Group
Inclosure Type [AKNA]
Partially Inclosed, Double Shell
Input-Output Phase Relationship [ACZC]
Single Phase To Single Phase Single Component
Reliability Indicator [AARG]
Not Established
Winding Operating Current [CRBZ]
10.0 Milliamperes Ac Maximum Single Component 1St Secondary
Winding Function And Quantity [BPLC]
1 Primary Single Component And 3 Secondary Single Component
Winding Operating Current [CRBZ]
500.0 Milliamperes Ac Maximum Single Component 2Nd Secondary
Winding Operating Current [CRBZ]
500.0 Milliamperes Ac Maximum Single Component 3Rd Secondary
Winding Operating Voltage [CWJS]
117.00 Ac Volts Nominal Single Component Single Primary
Winding Operating Voltage [CWJS]
12.60 Ac Volts Nominal Single Component 1St Secondary
Winding Operating Voltage [CWJS]
40.00 Ac Volts Nominal Single Component 2Nd Secondary
Winding Operating Voltage [CWJS]
40.00 Ac Volts Nominal Single Component 3Rd Secondary
Terminal Type And Quantity [TTQY]
10 Wire Lead

5950-00-481-8062 Stock, Inventory and Procurement DLA Procurement Analysis 5950-00-481-8062

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5950-00-481-8062 Management Data Management Data 5950-00-481-8062

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5950-00-481-8062 Similar Items Similar Supply Items to 5950-00-481-8062

5950-00-481-8062 Freight Data Freight Information 5950-00-481-8062

5950-00-481-8062 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-481-8062 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-481-8062 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-481-8062 is not classified as a special type of cargo when transported by water. 5950-00-481-8062 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5950-00-481-8062 Packaging Data Packaging Data 5950-00-481-8062

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
--
--
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5950-00-481-8062 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5950-00-481-8062 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: