Premium Information is available for this item - Upgrade for $1 a day
5950-00-385-8906
Power Transformer
5950003858906 003858906 CS6423 43690 49336 BX-9365 BC6666 213955-1
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer
May 2023
29
Marketplace 5950-00-385-8906
Request a Quotation from participating marketplace vendors
Related Documents 5950-00-385-8906 5+ Documents (More...)
Power Transformer 5950003858906 003858906 https//www.nsnlookup.com /cage Transformer Engineers
Restrictions 5950-00-385-8906
5950-00-385-8906 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
End Users 5950-00-385-8906
- US Air Force (FXGX)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- GTHD
- Poland (WP01)
- Effective Date:
- 1 Mar 2005
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2005
Approved Sources 5950-00-385-8906
- Part Number
- Manufacturer
- Status
- 213955-1
- Manufacturer
- 19790 - Data Products Corp (Obsolete)
- Original Design
- Original Design
- CS6423
- 19193 - Coil Specialty Company, Inc. (Active)
- Secondary Buy
- Secondary Buy
- 43690
- 73386 - Freed Transformer Co (Active)
- Secondary Buy
- Secondary Buy
- 213955-1
- 08742 - Astec America Inc. (Active)
- Secondary Buy
- Secondary Buy
- 49336
- 08742 - Astec America Inc. (Active)
- Secondary Buy
- Secondary Buy
- BX-9365
- 85323 - Baltimore Transformer Co (Active)
- Secondary Buy
- Secondary Buy
- BC6666
- 89870 - Berkshire Transformer (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 213955-1
- 54401 - Transformer Engineers Co A Div Of (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 213955-1
- 58634 - Saga Engineering Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5950-00-385-8906
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Body Height [ADAU]
- 4.880 Inches Minimum And 4.880 Inches Minimum And 4.880 Inches Minimum And 5.000 Inches Maximum5.000 Inches Maximum5.000 Inches Maximum
- Body Length [ADAQ]
- 5.880 Inches Minimum And 5.880 Inches Minimum And 5.880 Inches Minimum And 6.000 Inches Maximum6.000 Inches Maximum6.000 Inches Maximum
- Body Width [ADAT]
- 4.880 Inches Minimum And 4.880 Inches Minimum And 4.880 Inches Minimum And 5.000 Inches Maximum5.000 Inches Maximum5.000 Inches Maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 5.000 Inches Nominal Single Mounting Facility All Center Groupings5.000 Inches Nominal Single Mounting Facility All Center Groupings5.000 Inches Nominal Single Mounting Facility All Center Groupings
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 4.000 Inches Nominal Single Mounting Facility All Center Groupings4.000 Inches Nominal Single Mounting Facility All Center Groupings4.000 Inches Nominal Single Mounting Facility All Center Groupings
- Frequency Rating [ACZB]
- 47.0 Hertz Minimum Single Component And 47.0 Hertz Minimum Single Component And 47.0 Hertz Minimum Single Component And 63.0 Hertz Maximum Single Component63.0 Hertz Maximum Single Component63.0 Hertz Maximum Single Component
- Mounting Facility Quantity [AKPV]
- 8 All Groupings8 All Groupings8 All Groupings
- Mounting Method [AXGY]
- Threaded Hole All Groupingsthreaded Hole All Groupingsthreaded Hole All Groupings
- Nominal Thread Size [CQJX]
- 0.250 Inches All Groupings0.250 Inches All Groupings
- Inclosure Type [AKNA]
- Fully Inclosedfully Inclosedfully Inclosed
- Input-Output Phase Relationship [ACZC]
- Single Phase To Single Phase Single Componentsingle Phase To Single Phase Single Componentsingle Phase To Single Phase Single Component
- Reliability Indicator [AARG]
- Not Establishednot Establishednot Established
- Special Features [FEAT]
- All Voltages Are Stated As Open Circuit; All Currents Are Stated As Rectified; 1 Primary,6 Secondary Windings; Secondaries 5 & 6 Are Rated 115Vrms
- Winding Function And Quantity [BPLC]
- 1 Primary Single Component And 1 Primary Single Component And 1 Primary Single Component And 6 Secondary Single Component6 Secondary Single Component6 Secondary Single Component
- Winding Operating Current [CRBZ]
- 0.6 Amperes Dc Maximum Single Component 3Rd Secondary
- Winding Operating Current [CRBZ]
- 2.0 Amperes Dc Maximum Single Component 1St Secondary
- Winding Operating Current [CRBZ]
- 4.0 Amperes Dc Maximum Single Component 4Th Secondary
- Winding Operating Current [CRBZ]
- 3.0 Amperes Dc Minimum Single Component 2Nd Secondary And 8.0 Amperes Dc Maximum Single Component 2Nd Secondary
- Winding Operating Voltage [CWJS]
- 15.00 Ac Volts Minimum Single Component 3Rd Secondary And 30.00 Ac Volts Maximum Single Component 3Rd Secondary
- Winding Operating Voltage [CWJS]
- 16.80 Ac Volts Minimum Single Component 2Nd Secondary And 33.60 Ac Volts Maximum Single Component 2Nd Secondary
- Winding Operating Voltage [CWJS]
- 48.50 Ac Volts Nominal Single Component 1St Secondary
- Winding Operating Voltage [CWJS]
- 48.50 Ac Volts Nominal Single Component 1St Secondary100.00 Ac Volts Nominal Single Component Single Primary16.80 Ac Volts Minimum Single Component 2Nd Secondary And 33.60 Ac Volts Maximum Single Component 2Nd Secondary
- Winding Operating Voltage [CWJS]
- 9.70 Ac Volts Nominal Single Component 4Th Secondary48.50 Ac Volts Nominal Single Component 1St Secondary
- Winding Shielding Method [ACZX]
- Internal Shield Brought Out To Terminal Single Componentinternal Shield Brought Out To Terminal Single Componentinternal Shield Brought Out To Terminal Single Component
- Terminal Type And Quantity [TTQY]
- 20 Threaded Stud
- Thread Series Designator [THSD]
- Unf All Groupings
Weapon Systems (WSDC) 5950-00-385-8906
DLA Procurement Analysis 5950-00-385-8906
Management Data 5950-00-385-8906
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- V
- The current standard price has been validated.
The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
ZOP or Standard price challenges are permissible but must be supported by adequate justification.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 5950-00-385-8906
Freight Information 5950-00-385-8906
5950-00-385-8906 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-385-8906 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-385-8906 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-385-8906 is not classified as a special type of cargo when transported by water. 5950-00-385-8906 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5950-00-385-8906
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- A-A-203, Kraft Wrapping Paper
- ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
- --
- ASTM-D5118, Type CF, Class Domestic, Corrugated Fiberboard Box
- No special marking
- A-A-203, Kraft Wrapping Paper
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5950-00-385-8906 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: