Premium Information is available for this item - Upgrade for $1 a day
5950-00-318-2364
Power Transformer
5950003182364 003182364 17-04766-1 5752XF
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer
May 2023
8

Marketplace 5950-00-318-2364
Request a Quotation from participating marketplace vendors
Related Documents 5950-00-318-2364 2+ Documents (More...)
BUY NE FedMall Updated Every Day 5950-00-318-2364 RQST NE Updated Every Day 5950-00-318-2364 RQST
Updated Every Day 5950-00-318-2364 RQST NE Related Documents 5950-00-318-2364 2+ Documents ( More...
Power Transformer 5950003182364 003182364 Documents 5950-00-318-2364 2+ Documents ( More... https
Navy (DN)NAConsolidated With 5950-00-318-2364Defense Logistics Agency (DS)IAConsolidated With 5950-00-318-2364
Restrictions 5950-00-318-2364
5950-00-318-2364 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
End Users 5950-00-318-2364
- US Navy (N9BN)
- Effective Date:
- 1 Jul 2005
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
Approved Sources 5950-00-318-2364
- Part Number
- Manufacturer
- Status
- 17-04766-1
- Manufacturer
- 80070 - Lockheed Martin Corporation (Active)
- Original Design
- Original Design
- 17-04766-1
- 97871 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- 5752XF
- 96762 - Electronic Research Associates Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 17-04766-1
- 04614 - Textron Systems Corporation (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5950-00-318-2364
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Body Height [ADAU]
- 2.270 Inches Minimum And 2.270 Inches Minimum And 2.290 Inches Maximum2.290 Inches Maximum
- Body Length [ADAQ]
- 3.740 Inches Minimum And 3.740 Inches Minimum And 3.760 Inches Maximum3.760 Inches Maximum
- Body Width [ADAT]
- 3.370 Inches Minimum And 3.370 Inches Minimum And 3.390 Inches Maximum3.390 Inches Maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 2.802 Inches Minimum Single Mounting Facility Single Center Group And 2.802 Inches Minimum Single Mounting Facility Single Center Group And 2.832 Inches Maximum Single Mounting Facility Single Center Group2.832 Inches Maximum Single Mounting Facility Single Center Group
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 2.240 Inches Minimum Single Mounting Facility Single Center Group And 2.240 Inches Minimum Single Mounting Facility Single Center Group And 2.260 Inches Maximum Single Mounting Facility Single Center Group2.260 Inches Maximum Single Mounting Facility Single Center Group
- Frequency Rating [ACZB]
- 60.0 Hertz Nominal Single Component60.0 Hertz Nominal Single Component
- Maximum Operating Temp [AEHZ]
- 130.0 Deg Celsius130.0 Deg Celsius
- Mounting Facility Quantity [AKPV]
- 4 Single Group4 Single Group
- Mounting Method [AXGY]
- Threaded Stud Single Groupthreaded Stud Single Group
- Nominal Thread Size [CQJX]
- 0.164 Inches Single Group0.164 Inches Single Group
- Inclosure Type [AKNA]
- Hermetically Sealedhermetically Sealed
- Input-Output Phase Relationship [ACZC]
- Single Phase To Single Phase Single Componentsingle Phase To Single Phase Single Component
- Reliability Indicator [AARG]
- Not Establishednot Established
- Winding Function And Quantity [BPLC]
- 1 Primary Single Component And 1 Primary Single Component And 2 Secondary Single Component2 Secondary Single Component
- Winding Operating Current [CRBZ]
- 130.0 Milliamperes Ac Maximum Single Component 2Nd Secondary
- Winding Operating Current [CRBZ]
- 50.0 Milliamperes Ac Maximum Single Component 1St Secondary
- Winding Operating Voltage [CWJS]
- 117.00 Ac Volts Nominal Single Component Single Primary359.00 Ac Volts Nominal Single Component 2Nd Secondary
- Winding Operating Voltage [CWJS]
- 25.10 Ac Volts Nominal Single Component 1St Secondary And 32.90 Ac Volts Nominal Single Component 1St Secondary And 58.00 Ac Volts Nominal Single Component 1St Secondary
- Winding Operating Voltage [CWJS]
- 25.10 Ac Volts Nominal Single Component 1St Secondary And 359.00 Ac Volts Nominal Single Component 2Nd Secondary32.90 Ac Volts Nominal Single Component 1St Secondary And 58.00 Ac Volts Nominal Single Component 1St Secondary
- Winding Shielding Method [ACZX]
- Internal Shield Brought Out To Terminal Single Componentinternal Shield Brought Out To Terminal Single Component
- Terminal Type And Quantity [TTQY]
- 10 Turret
- Thread Series Designator [THSD]
- Unc Single Group
Weapon Systems (WSDC) 5950-00-318-2364
DLA Procurement Analysis 5950-00-318-2364
Management Data 5950-00-318-2364
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5950-00-318-2364


















Freight Information 5950-00-318-2364
5950-00-318-2364 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-318-2364 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-318-2364 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-318-2364 is not classified as a special type of cargo when transported by water. 5950-00-318-2364 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5950-00-318-2364
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
- --
- ASTM-D5118, Type CF, Class Domestic, Corrugated Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5950-00-318-2364 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- Z
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: