Premium Information is available for this item - Upgrade for $1 a day
5950-00-274-2263
Reactor
5950002742263 002742263 278-0385-010 A266
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified). View more Reactor
January 2023
11

Marketplace 5950-00-274-2263
Request a Quotation from participating marketplace vendors
Related Documents 5950-00-274-2263 5+ Documents (More...)
A266 REACTOR 228 EA NS Request Quotation Subscribe to View Vendor Details... 278-0385-010 REACTOR 2 EA
NS Request Quotation 278-0385-010 REACTOR 2 EA NS Request Quotation Updated Every Day 5950-00-274-2263
Day 5998-01 -337-2725 RQST NE Related Documents 5998-01- 93-A266 59/fsc-5998/us 5998-01-337-2725 Every
Day 5998-01 93-A266 59/fsc-5998/us 5998-01-337-2725 Every Day 5998-01-337-2725 Restrictions 5998-01-
4558716 -000DMOD H574-0001-A266 4558716-000DMODD4 7383858-A266D4 H574-0001-A266D4 A hand controlled
4820011037313 ASSEMBLY H 845-4558716 Managed by United https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-274-2263
4558716-000DMOD H574-0001-A266 4558716-000DMODD4 7383858-A266D4 H574-0001-A266D4 A hand controlled device
Reactor 5950002742263 002742263,278-0385-010 Updated Every Day 1560-00-869-4147 RQST NE Updated
-18279 A266-18279 115/380V/5K/50VA/50HZ F829A SMK TLV TRANSFORMERKATALOG A266 Managed by Denmark NSN
A266-18279 115/380V/5K/50VA/50HZ F829A SMK https//www.nsnlookup.com /fsg-55/fsc-5510/uk 5510-99-877-
Restrictions 5950-00-274-2263
5950-00-274-2263 is a Reactor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5950-00-274-2263
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5950-00-274-2263
- Norway (ZT01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Jul 2005
Approved Sources 5950-00-274-2263
- Part Number
- Manufacturer
- Status
- 278-0385-010
- Manufacturer
- 13499 - Rockwell Collins, Inc. (Active)
- Primary Buy
- Primary Buy
- A266
- 81815 - Communication Coil, Inc. (Active)
- Secondary Buy
- Secondary Buy
Datasheet 5950-00-274-2263
- Characteristic
- Specifications
- FIIG
- Specifications
- A058B0
- Terminal Type And Quantity [TTQY]
- 2 Pin
- Rating Method [BKPL]
- Electrical Single Component Single Winding
- Inductance Rating [ACYV]
- 160.00 Microhenries Nominal Single Component Single Winding
- Frequency Rating [ACZB]
- 450.0 Kilohertz Nominal Single Component
- Winding Quantity [AKDX]
- 1 Single Component
- Inductance Type [ACYF]
- Fixed
- Mounting Method [AXGY]
- Terminal Single Group
- Inclosure Type [AKNA]
- Fully Inclosed
- Body Length [ADAQ]
- 0.525 Inches Nominal
- Body Outside Diameter [ADAR]
- 0.400 Inches Nominal
- Reliability Indicator [AARG]
- Not Established
Similar Supply Items to 5950-00-274-2263


















Freight Information 5950-00-274-2263
5950-00-274-2263 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-274-2263 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-274-2263 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-274-2263 is not classified as a special type of cargo when transported by water. 5950-00-274-2263 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5950-00-274-2263
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- Packaging Data does not meet current MIL-STD-2073-1E
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- --
- --
- Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box