Premium Information is available for this item - Upgrade for $1 a day

5950-00-256-8971

Power Transformer

5950002568971 002568971 20504 CE213246 50407

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer

5950-00-256-8971 TRANSFORMER,POWER 5950002568971 002568971

Managed by United States
NSN Created on 24 Mar 1971
Data Last Changed
January 2023
NATO Update Count
15
NATO Data Quality
5950-00-256-8971 TRANSFORMER,POWER 5950002568971 002568971 1/1
NSN 5950-00-256-8971 (Generic Image) 1/1

5950-00-256-8971 Stock and Availability Marketplace 5950-00-256-8971

5950-00-256-8971 Related Documents Related Documents 5950-00-256-8971 5+ Documents (More...)

Manufacturer with the Cage Code 50407.
What is CAGE Code 50407?
50407 refers to Formulabs Industrial Inks Inc Wire Coding Ink And Equipment Systems Div located at 529
6685-19-002-1067 6685190021067 190021067 is an instrument designed to measure air, gas, fluid, and vapor differential by means of a pressure sensitive element(s) which transmits energy, by direct linkage, to the indicating pointer of a scale calibrated to units of pressure. the scale may indicate in units of pressure, quantity, or flow.
5962-01-369-6203 5962013696203 013696203 is a circuit designed to store information and/or coded instructions. item has pins or other connections to install in a computer or computing device. does not include magnetic drums, tapes, punched cards or the like. for items that have portable type connections see memory, portable, solid state.
Request a Quotation from participating marketplace vendors Request Subscribe to View Vendor Details... 50407

5950-00-256-8971 Demil Restrictions 5950-00-256-8971

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-256-8971 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-256-8971 End Users End Users 5950-00-256-8971

Italy (ZR01)
Effective Date:
1 Jul 1997

5950-00-256-8971 Manufacturers Approved Sources 5950-00-256-8971

5950-00-256-8971 Technical Data Datasheet 5950-00-256-8971

Characteristic
Specifications
FIIG
A058B0
Body Height [ADAU]
4.000 Inches Nominal
Body Length [ADAQ]
3.500 Inches Nominal
Body Width [ADAT]
2.875 Inches Nominal
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
2.500 Inches Nominal Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
1.875 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
45.0 Hertz Minimum Single Component And 65.0 Hertz Maximum Single Component
Mounting Facility Quantity [AKPV]
4 Single Group
Mounting Method [AXGY]
Threaded Stud Single Group
Nominal Thread Size [CQJX]
0.164 Inches Single Group
Inclosure Type [AKNA]
Hermetically Sealed
Input-Output Phase Relationship [ACZC]
Single Phase To Single Phase Single Component
Reliability Indicator [AARG]
Not Established
Winding Function And Quantity [BPLC]
2 Primary Single Component And 2 Secondary Single Component
Winding Operating Current [CRBZ]
30.0 Milliamperes Ac Maximum Single Component 1St Secondary
Winding Operating Current [CRBZ]
40.0 Milliamperes Ac Maximum Single Component 2Nd Secondary
Winding Operating Voltage [CWJS]
130.00 Ac Volts Nominal Single Component 1St Secondary
Winding Operating Voltage [CWJS]
130.00 Ac Volts Nominal Single Component 1St Secondary65.00 Ac Volts Nominal Single Component 2Nd Secondary And 115.00 Ac Volts Nominal Single Component All Primary80.00 Ac Volts Nominal Single Component 2Nd Secondary And 150.00 Ac Volts Nominal Single Component 2Nd Secondary And 290.00 Ac Volts Nominal Single Component 2Nd Secondary And 360.00 Ac Volts Nominal Single Component 2Nd Secondary And 375.00 Ac Volts Nominal Single Component 2Nd Secondary And 440.00 Ac Volts Nominal Single Component 2Nd Secondary
Winding Operating Voltage [CWJS]
130.00 Ac Volts Nominal Single Component 1St Secondary65.00 Ac Volts Nominal Single Component 2Nd Secondary And 80.00 Ac Volts Nominal Single Component 2Nd Secondary And 150.00 Ac Volts Nominal Single Component 2Nd Secondary And 290.00 Ac Volts Nominal Single Component 2Nd Secondary And 360.00 Ac Volts Nominal Single Component 2Nd Secondary And 375.00 Ac Volts Nominal Single Component 2Nd Secondary And 440.00 Ac Volts Nominal Single Component 2Nd Secondary
Winding Shielding Method [ACZX]
Internal Shield Grounded To Core Single Component
Terminal Type And Quantity [TTQY]
16 Solder Stud
Thread Quantity Per Inch [CMLP]
32 Single Group
Thread Series Designator [THSD]
Unc Single Group

5950-00-256-8971 Related Items NATO Stock Numbers Related to 5950-00-256-8971

5950-00-256-8971 Freight Data Freight Information 5950-00-256-8971

5950-00-256-8971 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-256-8971 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-256-8971 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-256-8971 is not classified as a special type of cargo when transported by water. 5950-00-256-8971 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5950-00-256-8971 Packaging Data Packaging Data 5950-00-256-8971

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
Packaging Data does not meet current MIL-STD-2073-1E

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
Physical Protection
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box