Premium Information is available for this item - Upgrade for $1 a day

5950-00-119-4608

Power Transformer

5950001194608 001194608 4-1975 55-805702-1 E14959

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE. View more Power Transformer

5950-00-119-4608 TRANSFORMER,POWER 5950001194608 001194608

Managed by United States
NSN Created on 18 Oct 1968
Data Last Changed
May 2023
NATO Update Count
8
NATO Data Quality
5950-00-119-4608 TRANSFORMER,POWER 5950001194608 001194608 1/1
NSN 5950-00-119-4608 (Generic Image) 1/1

5950-00-119-4608 Stock and Availability Marketplace 5950-00-119-4608

Need Help?
Request a Quotation from participating marketplace vendors
FedMallFedMall.mil Updated Every 15 Minutes
5950-00-119-4608 BUY NE FedMallFedMall.mil
eBay Updated Every Day
5950-00-119-4608 RQST NE eBay
eBay Updated Every Day
5950-00-119-4608 RQST eBay
Amazon Updated Every Day
5950-00-119-4608 RQST NE Amazon

5950-00-119-4608 Related Documents Related Documents 5950-00-119-4608 5+ Documents (More...)

CAGE Code 06510) 4 16 Apr 1991 5950-01-297-8812 https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-119-4608
Power Transformer 5950001194608 001194608 (CAGE Code 17474) 5 6 Apr 1988 5950-01-297-8812 Power
(CAGE Code 17474) 5 7 Apr 1989 5950-00-119-4608 Power Transformer 4-1975RNCC: 3 | RNVC: 2 | DAC: 5 18
9 | DAC: 5 26 Jul 1968 5950-00-118-9938 Reactor E30027RNCC: 5 | RNVC: 9 | DAC: 5 21 Oct 1968 5950-00-119-4608
( More... ) https//www.nsnlookup.com /cage Electro Vector Inc (CAGE Code 32712) 21 Oct 1968 5950-00-119-4608
5 6 Apr 1988 5950-01-297-8812 Power Transformer PT 946RNCC: 5 | RNVC: 2 | DAC: 5 7 Apr 1989 5950-00-119-4608

5950-00-119-4608 Demil Restrictions 5950-00-119-4608

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-119-4608 is a Power Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-119-4608 End Users End Users 5950-00-119-4608

US Navy (N9BN)
Effective Date:
1 Jun 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD

5950-00-119-4608 Manufacturers Approved Sources 5950-00-119-4608

5950-00-119-4608 Technical Data Datasheet 5950-00-119-4608

Characteristic
Specifications
FIIG
A058B0
Body Height [ADAU]
2.870 Inches Maximum
Body Length [ADAQ]
3.120 Inches Maximum
Body Width [ADAT]
2.620 Inches Maximum
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
1.940 Inches Nominal Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
1.720 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
50.0 Hertz Minimum Single Component And 400.0 Hertz Maximum Single Component
Maximum Operating Temp [AEHZ]
105.0 Deg Celsius
Mounting Facility Quantity [AKPV]
4 Single Group
Mounting Method [AXGY]
Threaded Hole Single Group
Nominal Thread Size [CQJX]
0.112 Inches Single Group
Inclosure Type [AKNA]
Hermetically Sealed
Input-Output Phase Relationship [ACZC]
Single Phase To Single Phase Single Component
Reliability Indicator [AARG]
Not Established
Winding Function And Quantity [BPLC]
1 Primary Single Component And 2 Secondary Single Component
Winding Operating Current [CRBZ]
300.0 Milliamperes Dc Maximum Single Component 2Nd Secondary
Winding Operating Current [CRBZ]
60.0 Milliamperes Dc Maximum Single Component 1St Secondary
Winding Operating Voltage [CWJS]
420.00 Ac Volts Nominal Single Component 1St Secondary
Winding Operating Voltage [CWJS]
72.00 Ac Volts Nominal Single Component 2Nd Secondary
Winding Shielding Method [ACZX]
Internal Shield Brought Out To Terminal Single Component
Winding Operating Voltage [CWJS]
95.00 Ac Volts Nominal Single Component Single Primary And 135.00 Ac Volts Nominal Single Component Single Primary
Terminal Type And Quantity [TTQY]
9 Tab, Solder Lug
Thread Quantity Per Inch [CMLP]
40 Single Group
Thread Series Designator [THSD]
Unc Single Group

5950-00-119-4608 Stock, Inventory and Procurement DLA Procurement Analysis 5950-00-119-4608

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5950-00-119-4608 Management Data Management Data 5950-00-119-4608

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Navy (DN)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5950-00-119-4608 Related Items NATO Stock Numbers Related to 5950-00-119-4608

5950-00-119-4608 Freight Data Freight Information 5950-00-119-4608

5950-00-119-4608 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-119-4608 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-119-4608 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-119-4608 is not classified as a special type of cargo when transported by water. 5950-00-119-4608 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5950-00-119-4608 Packaging Data Packaging Data 5950-00-119-4608

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5950-00-119-4608 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5950-00-119-4608 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: