5950-00-072-8834

Electrical Coil

5950000728834 000728834 544-6998-003

An item generally consisting of one or more turns of wire or similar conductive material (in special cases it may be considered as a partial turn). It is specifically designed to concentrate magnetic flux generated by the flow of an electric current, to induce in itself an electromotive force, and to add or subtract inductive reactance in a circuit. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). For coils wound on resistors which are designed to be inserted into the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.. View more Electrical Coil

5950-00-072-8834 COIL,ELECTRICAL 5950000728834 000728834

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
January 2023
NATO Update Count
5
NATO Data Quality
5950-00-072-8834 COIL,ELECTRICAL 5950000728834 000728834 1/1
NSN 5950-00-072-8834 (Generic Image) 1/1

5950-00-072-8834 Stock and Availability Marketplace 5950-00-072-8834

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5950-00-072-8834 RQST NE eBay
eBay Updated Every Day
5950-00-072-8834 RQST eBay
Amazon Updated Every Day
5950-00-072-8834 RQST NE Amazon

5950-00-072-8834 Related Documents Related Documents 5950-00-072-8834 1+ Documents (More...)

Every Day 5998-01-021-8834 RQST NE Restrictions https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-072-8834
Electrical Coil 5950000728834 000728834 on 1 Jan 1963 Data Last Changed January 2023 NATO Update
Count 5 NATO Data Quality NSN 5950-00-072-8834 United States (US) 4. 5950-00-072-8834 Marketplace Restrictions

5950-00-072-8834 Demil Restrictions 5950-00-072-8834

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-072-8834 is a Electrical Coil that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-072-8834 HTS and ScheduleB Import and Export 5950-00-072-8834

5950-00-072-8834 End Users End Users 5950-00-072-8834

Republic of Korea (ZH01)
Effective Date:
1 Apr 1991

5950-00-072-8834 Manufacturers Approved Sources 5950-00-072-8834

5950-00-072-8834 Technical Data Datasheet 5950-00-072-8834

Characteristic
Specifications
FIIG
A058B0
Inclosure Type [AKNA]
Fully Inclosed
Inductance Rating [ACYV]
0.35 Microhenries Minimum Single Component Single Winding And 0.60 Microhenries Maximum Single Component Single Winding
Rating Method [BKPL]
Winding Turns Single Component Single Winding
Reliability Indicator [AARG]
Not Established
Turn Quantity [ABHY]
6 Single Component Single Winding
Winding Conductor Size [CQPZ]
0.02535 Inches American Wire Gage Single Component Single Winding
Winding Quantity [AKDX]
1 Single Component

5950-00-072-8834 Related Items NATO Stock Numbers Related to 5950-00-072-8834

5950-00-072-8834 Freight Data Freight Information 5950-00-072-8834

5950-00-072-8834 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063420. A Sub NMFC of Z. It has a NMFC Description of TRANSFORMERS,NOI,OR TRANSFORMER PAR. 5950-00-072-8834 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35355 which rates the freight between FCL and LCL. 5950-00-072-8834 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 595 for ocean manifesting and military sealift. 5950-00-072-8834 is not classified as a special type of cargo when transported by water. 5950-00-072-8834 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5950-00-072-8834 Packaging Data Packaging Data 5950-00-072-8834

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
Packaging Data does not meet current MIL-STD-2073-1E

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
--

Intermediate Pack Level

Quantity of Unit Packs
Container
See Method of Preservation
--