Premium Information is available for this item - Upgrade for $1 a day

5950-00-056-2078

Potential Transformer

5950000562078 000562078 1646735

A transformer designed to connect an electrical instrument to a power line or other high potential alternating current source for the purpose of voltage measurement or control. View more Potential Transformer

5950-00-056-2078 TRANSFORMER,POTENTIAL 5950000562078 000562078

Managed by United States
NSN Created on 1 Jan 1961
Data Last Changed
November 2023
NATO Update Count
6
NATO Data Quality
5950-00-056-2078 TRANSFORMER,POTENTIAL 5950000562078 000562078 1/1
NSN 5950-00-056-2078 (Generic Image) 1/1

5950-00-056-2078 Stock and Availability Marketplace 5950-00-056-2078

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5950-00-056-2078 RQST NE eBay
eBay Updated Every Day
5950-00-056-2078 RQST eBay
Amazon Updated Every Day
5950-00-056-2078 RQST NE Amazon

5950-00-056-2078 Related Documents Related Documents 5950-00-056-2078 1+ Documents (More...)

5950-00-056-2078 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-056-2078
Every Day 5950-00-056-2078 RQST NE Related Documents 5950-00-056-2078 1+ Documents ( More... ) https
//www.nsnlookup.com /fsg-59/fsc-5950/us 5950-00-056-2078 /fsg-59/fsc-5950/us 5950-00-056-2078 Every Day

5950-00-056-2078 Demil Restrictions 5950-00-056-2078

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5950-00-056-2078 is a Potential Transformer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5950-00-056-2078 End Users End Users 5950-00-056-2078

NASA (G900)
Effective Date:
1 Apr 1991

5950-00-056-2078 Manufacturers Approved Sources 5950-00-056-2078

5950-00-056-2078 Technical Data Datasheet 5950-00-056-2078

Characteristic
Specifications
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
9.000 Inches Nominal Single Mounting Facility Single Center Group
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
7.625 Inches Nominal Single Mounting Facility Single Center Group
Frequency Rating [ACZB]
50.0 Hertz Nominal Single Component And 60.0 Hertz Nominal Single Component
Mounting Facility Quantity [AKPV]
4 Single Group
Mounting Hole Diameter [ABTB]
0.438 Inches Nominal Single Group
Mounting Method [AXGY]
Flange Single Group And Unthreaded Hole Single Group
Inclosure Type [AKNA]
Fully Inclosed
Installation For Which Designed [AFHN]
Outdoor Nonportable
Primary To Secondary Turn Ratio [ACZH]
20 To 1 Single Component
Reliability Indicator [AARG]
Not Established
Overall Height [ABKW]
13.562 Inches Nominal
Overall Length [ABHP]
12.500 Inches Nominal
Overall Width [ABMK]
9.875 Inches Nominal
Winding Function And Quantity [BPLC]
1 Primary Single Component And 1 Secondary Single Component
Winding Operating Voltage [CWJS]
120.00 Ac Pounds Per Hour Wet Single Component Single Secondary
Winding Operating Voltage [CWJS]
2.40 Ac Kilovolts Nominal Single Component Single Primary
Winding Power Rating [CRMJ]
500.0 Volts-Amperes Single Component Single Secondary
Winding Shielding Method [ACZX]
External Inclosure Single Component
Terminal Type And Quantity [TTQY]
2 Clamp And 2 Wire Lead

5950-00-056-2078 Related Items NATO Stock Numbers Related to 5950-00-056-2078

5950-00-056-2078 Freight Data Freight Information 5950-00-056-2078

5950-00-056-2078 has freight characteristics.. 5950-00-056-2078 has a variance between NMFC and UFC when transported by rail and the description should be consulted.