Premium Information is available for this item - Upgrade for $1 a day
5945-01-168-5093
Electromagnetic Relay
5945011685093 011685093 MIL-PRF-39016/11 M39016/11-023M MIL-R-39016/11
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING. View more Electromagnetic Relay
January 2023
13

Marketplace 5945-01-168-5093
Request a Quotation from participating marketplace vendors
Related Documents 5945-01-168-5093 5+ Documents (More...)
MIL-R-39016-11 RELAY,ELECTROMAGNETIC 4 EA NS Request Quotation M39016/11-023M RELAY,ELECTROMAGNETIC 1738
M39016/11-023M RELAY,ELECTROMAGNETIC 30 EA NS Request Quotation Updated Every Day 5945-01-168-5093 RQST
MIL-PRF-39016/11 RELAY,ELECTROMAGNETIC 44 EA NS Request Quotation MIL-R-39016-11 RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC 44 EA NS Request Quotation MIL-R-39016-11 RELAY,ELECTROMAGNETIC M39016/11-044L
MIL-R-39016-11 RELAY,ELECTROMAGNETIC 4 EA NS Request Quotation MIL-PRF-39016/11 RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC 4 EA NS Request Quotation MIL-PRF-39016/11 RELAY,ELECTROMAGNETIC M39016/11-
MIL-R-39016-11 RELAY,ELECTROMAGNETIC 4 EA NS Request Quotation MIL-PRF-39016/11 RELAY,ELECTROMAGNETIC
/fsg-59/fsc-5945/us 5945-01-168-5093 Electromagnetic Relay 5945011685093 011685093 M39016/11-023M MIL-R
MIL-PRF-39016/11 RELAY,ELECTROMAGNETIC 44 EA NS Request Quotation MIL-R-39016-11 RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC 44 EA NS Request Quotation MIL-R-39016-11 RELAY,ELECTROMAGNETIC M39016/11-024M
Restrictions 5945-01-168-5093
5945-01-168-5093 is a Electromagnetic Relay that does not have a nuclear hardened feature, but does have another critical feature or features such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5945-01-168-5093
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5945-01-168-5093
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- France (ZF01)
- Effective Date:
- 1 Mar 2000
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
- Italy (ZR01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5945-01-168-5093
- Part Number
- Manufacturer
- Status
- M39016/11-023M
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-PRF-39016/11
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- MIL-R-39016/11
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5945-01-168-5093
- Characteristic
- Specifications
- FIIG
- Specifications
- A03300
- Duty Type [APNP]
- Continuous
- Coil Quantity [APCN]
- 1
- Criticality Code Justification [CRTL]
- Feat
- Environmental Protection [ADZC]
- Hermetic
- Mounting Facility Type And Quantity [AXHR]
- 1 Terminal Single Mounting Facility
- Nonpile-Up Main Contact Arrangement [CRNG]
- 2 Pole, Double Throw, One Position Momentary
- Operating Voltage Rating And Type At Specified Temp [CSXF]
- 26.5 Volts Dc 25 Deg Celsius Single Winding
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 200.0 Milliamperes Dc Inductive Load
- Main Contact Maximum Voltage Rating In Volts [CWAB]
- 28.0 Dc
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 1.0 Amperes Dc Resistive Load
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 100.0 Milliamperes Dc Lamp Load
- Overall Diameter [ADAV]
- 0.370 Inches Maximum
- Overall Height [ABKW]
- 0.375 Inches Maximum
- Special Features [FEAT]
- Failure Rate Level 1.0 Pct; Lead Lg 1.500 In. Min
- Time Delay [CRXH]
- 0.002 Seconds Maximum Fixed Release Time
- Time Delay [CRXH]
- 0.004 Seconds Maximum Fixed Operate Time
- Winding Dc Resistance Rating [APNA]
- 3.3 Kilohms Nominal Single Winding
- Winding Quantity [AKDX]
- 1
- Specification/Standard Data [ZZZK]
- 81349-Mil-R-39016/11 Government Specification
- Terminal Type And Quantity [TTQY]
- 8 Wire Lead All Functions
- Test Data Document [TEST]
- 81349-Mil-R-39016 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
Similar Supply Items to 5945-01-168-5093


















Freight Information 5945-01-168-5093
5945-01-168-5093 has freight characteristics managed by Germany.. 5945-01-168-5093 has a variance between NMFC and UFC when transported by rail and the description should be consulted.