5945-01-075-3886

Electromagnetic Relay

5945010753886 010753886 MIL-PRF-6106 E410-1221 KA-S2F-003 MS27400-11 X22-306-66 MIL-R-6106 10132626

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING. View more Electromagnetic Relay

5945-01-075-3886 RELAY,ELECTROMAGNETIC 5945010753886 010753886

Managed by United States
NSN Created on 20 Apr 1979
Data Last Changed
January 2023
NATO Update Count
35
NATO Data Quality
5945-01-075-3886 RELAY,ELECTROMAGNETIC 5945010753886 010753886 1/1
NSN 5945-01-075-3886 (Generic Image) 1/1

5945-01-075-3886 Stock and Availability Marketplace 5945-01-075-3886

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5945-01-075-3886 RQST NE eBay
eBay Updated Every Day
5945-01-075-3886 RQST eBay
Amazon Updated Every Day
5945-01-075-3886 RQST NE Amazon

5945-01-075-3886 Related Documents Related Documents 5945-01-075-3886 5+ Documents (More...)

MIL-PRF-6106 E410-1221 KA-S2F-003 MS27400-11 X22-306-66 MIL-R-6106 10132626 A relay which is actuated
MS27400-11 RELAY,ELECTROMAGNETIC 2 EA NS Request Quotation 5945-01-075-3886 RELAY,ELECTROMAGNETIC 4 EA
MS27400-11 RELAY,ELECTROMAGNETIC 2 EA NS Request Quotation 5945-01-075-3886 RELAY,ELECTROMAGNETIC 13
MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA
RELAY,ELECTROMAGNETIC 6 EA MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation MIL-R-
Electromagnetic Relay 5945010753886 010753886 E410-1221 KA-S2F-003 MS27400-11 X22-306-66 MIL-R-
KAD2F002 MS27400-3 MIL-R-6106 A relay which is actuated by the effect of a magnetic field developed
MIL-PRF-6106 RELAY,ELECTROMAGNETIC 6 EA NS Request Quotation Subscribe to View Vendor Details...
MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA
MS27400-26 MIL-R-83536/17 M83536/17-004M MS27400-33X MIL-R-6106 A relay which is actuated by the
MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA
Electromagnetic Relay 5945010753886 010753886 E410-1221 KA-S2F-003 MS27400-11 X22-306-66 MIL-R-
MS27400-11 RELAY,ELECTROMAGNETIC 2 EA NS Request Quotation Subscribe to View Vendor Details...
MS27400-11 RELAY,ELECTROMAGNETIC 9 EA NS Request Quotation Subscribe to View Vendor Details...
MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation Subscribe to View Vendor Details...

5945-01-075-3886 Demil Restrictions 5945-01-075-3886

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: U | EDC: | ADPEC:

5945-01-075-3886 is a Electromagnetic Relay that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.

5945-01-075-3886 HTS and ScheduleB Import and Export 5945-01-075-3886

5945-01-075-3886 End Users End Users 5945-01-075-3886

Finland (WF01)
Effective Date:
1 Apr 2011
Spain (YB01)
Effective Date:
1 Apr 1991
Singapore (YJ01)
Effective Date:
1 Apr 1991
Malaysia (YW01)
Effective Date:
1 Aug 1997
Australia (ZA01)
Effective Date:
1 Apr 1991
New Zealand (ZE01)
Effective Date:
1 Apr 1991
France (ZF01)
Effective Date:
1 Mar 1996
Germany (ZG01)
Effective Date:
1 Apr 1991
United Kingdom (ZK01)
Effective Date:
1 Apr 1991
Italy (ZR01)
Effective Date:
1 Apr 1991
Norway (ZT01)
Effective Date:
1 Apr 1991
Greece (ZU01)
Effective Date:
1 Jul 2005
Turkey (ZW01)
Effective Date:
1 Nov 1998

5945-01-075-3886 Manufacturers Approved Sources 5945-01-075-3886

5945-01-075-3886 Technical Data Datasheet 5945-01-075-3886

Characteristic
Specifications
FIIG
A03300
Duty Type [APNP]
Continuous
Arc Quenching Method [APNQ]
Air
Case Material [ADTV]
Metal
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle [CSQJ]
1.446 Inches Nominal Single Mounting Facility
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
0.625 Inches Nominal Single Mounting Facility
Coil Quantity [APCN]
1
Environmental Protection [ADZC]
Hermetic
Features Provided [CBBL]
Polarized
Fragility Factor [AFJN]
Moderately Rugged
Frequency In Hertz [AJSS]
400.0 Nominal
Cubic Measure [CBME]
2.500 Cubic Inches
Mounting Facility Pattern [CQYJ]
Triangle Single Mounting Facility
Mounting Facility Type And Quantity [AXHR]
3 Slotted Hole Single Mounting Facility
Mounting Slot Width [ABTD]
0.150 Inches Nominal Single Mounting Facility
Nonpile-Up Main Contact Arrangement [CRNG]
4 Pole, Double Throw, One Position Momentary
Operating Voltage Rating And Type At Specified Temp [CSXF]
115.0 Volts Ac 25 Deg Celsius Single Winding
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
10.0 Amperes Ac Resistive Load And 10.0 Amperes Dc Resistive Load
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
2.0 Amperes Ac Lamp Load And 2.0 Amperes Dc Lamp Load
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
4.0 Amperes Ac Motor Load And 4.0 Amperes Dc Motor Load
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
8.0 Amperes Ac Inductive Load And 8.0 Amperes Dc Inductive Load
Main Contact Maximum Voltage Rating In Volts [CWAB]
115.0 Ac And 28.0 Dc
Purpose For Which Designed [AKSL]
General
Overall Height [ABKW]
1.420 Inches Maximum
Overall Length [ABHP]
1.718 Inches Maximum
Overall Width [ABMK]
1.025 Inches Maximum
Time Delay [CRXH]
0.02 Seconds Maximum Fixed Operate Time
Time Delay [CRXH]
0.05 Seconds Maximum Fixed Release Time
Winding Quantity [AKDX]
1
Specification/Standard Data [ZZZK]
96906-Ms27400 Government Standard
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
14 Wire Hook All Functions
Test Data Document [TEST]
81349-Mil-R-6106 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).

5945-01-075-3886 Similar Items Similar Supply Items to 5945-01-075-3886

5945-01-075-3886 Freight Data Freight Information 5945-01-075-3886

5945-01-075-3886 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5945-01-075-3886 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5945-01-075-3886 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5945-01-075-3886 is not classified as a special type of cargo when transported by water. 5945-01-075-3886 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5945-01-075-3886 Packaging Data Packaging Data 5945-01-075-3886

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
Electrical Instrument
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
Physical Protection
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
--
--
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
--

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box