5945010275712 010275712 MIL-PRF-6106 KA-D4F-003 MS27400-12 MIL-R-6106

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING. View more Electromagnetic Relay

5945-01-027-5712 RELAY,ELECTROMAGNETIC 5945010275712 010275712

Managed by United States
NSN Created on 18 Sep 1976
Data Last Changed
May 2023
NATO Update Count
30
NATO Data Quality
5945-01-027-5712 RELAY,ELECTROMAGNETIC 5945010275712 010275712 1/1
NSN 5945-01-027-5712 (Generic Image) 1/1

5945-01-027-5712 Stock and Availability Marketplace 5945-01-027-5712

5945-01-027-5712 Related Documents Related Documents 5945-01-027-5712 5+ Documents (More...)

MIL-PRF-6106 KA-D4F-003 MS27400-12 MIL-R-6106 A relay which is actuated by the effect of a magnetic
MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA
RELAY,ELECTROMAGNETIC 6 EA NS Request Quotation MS27400-12 RELAY,ELECTROMAGNETIC 41 EA NS MIL-PRF
MIL-PRF-6106 RELAY 11 EA MIL-R https/ MIL-R -6106 RELAY MIL-PRF-6106 https//www.nsnlookup.com /fsg-59
RELAY 11 EA MIL-PRF-6106 -6106 RELAY MIL-PRF 11 EA MIL-R-6106 11 EA MIL-PRF-6106 -6106 RELAY MIL-PRF
Electromagnetic Relay 5945010275712 010275712 MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request
/11 M6106/11-002 MIL-R-6106/11 A relay which is actuated by the effect of a magnetic field developed
/11 A relay which is actuated by the effect of a magnetic MIL-PRF-6106/11 RELAY,ELECTROMAGNETIC 113
Electromagnetic Relay 5945010275712 010275712 MIL-PRF-6106 https//www.nsnlookup.com /fsg-59 RELAY
/11 M6106/11-001 865536-1 SM15BWD1A MIL-R-6106/11 A relay which is actuated by the effect of a magnetic
/11M6106/11-001865536-1SM15BWD1AMIL-R-6106/11 A relay which is actuated by the effect MIL-PRF-6106
Electromagnetic Relay 5945010275712 010275712 MIL-PRF-6106 https//www.nsnlookup.com /fsg-59 RELAY
MIL-PRF-6106 RELAY,ELECTROMAGNETIC 11 EA NS Request Quotation MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA
-5945/us 5945-01-027-5712 Electromagnetic Relay 5945010275712 010275712 MIL-PRF-6106 RELAY,ELECTROMAGNETIC
11 EA NS Request Quotation MIL-R-6106 RELAY,ELECTROMAGNETIC 11 EA RELAY 11 EA MIL-R https/ MIL-R -6106

5945-01-027-5712 Demil Restrictions 5945-01-027-5712

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: G | EDC: | ADPEC:

5945-01-027-5712 is a Electromagnetic Relay that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item contains gold.

5945-01-027-5712 HTS and ScheduleB Import and Export 5945-01-027-5712

5945-01-027-5712 End Users End Users 5945-01-027-5712

Spain (YB01)
Effective Date:
1 Apr 1991
Singapore (YJ01)
Effective Date:
1 Apr 1991
Malaysia (YW01)
Effective Date:
1 Apr 1991
Australia (ZA01)
Effective Date:
1 Apr 1991
Canada (ZC01)
Effective Date:
1 Apr 1991
France (ZF01)
Effective Date:
1 Oct 1996
Germany (ZG01)
Effective Date:
1 Jan 2015
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
United Kingdom (ZK01)
Effective Date:
1 Apr 1991
Italy (ZR01)
Effective Date:
1 Apr 1991
Greece (ZU01)
Effective Date:
1 Apr 2008
Turkey (ZW01)
Effective Date:
1 Dec 1995

5945-01-027-5712 Manufacturers Approved Sources 5945-01-027-5712

5945-01-027-5712 Technical Data Datasheet 5945-01-027-5712

Characteristic
Specifications
FIIG
A03300
Duty Type [APNP]
Continuous
Arc Quenching Method [APNQ]
Air
Case Material [ADTV]
Metal
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle [CSQJ]
1.446 Inches Nominal Single Mounting Facility
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
0.625 Inches Nominal Single Mounting Facility
Coil Quantity [APCN]
1
Environmental Protection [ADZC]
Hermetic
Fragility Factor [AFJN]
Moderately Rugged
Frequency In Hertz [AJSS]
400.0 Nominal
Cubic Measure [CBME]
2.254 Cubic Inches
Mounting Facility Pattern [CQYJ]
Triangle Single Mounting Facility
Mounting Facility Type And Quantity [AXHR]
3 Slotted Hole Single Mounting Facility
Mounting Slot Width [ABTD]
0.150 Inches Nominal Single Mounting Facility
Nonpile-Up Main Contact Arrangement [CRNG]
4 Pole, Double Throw, One Position Momentary
Operating Voltage Rating And Type At Specified Temp [CSXF]
115.0 Volts Ac 25 Deg Celsius Single Winding
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
10.0 Amperes Ac Resistive Load And 10.0 Amperes Dc Resistive Load
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
2.0 Amperes Ac Lamp Load And 2.0 Amperes Dc Lamp Load
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
4.0 Amperes Ac Motor Load And 4.0 Amperes Dc Motor Load
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
8.0 Amperes Ac Inductive Load And 8.0 Amperes Dc Inductive Load
Main Contact Maximum Voltage Rating In Volts [CWAB]
115.0 Ac And 28.0 Dc
Precious Material [PRMT]
Gold
Precious Material And Location [PMLC]
Terminal Surfaces Gold
Purpose For Which Designed [AKSL]
General
Overall Height [ABKW]
1.280 Inches Maximum
Overall Length [ABHP]
1.718 Inches Maximum
Overall Width [ABMK]
1.025 Inches Maximum
Winding Quantity [AKDX]
1
Specification/Standard Data [ZZZK]
96906-Ms27400 Government Standard
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
14 Pin All Functions
Test Data Document [TEST]
81349-Mil-R-6106 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
Time Delay [CRXH]
0.015 Seconds Maximum Fixed Operate And Release Time

5945-01-027-5712 Similar Items Similar Supply Items to 5945-01-027-5712

5945-01-027-5712 Freight Data Freight Information 5945-01-027-5712

5945-01-027-5712 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5945-01-027-5712 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5945-01-027-5712 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5945-01-027-5712 is not classified as a special type of cargo when transported by water. 5945-01-027-5712 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5945-01-027-5712 Packaging Data Packaging Data 5945-01-027-5712

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
Physical Protection
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
A-A-1898, Grade II, Water Resistant Cellulosic Cushioning
--
PPP-B-566 or PPP-B-676, Folding or Setup Box
--

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box