Premium Information is available for this item - Upgrade for $1 a day

5945-00-856-6759

Electromagnetic Relay

5945008566759 008566759 101698

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING. View more Electromagnetic Relay

5945-00-856-6759 RELAY,ELECTROMAGNETIC 5945008566759 008566759

Managed by United States
NSN Created on 1 Jan 1962
Data Last Changed
January 2023
NATO Update Count
8
NATO Data Quality
5945-00-856-6759 RELAY,ELECTROMAGNETIC 5945008566759 008566759 1/1
NSN 5945-00-856-6759 (Generic Image) 1/1

5945-00-856-6759 Stock and Availability Marketplace 5945-00-856-6759

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5945-00-856-6759 RQST NE eBay
eBay Updated Every Day
5945-00-856-6759 RQST eBay
Amazon Updated Every Day
5945-00-856-6759 RQST NE Amazon

5945-00-856-6759 Related Documents Related Documents 5945-00-856-6759 5+ Documents (More...)

Day 5945-00-856-6759 RQST Updated Every Day 5945-00-856-6759 RQST NE Related Documents 5945-00-856-6759
Relay 5945008566759008566759 Day 5945-00-856-6759 RQST Updated Every Day 5945-00-856-6759 RQST NE Related
Documents 5945-00-856-6759 Relay 5945008566759008566759 Day 5945-00-856-6759 RQST Updated Every Day
to enable JavaScript in your web browser . 5340-99-225-5069Angle Bracket5340992255069 992255069 V.101698
to enable JavaScript in your web browser . 5340-99-225-5069Angle Bracket5340992255069 992255069V.101698
Electromagnetic Relay 5945008566759 008566759 joint formed to enable JavaScript in your web browser
JavaScript in your web browser . 5360-66-044-8191Extension Helical Spring5360660448191 660448191 101698
-00033 101698-00038 A deformable material which prevents the passage of matter through the joint formed
to enable JavaScript in your web browser . 6210-14-281-8976Light Indicator6210142818976 142818976 101698
to enable JavaScript in your web browser . 6210-14-281-8976Light Indicator6210142818976 142818976 101698
https//www.nsnlookup.com /fsg-62/fsc-6210/fr 6210-14 -281-8976 Light Indicator 6210142818976142818976 101698
day Upgrade your Account Upgrade 4320-01-165-8042Axial Piston Pump Parts Kit4320011658042 011658042 101698
Upgrade for $1 a day Upgrade your Account Upgrade 5310-01-527-1871Flat Washer5310015271871 015271871 101698
Flat Washer 5310015271871 015271871,101698 Gasket 5330143374913 143374913,101698-00033 101698 https
$1 a day Upgrade your Account Upgrade 5945-00-856-6759Electromagnetic Relay5945008566759 008566759 101698

5945-00-856-6759 Demil Restrictions 5945-00-856-6759

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: U | EDC: | ADPEC:

5945-00-856-6759 is a Electromagnetic Relay that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.

5945-00-856-6759 HTS and ScheduleB Import and Export 5945-00-856-6759

5945-00-856-6759 End Users End Users 5945-00-856-6759

Canada (ZC01)
Effective Date:
1 Apr 1991

5945-00-856-6759 Manufacturers Approved Sources 5945-00-856-6759

5945-00-856-6759 Technical Data Datasheet 5945-00-856-6759

Characteristic
Specifications
FIIG
A03300
Duty Type [APNP]
Continuous
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
1.375 Inches Nominal Single Mounting Facility
Coil Quantity [APCN]
1
Environmental Protection [ADZC]
Hermetic
Frequency In Hertz [AJSS]
60.0 Nominal
Mounting Facility Pattern [CQYJ]
In-Line Single Mounting Facility
Mounting Facility Type And Quantity [AXHR]
2 Unthreaded Hole Single Mounting Facility
Operating Voltage Rating And Type At Specified Temp [CSXF]
117.0 Volts Ac 25 Deg Celsius Single Winding
Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
2.0 Amperes Dc Resistive Load
Main Contact Maximum Voltage Rating In Volts [CWAB]
26.5 Dc
Overall Height [ABKW]
1.620 Inches Nominal
Overall Length [ABHP]
1.750 Inches Nominal
Overall Width [ABMK]
1.120 Inches Nominal
Pile-Up Main Contact Form Arrangement [AYSC]
2C
Unthreaded Mounting Hole Diameter [AEBV]
0.142 Inches Nominal Single Mounting Facility
Winding Dc Resistance Rating [APNA]
5.0 Kilohms Nominal Single Winding
Winding Quantity [AKDX]
1
Terminal Type And Quantity [TTQY]
8 Pin All Functions
Time Delay [CRXH]
0.005 Seconds Nominal Fixed Operate And Release Time

5945-00-856-6759 Similar Items Similar Supply Items to 5945-00-856-6759

5945-00-856-6759 Freight Data Freight Information 5945-00-856-6759

5945-00-856-6759 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061360. A Sub NMFC of X. It has a NMFC Description of COILS/YOKES FOCUS/DEFLECTION TV. 5945-00-856-6759 is rated as class 85 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34430 which rates the freight between FCL and LCL. 5945-00-856-6759 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5945-00-856-6759 is not classified as a special type of cargo when transported by water. 5945-00-856-6759 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5945-00-856-6759 Packaging Data Packaging Data 5945-00-856-6759

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
Physical Protection
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
--
--
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box