Premium Information is available for this item - Upgrade for $1 a day
5945-00-172-7707
Electromagnetic Relay
5945001727707 001727707 KD4A027
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING. View more Electromagnetic Relay
January 2023
14
Marketplace 5945-00-172-7707
Request a Quotation from participating marketplace vendors
Restrictions 5945-00-172-7707
5945-00-172-7707 is a Electromagnetic Relay that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item contains gold.
Import and Export 5945-00-172-7707
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5945-00-172-7707
- Brazil (YA01)
- Effective Date:
- 1 Jan 2011
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Malaysia (YW01)
- Effective Date:
- 1 Feb 2007
- Portugal (ZP01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5945-00-172-7707
- Part Number
- Manufacturer
- Status
- KD4A027
- Manufacturer
- 58657 - Leach International Corp (Active)
- Primary Buy
- Primary Buy
Datasheet 5945-00-172-7707
- Characteristic
- Specifications
- FIIG
- Specifications
- A03300
- Duty Type [APNP]
- Continuous
- Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle [CSQJ]
- 1.396 Inches Minimum Second Mounting Facility And 1.446 Inches Maximum Second Mounting Facility
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 0.615 Inches Minimum Second Mounting Facility And 0.635 Inches Maximum Second Mounting Facility
- Coil Quantity [APCN]
- 1
- Environmental Protection [ADZC]
- Hermetic
- Features Provided [CBBL]
- Polarized
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [AJSS]
- 400.0 Nominal
- Cubic Measure [CBME]
- 1.061 Cubic Inches
- Mounting Facility Pattern [CQYJ]
- Triangle Second Mounting Facility
- Mounting Facility Type And Quantity [AXHR]
- 1 Plug-In Terminal First Mounting Facility
- Mounting Facility Type And Quantity [AXHR]
- 3 Unthreaded Hole Second Mounting Facility
- Nonpile-Up Main Contact Arrangement [CRNG]
- 4 Pole, Double Throw, One Position Momentary
- Operating Voltage Rating And Type At Specified Temp [CSXF]
- 28.0 Volts Dc 25 Deg Celsius Single Winding
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 10.0 Amperes Ac Resistive Load
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 2.0 Amperes Ac Lamp Load
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 4.0 Amperes Ac Motor Load
- Main Contact Load Current Rating At Maximum Rated Voltage [CTDL]
- 8.0 Amperes Ac Inductive Load
- Main Contact Maximum Voltage Rating In Volts [CWAB]
- 115.0 Ac And 28.0 Dc
- Precious Material And Location [PMLC]
- Terminals Gold
- Precious Material [PRMT]
- Gold
- Purpose For Which Designed [AKSL]
- General
- Overall Height [ABKW]
- 1.010 Inches Maximum
- Overall Length [ABHP]
- 1.025 Inches Maximum
- Overall Width [ABMK]
- 1.025 Inches Maximum
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.155 Inches Minimum Second Mounting Facility And 0.161 Inches Maximum Second Mounting Facility
- Winding Dc Resistance Rating [APNA]
- 280.0 Ohms Minimum Single Winding And 300.0 Ohms Maximum Single Winding
- Winding Quantity [AKDX]
- 1
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 14 Pin All Functions
- Time Delay [CRXH]
- 0.02 Seconds Maximum Fixed Operate And Release Time
NATO Stock Numbers Related to 5945-00-172-7707
Freight Information 5945-00-172-7707
5945-00-172-7707 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5945-00-172-7707 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5945-00-172-7707 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5945-00-172-7707 is not classified as a special type of cargo when transported by water. 5945-00-172-7707 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5945-00-172-7707
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- --
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- --
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box