Premium Information is available for this item - Upgrade for $1 a day

5940-00-193-0718

Terminal Board

5940001930718 001930718 354-11-03-001 H84-1 K52J567-10 601ST3 601-3 PT3-141DW9141 5112-31 3-141W 28003 HV10571 BA10004-22 231B268 3-141 6018151 Y4638R

An item consisting of insulating material, which is specifically designed to have fastened thereon, or on which are fastened terminal(s), such as screws, solder lugs, solder studs, solderless connectors, clips, and the like. It is usually used for junctions or terminations of wire or cable assemblies. It does not include items as defined above with parts, such as resistors and capacitors mounted thereon. Do not use if a more specific name exists, such as FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (as modified); CONNECTOR (as modified). Excludes TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; and CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. For items having printed electrical conductor paths, see PRINTED WIRING BOARD. View more Terminal Board

5940-00-193-0718 TERMINAL BOARD 5940001930718 001930718

Managed by United States
NSN Created on 1 Jan 1961
Data Last Changed
November 2023
NATO Update Count
41
NATO Data Quality
AAQL Style A2 for 5940-00-193-0718 1/1
NSN 5940-00-193-0718 (Identification) 1/1

5940-00-193-0718 Stock and Availability Marketplace 5940-00-193-0718

5940-00-193-0718 Related Documents Related Documents 5940-00-193-0718 5+ Documents (More...)

to enable JavaScript in your web browser . 5940-21-451-0097Terminal Board5940214510097 214510097 Y4638R
DRA34995-3 HV10571 K52J567-10 6018151 3-141 564769 BA10004-22 601-3 601ST3 2Z9403-6 231B268 1012353
Terminal Board 5940001930718 001930718 601ST3601-3 PT3-141DW9141 5112-31 3-141W 28003 HV10571BA10004
to enable JavaScript in your web browser . 4810-15-105-9050Valvola A Sfera4810151059050 151059050 3-141
5 2CR3-141F5A 82647 - Sensata Technologies, Inc (Active) Canceled/Obsolete RNCC 5 RNVC 9 DAC 5 2CR-3-141
https//www.nsnlookup.com /fsg-59/fsc-5940/us 5940-00-193-0718 Terminal Board 5940001930718 001930718
Upgrade for $1 a day Upgrade your Account Upgrade 3445-00-827-1635Table Blade3445008271635 008271635 3-141
5 2CR3-141F5A 82647 - Sensata Technologies, Inc (Active) Canceled/Obsolete RNCC 5 RNVC 9 DAC 5 2CR-3-141
https//www.nsnlookup.com /fsg-59/fsc-5940/us 5940-00-193-0718 Terminal Board 5940001930718 001930718
www.nsnlookup.com /fsg-48/fsc-4810/it 4810-15-105-9050 Valvola A Sfera 4810151059050 151059050,3-141 601ST3
601-3 PT3-141DW9141 5112-31 3-141W 28003 HV10571 BA10004-22 231B268 3-141 Request Quotation 3141 Restrictions
www.nsnlookup.com /fsg-48/fsc-4810/it 4810-15-105-9050 Valvola A Sfera 4810151059050 151059050,3-141 601ST3
601-3 PT3-141DW9141 5112-31 3-141W 28003 HV10571 BA10004-22 231B268 3-141 Request Quotation 3141 Restrictions

5940-00-193-0718 Demil Restrictions 5940-00-193-0718

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: A | EDC: | ADPEC:

5940-00-193-0718 is a Terminal Board that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

5940-00-193-0718 HTS and ScheduleB Import and Export 5940-00-193-0718

5940-00-193-0718 End Users End Users 5940-00-193-0718

NASA (G070)
Effective Date:
1 Apr 1991
Brazil (YA01)
Effective Date:
1 Dec 1999
Spain (YB01)
Effective Date:
1 Feb 1994
France (ZF01)
Effective Date:
1 Jun 2015
Greece (ZU01)
Effective Date:
1 Apr 1991
Turkey (ZW01)
Effective Date:
1 Nov 2005

5940-00-193-0718 Manufacturers Approved Sources 5940-00-193-0718

Part Number
Manufacturer
Status
BA10004-22
71785 - Cinch Connectivity Solutions Inc. (Active)
Primary Buy
354-11-03-001
71785 - Cinch Connectivity Solutions Inc. (Active)
Primary Buy
H84-1
98587 - Ims Engineered Products Llc (Active)
Primary Buy
K52J567-10
24446 - General Electric Company (Active)
Primary Buy
BA10004-22
32869 - O. C. Keckley Company (Active)
Primary Buy
6018151
0B6S1 - International Business Machines Corp (Active)
Primary Buy
601ST3
26405 - Regal Beloit America, Inc (Active)
Secondary Buy
601-3
26405 - Regal Beloit America, Inc (Active)
Secondary Buy
3-141
71785 - Cinch Connectivity Solutions Inc. (Active)
Secondary Buy
PT3-141DW9141
71785 - Cinch Connectivity Solutions Inc. (Active)
Secondary Buy
5112-31
05869 - Raytheon Company (Active)
Secondary Buy
Y4638R
77569 - North American Philips Corp (Active)
Secondary Buy
28003
73891 - Dispute/ Conflict Mediation Services (Active)
Secondary Buy
3-141W
71785 - Cinch Connectivity Solutions Inc. (Active)
Secondary Buy
28003
98410 - Molex-Etc Inc Sub Of Molex Inc (Active)
Canceled/Obsolete
HV10571
21102 - Evans Tempcon Michigan, Llc (Active)
Canceled/Obsolete
BA10004-22
64959 - American Telephone And Telegraph Co (Replaced)
Canceled/Obsolete
231B268
94990 - Motorola Inc. (Replaced)
Canceled/Obsolete
BA10004-22
70408 - At And T Corp (Obsolete)
Canceled/Obsolete
3-141
61864 - Trw Assemblies And Fasteners Group (Obsolete)
Canceled/Obsolete
601-3
83330 - Dialight Corporation (Active)
Canceled/Obsolete
6018151
30874 - International Business Machines (Active)
Canceled/Obsolete
601ST3
83330 - Dialight Corporation (Active)
Canceled/Obsolete
601-3
75832 - Lieberknecht Karl (Obsolete)
Canceled/Obsolete
Y4638R
01349 - Philips Home Products (Obsolete)
Canceled/Obsolete
231B268
1VPW8 - General Dynamics Mission Systems, (Active)
Advisory Reference

5940-00-193-0718 Technical Data Datasheet 5940-00-193-0718

Characteristic
Specifications
FIIG
A011B0
Material [MATT]
Plastic Phenolic Board
Material [MATT]
Copper Alloy Terminals
Surface Treatment [SFTT]
Nickel Terminals
Body Style [AAQL]
Barrier Type
Board Overall Length [ABGN]
2.062 Inches
Board Overall Width [ABGP]
1.125 Inches
Board Overall Height [ABGQ]
0.500 Inches
Board Height Excluding Terminals [ABGR]
0.500 Inches
Base Thickness [ABGS]
0.312 Inches
Terminal Pattern Arrangement [CWLG]
Multi-Row
Terminal Row Quantity [ABCS]
2
Distance Between Terminal Row Centers [ABCU]
0.422 Inches
Center To Center Distance Between Terminals [ABCT]
0.438 Inches
Terminal Design [CWLN]
Linked Nonfeedthru
Nonfeedthru Terminal Type [CRNL]
857 Single
Nonfeedthru Terminal Quantity [CSCS]
3 Single
Terminal Connecting Link Type [CSCR]
2 Single
Terminal Connecting Link Quantity [CQCZ]
3 Single
Board Construction [ABCX]
Solid Construction
Mounting Facility Type And Quantity [AXHR]
4 Unthreaded Hole
Center To Center Distance Between Mounting Facilities Parallel To Length [ABDU]
1.750 Inches
Center To Center Distance Between Mounting Facilities Parallel To Width [ABDV]
0.422 Inches
Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole [ABDW]
0.351 Inches
Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility [ABDX]
0.156 Inches
Mounting Hole Diameter [AAMA]
0.175 Inches
Current Rating In Amps [AMPS]
20.0
Dielectric Withstanding Voltage In Volts [AAPB]
1100.0

5940-00-193-0718 Related Items NATO Stock Numbers Related to 5940-00-193-0718

5940-00-193-0718 Freight Data Freight Information 5940-00-193-0718

5940-00-193-0718 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 000000. A Sub NMFC of X. It has a NMFC Description of NO NMFC FREIGHT DESCRIPTION. 5940-00-193-0718 has not been rated for freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 00000 which rates the freight between FCL and LCL. 5940-00-193-0718 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 772 for ocean manifesting and military sealift. 5940-00-193-0718 is not classified as a special type of cargo when transported by water. 5940-00-193-0718 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.