Premium Information is available for this item - Upgrade for $1 a day

5935-01-144-6585

Electrical Receptacle Connector

5935011446585 011446585 122422-2 L03270 DPD2MA67398-1

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), PRINTED WIRING BOARD, or the like for convenience in joining with another electrical connector(s) or PRINTED WIRING BOARD. It is designed to be mounted on a bulkhead, chassis, panel, wall, PRINTED WIRING BOARD, or the like. Excludes LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (as modified) and SOCKET, PLUG-IN ELECTRONIC COMPONENTS. See also WIRING HARNESS (as modified) and CABLE ASSEMBLY (as modified). For items with termination wires of more than four inches in length, see LEAD ASSEMBLY, ELECTRICAL. For items without inserts, see SHELL, ELECTRICAL CONNECTOR. View more Electrical Receptacle Connector

5935-01-144-6585 CONNECTOR,RECEPTACLE,ELECTRICAL 5935011446585 011446585

Managed by United States
NSN Created on 27 Dec 1982
Data Last Changed
May 2023
NATO Update Count
4
NATO Data Quality
AAQL Style 18G for 5935-01-144-6585 1/1
NSN 5935-01-144-6585 (Identification) 1/1

5935-01-144-6585 Stock and Availability Marketplace 5935-01-144-6585

5935-01-144-6585 Related Documents Related Documents 5935-01-144-6585 2+ Documents (More...)

122422-2 L03270 DPD2MA67398-1 An electrical fitting with electrical contacts constructed to be affixed
RQST NE Related Documents 5935-01-144-6585 3+ Documents ( More... ) https//www.nsnlookup.com /fsg
-59/fsc-5935/us 5935-01-144-6585 Electrical Receptacle Connector 011446585 122422-2L03270DPD2MA67398-
CRITICALITY : | HMIC : | PMIC : | EDC: | ADPEC : 3040 https//www.nsnlookup.com /fsg-59/fsc-5935/us 5935-01-144-6585
Electrical Receptacle Connector 011446585 Upgrade your Account Upgrade 5935-01-144-6585Electrical
Receptacle Connector5935011446585 011446585 122422 /www.nsnlookup.com /fsg-59/fsc-5935/us 5935-01-144

5935-01-144-6585 Demil Restrictions 5935-01-144-6585

DEMIL: F | DEMILI: | CRITICALITY: C | HMIC: P | PMIC: G | EDC: | ADPEC:

5935-01-144-6585 is a Electrical Receptacle Connector that has critical features such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined. This item is a US Munitions List or Commerce Control List Item where the Item Manager, Equipment Specialist or Product Specialist must provide special demilitarization instructions. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item contains gold.

5935-01-144-6585 HTS and ScheduleB Import and Export 5935-01-144-6585

5935-01-144-6585 End Users End Users 5935-01-144-6585

US Navy (N1HE)
Effective Date:
1 May 2003
Former MOE Rule:
N9ND
Supplementary Receivers:
GG

5935-01-144-6585 Manufacturers Approved Sources 5935-01-144-6585

5935-01-144-6585 Technical Data Datasheet 5935-01-144-6585

Characteristic
Specifications
FIIG
A039B0
Center To Center Distance Between Mounting Facilities Parallel To Height [AEBW]
3.235 Inches Minimum And 3.265 Inches Maximum
Connector Locking Method [AFRV]
Screw
Contact Material [CQTZ]
Copper Alloy All Mating Ends Single Contact Grouping
Contact Position Arrangement Style [AFQX]
3 All Mating Ends
Contact Removability [AFQZ]
Removable All Mating Ends Single Contact Grouping
Contact Maximum Current Rating In Amps [AFRC]
80.0 All Mating Ends Single Contact Grouping
Contact Surface Treatment Document And Classification [CRBJ]
Mil-G-45204 Mil Spec Single Treatment Response All Mating Ends Single Contact Grouping
Contact Surface Treatment [CQYH]
Gold All Mating Ends Single Contact Grouping
Criticality Code Justification [CRTL]
Feat
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
2.870 Inches Minimum And 2.880 Inches Maximum
Environmental Protection [ADZC]
Moisture Proof
Body Style [AAQL]
Straight Shape
Mating End Quantity [AFQW]
2
Nominal Thread Size [CQJX]
0.250 Inches
Included Contact Type [CXCL]
Round Socket All Mating Ends Single Contact Grouping
Insert Material [CQZG]
Plastic Diallyl Phthalate All Mating Ends
Polarization Method [AFRN]
Mating End
Precious Material And Location [PMLC]
Contact Surfaces Gold
Precious Material [PRMT]
Gold
Precious Material And Weight [PMWT]
0.030 Gold Grains, Troy
Shell Material [CSPT]
Aluminum Alloy
Shell Surface Treatment Document And Classification [CTBC]
Qq-P-416 Ty 2,Cl 3 Fed Spec Single Treatment Response
Shell Surface Treatment [CSWM]
Cadmium
Shell Type [AFRT]
Solid
Overall Height [ABKW]
3.922 Inches Minimum And 3.953 Inches Maximum
Overall Length [ABHP]
1.504 Inches Maximum
Overall Width [ABMK]
3.359 Inches Minimum And 3.391 Inches Maximum
Special Features [FEAT]
Item Must Comply With Requirements Of Desc Production Standard No. L03270; For Navy Nuclear Propulsion Plant Products Only
Threaded Device Type [AFQR]
Coupling Facility
Unthreaded Mounting Hole Diameter [AEBV]
0.144 Inches Nominal
Terminal Location [CQTM]
Back All Mating Ends Single Contact Grouping
Terminal Type [CSCF]
Crimp All Mating Ends Single Contact Grouping
Thread Class [AAJD]
2A
Thread Direction [AAJF]
Right-Hand
Thread Series Designator [THSD]
Unf
Thread Quantity Per Inch [CMLP]
28

5935-01-144-6585 Management Data Management Data 5935-01-144-6585

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Navy (DN)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
1H
Consumable material assigned to NAVICP MECH for inventory management
Naval Inventory Control Point, Mechanicsburg
Special Material ID:
X3
Nuclear Reactor Plant (NRP) material under the technical cognizance of the NAVSEA 08 special designed, manufactured and/or treated for use in a NRP or controls thereof. This category includes all other NRP items which are not coded X2 or X4.
Issue, Repair, Requisition Restriction Code:
BL
Submit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipment
Special Material Content:
9
Non-Hazardous or Non-Sensitive Item

5935-01-144-6585 Similar Items Similar Supply Items to 5935-01-144-6585

5935-01-144-6585 Freight Data Freight Information 5935-01-144-6585

5935-01-144-6585 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061680. A Sub NMFC of Z. It has a NMFC Description of ELEC WIRING PLUGS ETC. 5935-01-144-6585 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34570 which rates the freight between FCL and LCL. 5935-01-144-6585 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5935-01-144-6585 is not classified as a special type of cargo when transported by water. 5935-01-144-6585 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5935-01-144-6585 Packaging Data Packaging Data 5935-01-144-6585

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
Packaging Data does not meet current MIL-STD-2073-1E
Storage Environment
Heated General Purpose – Heated 40 F and above

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
Special Requirements – see Specific Instructions or Drawings provided
Special Requirements. See Specific Instructions or Drawings Provided
Special Requirements. See Specific Instructions or Drawings Provided
Special requirement – See specific instructions or drawings provided
Special requirements

Intermediate Pack Level

Quantity of Unit Packs
Container
--
No Requirement