Premium Information is available for this item - Upgrade for $1 a day
5930-01-187-7470
Thermostatic Switch
5930011877470 011877470 MIL-PRF-24236/1 M24236/1-0370 578800-001 M1200160151 MILS24236
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified). View more Thermostatic Switch
June 2023
8

Marketplace 5930-01-187-7470
Request a Quotation from participating marketplace vendors
Related Documents 5930-01-187-7470 5+ Documents (More...)
MIL-PRF-24236/1 SWITCH,THERMOSTATIC 5 EA NS Request Quotation Updated Every Day 5930-01-187-7470 RQST
NE Updated Every Day 5930-01-187-7470 RQST Updated Every Day 5930-01-187-7470 RQST NE Related Documents
MIL-PRF-24236/1 M24236/1-0370 578800 https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-823-0817 Thermostatic
MIL-PRF-24236/1 M24236/1-0370 578800 https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-823-0817 Thermostatic
MIL-PRF-24236/1 M24236/1-0370 578800 https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-823-0817 Thermostatic
9174Overvoltage Absorber5920011489174 011489174 578800 https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-01-187-7470
Thermostatic Switch 5930011877470 011877470 www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-823-0817
Thermostatic 9174Overvoltage Absorber5920011489174 011489174 www.nsnlookup.com /fsg-59/fsc-5930/us 5930-01-187-7470
MILS24236-1 SWITCH,THERMOSTATIC RQST NS Request Quotation Subscribe to View Vendor Details...
MILS24236-1 SWITCH,THERMOSTATIC RQST NS Request Quotation M24236/1-1205 MILS24236 Thermostatic Switch
Restrictions 5930-01-187-7470
5930-01-187-7470 is a Thermostatic Switch that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5930-01-187-7470
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5930-01-187-7470
- US Air Force (FXGX)
- Effective Date:
- 1 Nov 2005
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Nov 2005
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
- Brazil (YA01)
- Effective Date:
- 1 May 2008
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Jan 2009
- Turkey (ZW01)
- Effective Date:
- 1 Jan 2009
Approved Sources 5930-01-187-7470
- Part Number
- Manufacturer
- Status
- M24236/1-0370
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-PRF-24236/1
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- MILS24236
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 578800-001
- 02294 - Marathonnorco Aerospace, Inc. (Active)
- Transferred
- Transferred
- M1200160151
- 82647 - Sensata Technologies, Inc. (Active)
- Transferred
- Transferred
Datasheet 5930-01-187-7470
- Characteristic
- Specifications
- FIIG
- Specifications
- A048B0
- Body Diameter [ABPM]
- 0.640 Inches Maximum
- Body Height [ADAU]
- 0.350 Inches Minimum And 0.395 Inches Maximum
- Contact Action Stimulus [CQGB]
- Increase
- Contact Adjustability [CTYC]
- Actuation Point Not Adjustable And Deactuation Point Not Adjustable
- Contact Load Current Rating [CTHF]
- 2.0 Amperes Resistive Load First Voltage And 1.0 Amperes Inductive Load First Voltage And 500.0 Milliamperes Lamp Load First Voltage
- Contact Load Current Rating [CTHF]
- 5.0 Amperes Resistive Load Second Voltage And 2.5 Amperes Inductive Load Second Voltage And 1.0 Amperes Lamp Load Second Voltage
- Contact Stimulus Rating [CTYX]
- 200.00 Actuation Point Nominal Degrees Fahrenheit And 160.00 Deactuation Point Nominal Degrees Fahrenheit And 40.00 Differential Point Nominal Degrees Fahrenheit
- Contact Voltage Rating In Volts [CTZB]
- 115.0 Ac At Sea Level First Voltage
- Contact Voltage Rating In Volts [CTZB]
- 28.0 Dc At Sea Level Second Voltage
- Distance Between Mounting Facility Centers [AEJN]
- 0.937 Inches Nominal
- Frequency In Hertz [FREQ]
- 60.0 First Voltage
- Media For Which Designed [MEDA]
- Gas Or Liquid
- Mounting Facility Pattern [CQYJ]
- Two Position In-Line
- Mounting Method [AXGY]
- Bracket And Slot And Unthreaded Hole
- Mounting Slot Width [ABTD]
- 0.140 Inches Nominal
- Nonpile-Up Contact Arrangement [CRLD]
- 1 Pole, Single Throw, Normally Open, Momentary Action
- Overall Length [ABHP]
- 1.200 Inches Minimum And 1.260 Inches Maximum
- Style Designator [STYL]
- Disc W/Flange
- Overall Height [ABKW]
- 0.708 Inches Nominal
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.140 Inches Nominal
- Specification/Standard Data [ZZZK]
- 81349-Mils24236/1 Government Specification
- Temp Sensing Element Type [AKBY]
- Internal Sensor
- Terminal Type [CSCF]
- Tab, Solder Lug
- Test Data Document [TEST]
- 81349-Mils24236 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
DLA Procurement Analysis 5930-01-187-7470
Management Data 5930-01-187-7470
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5930-01-187-7470


















Freight Information 5930-01-187-7470
5930-01-187-7470 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5930-01-187-7470 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5930-01-187-7470 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5930-01-187-7470 is not classified as a special type of cargo when transported by water. 5930-01-187-7470 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5930-01-187-7470
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5930-01-187-7470 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: