Premium Information is available for this item - Upgrade for $1 a day
5930-01-103-0376
Liquid Level Switch
5930011030376 011030376 118793 A3771
A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY. View more Liquid Level Switch
![]()
June 2023
8

Marketplace 5930-01-103-0376
Request a Quotation from participating marketplace vendors
Related Documents 5930-01-103-0376 5+ Documents (More...)
BUY NE FedMall Updated Every Day 5930-01-103-0376 RQST NE Updated Every Day 5930-01-103-0376 RQST Updated
Every Day 5930-01-103-0376 RQST NE Related Documents 5930-01-103-0376 5+ Documents ( More... ) https
1PA39630-118793 Three or more metallic strands twisted helically together around a fiber, metallic,
Liquid Level Switch 5930011030376 011030376 5930-01-103-0376 5+ Documents ( More... ) https https
JavaScript in your web browser . 5935-34-030-7847Electrical Plug Connector5935340307847 340307847 118793
RQST NE Related Documents https//www.nsnlookup.com https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-01-103-0376
https//www.nsnlookup.com /fsg-40/fsc-4010/it 4010-15-151-4016 Wire Rope 4010151514016 151514016,0-118793
1PA39630-118793 Three or more metallic strands twisted helically together around a fiber, metallic,
www.nsnlookup.com /fsg-58/fsc-5895/us 5895-01-466-8219 Quad 5895014668219014668219,HYV254M2B0D1 HYV254M2B0D1002-118793
Restrictions Approved Sources Datasheet Management https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-01-103-0376
Restrictions 5930-01-103-0376
5930-01-103-0376 is a Liquid Level Switch that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5930-01-103-0376
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5930-01-103-0376
- US Air Force (FXGX)
- Effective Date:
- 1 Nov 2005
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Nov 2005
- Supplementary Collaborators:
- HD
Approved Sources 5930-01-103-0376
- Part Number
- Manufacturer
- Status
- 118793
- Manufacturer
- 04034 - Setra Systems, Inc. (Active)
- Primary Buy
- Primary Buy
- A3771
- 04034 - Setra Systems, Inc. (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5930-01-103-0376
- Characteristic
- Specifications
- FIIG
- Specifications
- T109-D
- Electrical Connection Type [AGBD]
- Cable
- Ac Voltage Rating [ACYN]
- 120.0 Volts Maximum
- Ac Voltage Rating [ACYN]
- 240.0 Volts Maximum
- Ac Voltage Rating [ACYN]
- 50.0 Volts Maximum
- Actuation Method [AFLW]
- Buoyancy
- Contact Arrangement [BJKD]
- Spst,Normally Closed,Dry
- Current Rating At Maximum Rated Voltage [APGW]
- 0.04 Amperes Resistive Load
- Dc Voltage Rating [ACYR]
- 50.0 Volts Maximum
- Dc Voltage Rating [ACYR]
- 120.0 Volts Maximum
- Dc Voltage Rating [ACYR]
- 240.0 Volts Maximum
- Float Effective Travel [BJKN]
- 0.250 Inches Nominal
- Float Quantity [AWAE]
- 1
- Frequency Rating [ACZB]
- 60.0 Hertz Nominal
- Maximum Current Rating [BJKC]
- 0.08 Amperes Resistive Load
- Mounting Dimensions [BJKP]
- Mtd By One 1.250 In. Npt Plug
- Mounting Method [AXGY]
- Thread
- Mounting Position [BBJX]
- Vertical
- Operating Temp Rating [AWTN]
- 0.0 Deg Fahrenheit Minimum And 230.0 Deg Fahrenheit Maximum
- Internal Battery Accommodation [ALSF]
- Not Included
- Liquid Type For Which Designed [BJKH]
- Sea Water And Water
- Power Cable Length [ABJP]
- 24.000 Inches Nominal
- Relay [BJKG]
- Not Included
- Overall Diameter [ADAV]
- 1.250 Inches Nominal
- Overall Length [ABHP]
- 20.000 Inches Nominal
- Phase [FAAZ]
- Single
- Voltage Rating At Maximum Rated Current [APGY]
- 120.0 Volts
- Tank Insertion Length [BJKQ]
- 15.000 Inches Nominal
DLA Procurement Analysis 5930-01-103-0376
Management Data 5930-01-103-0376
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Mar 2023
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- Oct 2022
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Oct 2021
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- Oct 2020
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- N
- X
- Formerly 6680
- X
- Defense Logistics Agency (DS)
- I
- X
- Formerly 6680
- X
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5930-01-103-0376


















Freight Information 5930-01-103-0376
5930-01-103-0376 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5930-01-103-0376 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. 5930-01-103-0376 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5930-01-103-0376 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5930-01-103-0376 is not classified as a special type of cargo when transported by water. 5930-01-103-0376 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5930-01-103-0376
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5930-01-103-0376 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: