Premium Information is available for this item - Upgrade for $1 a day
5930-00-911-8803
Thermostatic Switch
5930009118803 009118803 FE650-0002-100N 689/1/05569/000 ITEM 079 26141-868-00-5/079 42211-002-00-3 VE3101 26141-868-00-5 ITEM 079 42211-002-3 689/1/05569/000/079 ES6592-01
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified). View more Thermostatic Switch
November 2023
25
Marketplace 5930-00-911-8803
Request a Quotation from participating marketplace vendors
Related Documents 5930-00-911-8803 5+ Documents (More...)
$1 a day Upgrade your Account Upgrade 5930-99-652-3258Thermostatic Switch5930996523258 996523258 VE3101
https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-911-8803 Thermostatic Switch 5930009118803 009118803
$1 a day Upgrade your Account Upgrade 5930-99-543-8541Thermostatic Switch5930995438541 995438541 VE3101
https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-911-8803 Thermostatic Switch 5930009118803 009118803
$1 a day Upgrade your Account Upgrade 5930-99-652-3258Thermostatic Switch5930996523258 996523258 VE3101
https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-911-8803 Thermostatic Switch 5930009118803 009118803
Thermostatic Switch 5930009118803 009118803, Switch5930009118803 009118803 FE650-0002-100N 689/
1/05569/000 ITEM 079 26141-868-00-5/079 42211-002-00-3 VE3101 VE3101 SWITCH,THERMOSTATIC 3 EA NS Request
Thermostatic Switch 5930009118803 009118803, 5930-00-911-8803 5930009118803 009118803 is a switch
Restrictions 5930-00-911-8803
5930-00-911-8803 is a Thermostatic Switch that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a confirmed Commerce Control List Item (CCLI). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item contains gold.
Import and Export 5930-00-911-8803
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5930-00-911-8803
- US Air Force (FXGX)
- Effective Date:
- 1 Jul 2005
- US Navy (N9BN)
- Effective Date:
- 1 Jul 2005
- Supplementary Collaborators:
- HDKEJB
- Austria (WB)
- Austria (WB01)
- Effective Date:
- 1 Feb 2005
- Brazil (YA01)
- Effective Date:
- 1 Jan 2017
- Spain (YB)
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Israel (YD01)
- Effective Date:
- 1 Aug 2016
- United Kingdom (ZK)
- United Kingdom (ZK01)
- Effective Date:
- 1 Dec 2009
- United States of America (ZZ)
Approved Sources 5930-00-911-8803
- Part Number
- Manufacturer
- Status
- VE3101
- Manufacturer
- 93929 - Spx Corporation (Obsolete)
- Original Design
- Original Design
- 26141-868-00-5 ITEM 079
- K4556 - British Aerospace Defence Systems (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 26141-868-00-5/079
- K4556 - British Aerospace Defence Systems (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 42211-002-00-3
- K4556 - British Aerospace Defence Systems (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 42211-002-3
- K4556 - British Aerospace Defence Systems (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- FE650-0002-100N
- K6894 - Bae Systems, Ro Defence (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- ES6592-01
- 20418 - Drs Sustainment Systems, Inc. (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 689/1/05569/000 ITEM 079
- K4556 - British Aerospace Defence Systems (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 689/1/05569/000/079
- K4556 - British Aerospace Defence Systems (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- VE3101
- 20418 - Drs Sustainment Systems, Inc. (Replaced)
- Obsolete Drawing
- Obsolete Drawing
- FE650-0002-100N
- K3743 - Bae Systems Global Combat Systems (Active)
- Advisory Reference
- Advisory Reference
- 689/1/05569/000 ITEM 079
- KC1M9 - Bae Systems Maritime Services (Active)
- Advisory Reference
- Advisory Reference
- 26141-868-00-5/079
- KC1M9 - Bae Systems Maritime Services (Active)
- Advisory Reference
- Advisory Reference
- 42211-002-00-3
- KC1M9 - Bae Systems Maritime Services (Active)
- Advisory Reference
- Advisory Reference
- VE3101
- 98255 - Drs Sustainment Systems Inc (Active)
- Advisory Reference
- Advisory Reference
- 26141-868-00-5 ITEM 079
- KC1M9 - Bae Systems Maritime Services (Active)
- Advisory Reference
- Advisory Reference
- 42211-002-3
- KC1M9 - Bae Systems Maritime Services (Active)
- Advisory Reference
- Advisory Reference
- 689/1/05569/000/079
- KC1M9 - Bae Systems Maritime Services (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5930-00-911-8803
- Characteristic
- Specifications
- FIIG
- Specifications
- A048B0
- Body Height [ADAU]
- 0.500 Inches Maximum
- Body Length [ADAQ]
- 0.750 Inches Maximum
- Body Width [ADAT]
- 0.327 Inches Nominal
- Contact Action Stimulus [CQGB]
- Increase
- Contact Adjustability [CTYC]
- Actuation Point Not Adjustable And Deactuation Point Not Adjustable
- Contact Load Current Rating [CTHF]
- 1.0 Amperes Resistive Load Second Voltage
- Contact Load Current Rating [CTHF]
- 2.0 Amperes Resistive Load First Voltage
- Contact Stimulus Rating [CTYX]
- 75.00 Actuation Point Nominal Degrees Celsius
- Contact Voltage Rating In Volts [CTZB]
- 115.0 Ac At Sea Level First Voltage
- Contact Voltage Rating In Volts [CTZB]
- 32.0 Dc At Sea Level Second Voltage
- Distance Between Mounting Facility Centers [AEJN]
- 1.000 Inches Nominal
- Features Provided [CBBL]
- Hermetically Sealed Case
- Hazardous Locations/Environmental Protection [ABFE]
- Vibration Resistant
- Media For Which Designed [MEDA]
- Solid
- Mounting Facility Pattern [CQYJ]
- Two Position In-Line
- Mounting Method [AXGY]
- Bracket
- Nonpile-Up Contact Arrangement [CRLD]
- 1 Pole, Double Throw, One Position Momentary
- Overall Length [ABHP]
- 1.266 Inches Maximum
- Style Designator [STYL]
- Rectangular W/Bracket
- Precious Material And Location [PMLC]
- Contacts Gold And Contacts Silver And Contacts Platinum
- Overall Height [ABKW]
- 0.688 Inches Maximum
- Overall Width [ABMK]
- 0.391 Inches Maximum
- Specification/Standard Data [ZZZK]
- 20418-Es659201 Manufacturers Specification Control
- Temp Sensing Element Type [AKBY]
- Internal Sensor
- Terminal Type [CSCF]
- Tab, Solder Lug
Weapon Systems (WSDC) 5930-00-911-8803
DLA Procurement Analysis 5930-00-911-8803
Management Data 5930-00-911-8803
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 5930-00-911-8803
Freight Information 5930-00-911-8803
5930-00-911-8803 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063160. A Sub NMFC of Z. It has a NMFC Description of SWITCH BOXES/ELEC ENCLOSURES. 5930-00-911-8803 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35205 which rates the freight between FCL and LCL. 5930-00-911-8803 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5930-00-911-8803 is not classified as a special type of cargo when transported by water. 5930-00-911-8803 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Contracting Technical Data File (CTDF) 5930-00-911-8803 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- L
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: