Premium Information is available for this item - Upgrade for $1 a day

5930-00-681-0917

Sensitive Switch

5930006810917 006810917 BA2V22A2

A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. Includes membrane switch. Excludes SWITCH, FLEXIBLE; SWITCH, PRESSURE; and SWITCH, THERMOSTATIC. View more Sensitive Switch

5930-00-681-0917 SWITCH,SENSITIVE 5930006810917 006810917

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
November 2023
NATO Update Count
6
NATO Data Quality
5930-00-681-0917 SWITCH,SENSITIVE 5930006810917 006810917 1/1
NSN 5930-00-681-0917 (Generic Image) 1/1

5930-00-681-0917 Stock and Availability Marketplace 5930-00-681-0917

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5930-00-681-0917 RQST NE eBay
eBay Updated Every Day
5930-00-681-0917 RQST eBay
Amazon Updated Every Day
5930-00-681-0917 RQST NE Amazon

5930-00-681-0917 Related Documents Related Documents 5930-00-681-0917 1+ Documents (More...)

RQST NE Updated Every Day 5930-00-681-0917 RQST Updated Every Day 5930-00-681-0917 RQST NE Related Documents
5930-00-681-0917 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-681-0917
Day 5930-00-681-0917 RQST NE Related Documents 5930-00-681-0917 1+ Documents ( More... ) https//www.nsnlookup.com

5930-00-681-0917 Demil Restrictions 5930-00-681-0917

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5930-00-681-0917 is a Sensitive Switch that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5930-00-681-0917 End Users End Users 5930-00-681-0917

NASA (G120)
Effective Date:
1 Apr 1991

5930-00-681-0917 Manufacturers Approved Sources 5930-00-681-0917

5930-00-681-0917 Technical Data Datasheet 5930-00-681-0917

Characteristic
Specifications
Actuator Free Position Height [AFUU]
1.415 Inches Maximum
Actuator Movement [CXQQ]
0.250 Pretravel Inches Maximum And 0.031 Overtravel Inches Minimum And 0.047 Differential Inches Nominal
Actuator Style [AFUQ]
Roller Arm
Body Height [ADAU]
0.797 Inches Nominal
Body Length [ADAQ]
1.938 Inches Nominal
Body Style [AAQL]
Hole Mounted
Body Width [ADAT]
0.688 Inches Nominal
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
1.000 Inches Nominal
Contact Load Current Rating At Maximum Rated Voltage [CXQR]
250.000 Milliamperes Resistive Dc And 20.000 Amperes Resistive Ac
Maximum Voltage Rating In Volts [AFXE]
460.0 Ac And 250.0 Dc
Nonpile-Up Contact Arrangement [CRLD]
1 Pole, Double Throw, Both Positions Maintained Single Switch Unit
Inclosure Type [AKNA]
Fully Inclosed
Unthreaded Mounting Hole Diameter [AEBV]
0.142 Inches Nominal
Switch Release Force [CRRM]
1.5 Ounces Minimum
Switch Actuating Force [CSJN]
6.0 Ounces Maximum
Switch Actuator Quantity [AFCG]
1