5930-00-583-1639
Thermostatic Switch
5930005831639 005831639 17000M0D3 1A1B2 1621183 1040S
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified). View more Thermostatic Switch
January 2023
21

Marketplace 5930-00-583-1639
Request a Quotation from participating marketplace vendors
Related Documents 5930-00-583-1639 5+ Documents (More...)
RQST NE Updated Every Day 5930-00-583-1639 RQST Updated Every Day 5930-00-583-1639 RQST NE Related Documents
5930-00-583-1639 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5930/us 5930-00-583-1639
1040S in your web browser . 6240-14-476-6192Fluorescent Lamp6240144766192 144766192 706A36-841-0016645
-1040S fsg-40/fsc-4030/us 4030-00-640-9925 Guy Anchor 4030006409925006409925,MILA3777 a day Upgrade
1040S in your web browser . 6240-14-476-6192Fluorescent Lamp6240144766192 https//www.nsnlookup.com /
fsg-59/fsc-5930/us 5930-00-583-1639 Thermostatic Switch 5930005831639 005831639 Bushing5365995344864
www.nsnlookup.com /fsg-59/fsc-5998/us 5998-01-102-1318 Circuit Card Assembly 5998011021318011021318 1621183
Thermostatic Switch 5930005831639 005831639 6255Chiave Dinamometric5120152136255 152136255 1040S
Thermostatic Switch 5930005831639 005831639 5930005831639005831639005831639 https//www.nsnlookup.com
Upgrade your Account Upgrade 5930-00-481-8175Push Switch5930004818175 00481817573913-5WGH2648AF12-1040S
Restrictions 5930-00-583-1639
5930-00-583-1639 is a Thermostatic Switch that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5930-00-583-1639
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5930-00-583-1639
- Thailand (YY01)
- Effective Date:
- 1 Feb 2015
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2005
Approved Sources 5930-00-583-1639
- Part Number
- Manufacturer
- Status
- 17000M0D3
- Manufacturer
- 73168 - Kidde Technologies, Inc (Active)
- Primary Buy
- Primary Buy
- 1A1B2
- 63325 - Vulcan Electric Co (Active)
- Secondary Buy
- Secondary Buy
- 1621183
- 10001 - Navair And Navsea Managed Original (Active)
- Secondary Buy
- Secondary Buy
- 1040S
- 00906 - Bard Electronics Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5930-00-583-1639
- Characteristic
- Specifications
- FIIG
- Specifications
- A048B0
- Body Diameter [ABPM]
- 0.618 Inches Minimum And 0.625 Inches Maximum
- Body Length [ADAQ]
- 3.500 Inches Nominal
- Bulb Diameter [AEVV]
- 0.618 Inches Minimum And 0.625 Inches Maximum
- Bulb Length [AEVU]
- 3.500 Inches Nominal
- Contact Action Stimulus [CQGB]
- Increase
- Contact Adjustability [CTYC]
- Deactuation Point Not Adjustable And Actuation Point Not Adjustable
- Contact Load Current Rating [CTHF]
- 10.0 Amperes Resistive Load Single Voltage
- Contact Stimulus Rating [CTYX]
- 34.00 Actuation Point Nominal Degrees Fahrenheit And 32.00 Deactuation Point Nominal Degrees Fahrenheit
- Contact Voltage Rating In Volts [CTZB]
- 115.0 Ac At Sea Level Single Voltage
- Media For Which Designed [MEDA]
- Gas
- Mounting Method [AXGY]
- Immersion Well
- Nonpile-Up Contact Arrangement [CRLD]
- 1 Pole, Single Throw, Normally Closed, Momentary Action
- Operating Temp Rating [AWTN]
- -20.0 Deg Fahrenheit Minimum And 160.0 Deg Fahrenheit Maximum
- Overall Length [ABHP]
- 4.750 Inches Nominal
- Style Designator [STYL]
- Cylindrical
- Overall Diameter [ADAV]
- 0.618 Inches Minimum And 0.625 Inches Maximum
- Special Features [FEAT]
- Accommodates One Tamper Proof Cap 1.250 In. Lg And 0.622 In. Dia
- Temp Sensing Element Type [AKBY]
- Bulb
- Terminal Type [CSCF]
- Wire Lead
Similar Supply Items to 5930-00-583-1639


















Freight Information 5930-00-583-1639
5930-00-583-1639 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5930-00-583-1639 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5930-00-583-1639 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 723 for ocean manifesting and military sealift. 5930-00-583-1639 is not classified as a special type of cargo when transported by water. 5930-00-583-1639 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5930-00-583-1639
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- No Requirement
- Not Applicable
- PPP-B-566 or PPP-B-676, Folding or Setup Box
- --
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container