Premium Information is available for this item - Upgrade for $1 a day
5930-00-066-6965
Thermostatic Switch
5930000666965 000666965 DAW38-3
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified). View more Thermostatic Switch
November 2023
6
Marketplace 5930-00-066-6965
Request a Quotation from participating marketplace vendors
Related Documents 5930-00-066-6965 2+ Documents (More...)
Restrictions 5930-00-066-6965
5930-00-066-6965 is a Thermostatic Switch that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
End Users 5930-00-066-6965
- NASA (G900)
- Effective Date:
- 1 Apr 1991
Approved Sources 5930-00-066-6965
- Part Number
- Manufacturer
- Status
- DAW38-3
- Manufacturer
- 39709 - Mercoid Corp The (Replaced)
- Original Design
- Original Design
- DAW38-3
- 85274 - Dwyer Instruments Inc (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5930-00-066-6965
- Characteristic
- Specifications
- Bulb Diameter [AEVV]
- Specifications
- 0.812 Inches Nominal
- Bulb Length [AEVU]
- 2.875 Inches Nominal
- Contact Action Stimulus [CQGB]
- Increase
- Contact Adjustability [CTYC]
- Deactuation Point Adjustable And Actuation Point Adjustable
- Contact Adjustment Type [CTYS]
- External Deactuation Point Knob And External Actuation Point Knob
- Contact Adjustment Range [CTYM]
- +100.00/+200.00 Actuation Point Degrees Fahrenheit And +100.00 To 200.00 Deactuation Point Degrees Fahrenheit
- Contact Load Current Rating [CTHF]
- 10.0 Amperes Resistive Load Fourth Voltage
- Contact Load Current Rating [CTHF]
- 10.0 Amperes Resistive Load Third Voltage
- Contact Load Current Rating [CTHF]
- 3.0 Amperes Resistive Load First Voltage
- Contact Load Current Rating [CTHF]
- 3.0 Amperes Resistive Load Second Voltage
- Contact Voltage Rating In Volts [CTZB]
- 115.0 Dc At Sea Level Fourth Voltage
- Contact Voltage Rating In Volts [CTZB]
- 115.0 Ac At Sea Level Third Voltage
- Contact Voltage Rating In Volts [CTZB]
- 440.0 Ac At Sea Level First Voltage
- Contact Voltage Rating In Volts [CTZB]
- 440.0 Dc At Sea Level Second Voltage
- Mounting Method [AXGY]
- Flange
- Overall Length [ABHP]
- 2.812 Inches Nominal
- Reference Number Differentiating Characteristics [ZZZY]
- As Differentiated By Contact Actuation Pointadjustment Range And Bulb Length
- Overall Diameter [ADAV]
- 7.000 Inches Nominal
- Temp Sensing Element Type [AKBY]
- Capillary Tube-Bulb
- Terminal Type [CSCF]
- Tab W/Screw
NATO Stock Numbers Related to 5930-00-066-6965
Freight Information 5930-00-066-6965
5930-00-066-6965 has freight characteristics.. 5930-00-066-6965 has a variance between NMFC and UFC when transported by rail and the description should be consulted.