Premium Information is available for this item - Upgrade for $1 a day
5925-01-552-2630
Circuit Breaker
5925015522630 015522630 AM3R-A38-LC07T-NU-20-7
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
2
Marketplace 5925-01-552-2630
Request a Quotation from participating marketplace vendors
Related Documents 5925-01-552-2630 3+ Documents (More...)
DAC: 4 8 Jun 2007 5925-01-552-2631 https//www.nsnlookup.com /cage Eaton Corp (CAGE Code 1W134) 5925-01-552-2630
Restrictions 5925-01-552-2630
5925-01-552-2630 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-01-552-2630
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-01-552-2630
- Denmark (ZS01)
- Effective Date:
- 1 Jun 2007
Approved Sources 5925-01-552-2630
- Part Number
- Manufacturer
- Status
- AM3R-A38-LC07T-NU-20-7
- Manufacturer
- 1W134 - Eaton Corp (Active)
- Primary Buy
- Primary Buy
- AM3R-A38-LC07T-NU-20-7
- L3330 - Heinemann Electric Canada (Active)
- Secondary Buy
- Secondary Buy
Datasheet 5925-01-552-2630
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Each Pole
- Body Length [ADAQ]
- 2.500 Inches Nominal
- Body Style [AAQL]
- Multipole-Multiple Actuator Type
- Body Width [ADAT]
- 2.250 Inches Nominal
- Boss Height [AJEC]
- 0.140 Inches Nominal
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.750 Inches Nominal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 1.940 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 2.062 Inches Nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 0.750 Inches Nominal
- External Actuator Linkage Arrangement [CPRY]
- One, Two, And Three Linked
- Frequency In Hertz [FREQ]
- 50.0 All Locations Or 60.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 20.0 Amperes Ac All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 5000.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 6 Threaded Hole
- Mounting Surface To Terminal End Distance [AJWX]
- 2.860 Inches Nominal
- Nominal Thread Size [CQJX]
- 0.138 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 240.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Shock Resistant And Vibration Resistant
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 3 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Special Features [FEAT]
- Operating Temperature Minus 40.0 To Plus 85.0 Degrees C.
- Thread Series Designator [THSD]
- Unc
- Thread Quantity Per Inch [CMLP]
- 32
- Thread Tolerance Class [CTTC]
- 2B Internal
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Magnetic-Hydraulic All Locations
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 15.000 Minimum At 200 Pct All Locations And 70.000 Maximum At 200 Pct All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Terminal Type And Quantity [TTQY]
- 6 Threaded Stud
NATO Stock Numbers Related to 5925-01-552-2630
Freight Information 5925-01-552-2630
5925-01-552-2630 has freight characteristics.. 5925-01-552-2630 has a variance between NMFC and UFC when transported by rail and the description should be consulted.