Premium Information is available for this item - Upgrade for $1 a day

5925-01-319-2434

Circuit Breaker

5925013192434 013192434 JA2-K3K16 65A1288 JA2-Z476-1W JA2-Z476-1 JA2-K3K16Z84-32610A

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-01-319-2434 CIRCUIT BREAKER 5925013192434 013192434

Managed by United States
NSN Created on 3 May 1990
Data Last Changed
May 2023
NATO Update Count
11
NATO Data Quality
AAQL Style 8C for 5925-01-319-2434 1/1
NSN 5925-01-319-2434 (Identification) 1/1

5925-01-319-2434 Stock and Availability Marketplace 5925-01-319-2434

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5925-01-319-2434 RQST NE eBay
eBay Updated Every Day
5925-01-319-2434 RQST eBay
Amazon Updated Every Day
5925-01-319-2434 RQST NE Amazon

5925-01-319-2434 Related Documents Related Documents 5925-01-319-2434 5+ Documents (More...)

| RNVC: 1 | DAC: 5 15 May 1970 5961-00-421-2546 https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-319-2434
Circuit Breaker 5925013192434 013192434 your Account Upgrade 5925-01-319-2434Circuit Breaker5925013192434
013192434 JA2-K3K16 65A1288 JA2-Z476 -1W JA2-Z476-1 JA2-K3K16Z84-32610A A device with means other than
Nonmetallic Bumper B-167050-2RNCC: 3 | RNVC: 2 | DAC: 5 7 Jan 1984 6635-98-857-4557 May 1990 5925-01-319-2434
4820-01-319-3448 Safety Relief Valve 31-95304-4C-150-05RNCC: 3 | RNVC: 2 | DAC: 6 5 May 1990 5925-01-319-2434
3 May 1990 5999-01-319-1750 Electrical Contact 65A1182RNCC: C | RNVC: 1 | DAC: B 3 May 1990 5925-01-319-2434
3 May 1990 5999-01-319-1750 Electrical Contact 65A1182RNCC: 3 | RNVC: 9 | DAC: B 3 May 1990 5925-01-319-2434

5925-01-319-2434 Demil Restrictions 5925-01-319-2434

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC:

5925-01-319-2434 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5925-01-319-2434 HTS and ScheduleB Import and Export 5925-01-319-2434

5925-01-319-2434 End Users End Users 5925-01-319-2434

US Navy (N9BN)
Effective Date:
1 Apr 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD
Republic of Korea (ZH01)
Effective Date:
1 Mar 2002

5925-01-319-2434 Manufacturers Approved Sources 5925-01-319-2434

5925-01-319-2434 Technical Data Datasheet 5925-01-319-2434

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Actuator Position Designation [CPRX]
At Each Pole
Arc Quenching Method [APNQ]
Magnetic Blowout
Auxiliary Trip Coil Voltage Type And Rating In Volts [CPRK]
48.0 Dc Nominal Second Location
Body Length [ADAQ]
1.968 Inches Minimum And 2.032 Inches Maximum
Body Style [AAQL]
Multipole-Multiple Actuator Type
Body Width [ADAT]
1.468 Inches Minimum And 1.532 Inches Maximum
Boss Height [AJEC]
0.098 Inches Minimum And 0.162 Inches Maximum
Case Material [ADTV]
Plastic
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
0.718 Inches Minimum And 0.782 Inches Maximum
Center To Center Distance Between Terminals Parallel To Length [AEBP]
1.528 Inches Minimum And 1.592 Inches Maximum
Circuit Protection Type [CPRH]
Overcurrent All Locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
1.628 Inches Minimum And 1.692 Inches Maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
0.718 Inches Minimum And 0.782 Inches Maximum
External Actuator Linkage Arrangement [CPRY]
One And Two Linked
Fragility Factor [AFJN]
Moderately Rugged
Frequency In Hertz [FREQ]
60.0 All Locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
1000.0 Ac All Locations
Maximum Continuous Load Current Rating Per Pole [CPLM]
40.0 Amperes Ac All Locations
Mounting Facility Type And Quantity [AXHR]
4 Threaded Hole
Mounting Surface To Terminal End Distance [AJWX]
1.898 Inches Minimum And 1.962 Inches Maximum
Nominal Thread Size [CQJX]
0.138 Inches
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
250.0 Ac All Locations
Inclosure Protection Type For Which Designed [CQXF]
Dustproof And Fungus Proof
Internal Trip Release Configuration [CPSM]
Series Trip First Location
Internal Trip Release Configuration [CPSM]
Series/Relay Trip Second Location
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
2 Toggle
Pole Quantity [AKPX]
2
Reset Method [CPRQ]
Manual
Thread Series Designator [THSD]
Unc
Trip Release Characteristic [CPRL]
Instantaneous All Locations
Trip Release Method [CPRJ]
Magnetic All Locations
Trip Release Duty Cycle [CQQC]
Continuous Second Location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
125.0 All Locations
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
6 Tab, Solder Lug
Thread Quantity Per Inch [CMLP]
32

5925-01-319-2434 Stock, Inventory and Procurement DLA Procurement Analysis 5925-01-319-2434

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-01-319-2434 Management Data Management Data 5925-01-319-2434

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5925-01-319-2434 Related Items NATO Stock Numbers Related to 5925-01-319-2434

5925-01-319-2434 Freight Data Freight Information 5925-01-319-2434

5925-01-319-2434 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-01-319-2434 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-01-319-2434 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-01-319-2434 is not classified as a special type of cargo when transported by water. 5925-01-319-2434 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-01-319-2434 Packaging Data Packaging Data 5925-01-319-2434

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
--
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-01-319-2434 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-01-319-2434 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: