Premium Information is available for this item - Upgrade for $1 a day
5925-01-298-0351
Circuit Breaker
5925012980351 012980351 8223782-01 FS340015A
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
8

Marketplace 5925-01-298-0351
Request a Quotation from participating marketplace vendors
Related Documents 5925-01-298-0351 2+ Documents (More...)
FS340015A CIRCUIT BREAKER 1 EA NS Request Quotation Updated Every Day 5925-01-298-0351 RQST NE Updated
Every Day 5925-01-298-0351 RQST Updated Every Day 5925-01-298-0351 RQST NE Related Documents 5925-01
Circuit Breaker 5925012980351 012980351 5925-01-298-0351 RQST NE Related Documents 5925-01 https
Restrictions 5925-01-298-0351
5925-01-298-0351 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-01-298-0351
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-01-298-0351
- Portugal (ZP01)
- Effective Date:
- 1 Aug 1997
Approved Sources 5925-01-298-0351
- Part Number
- Manufacturer
- Status
- 8223782-01
- Manufacturer
- 98750 - San Antonio Air Logistics Center (Replaced)
- Original Design
- Original Design
- FS340015A
- 81640 - Safran Power Usa, Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-01-298-0351
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole Two
- Body Height [ADAU]
- 3.500 Inches Nominal
- Body Length [ADAQ]
- 6.120 Inches Nominal
- Body Style [AAQL]
- Multipole-Single Actuator Type
- Body Width [ADAT]
- 4.125 Inches Nominal
- Boss Height [AJEC]
- 0.080 Inches Nominal
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.688 Inches Nominal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 4.500 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 0.750 Inches Nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 1.375 Inches Nominal
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 60.0 All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 14000.0 Ac All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 15.0 Amperes Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 6 Threaded Hole And 4 Unthreaded Hole
- Nominal Thread Size [CQJX]
- 0.250 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 440.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- General Purpose
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Thread Series Designator [THSD]
- Unf
- Trip Release Characteristic [CPRL]
- Instantaneous All Locations
- Trip Release Method [CPRJ]
- Thermal-Magnetic All Locations
- Trip Release Ambient Temp Rating [CRCF]
- 40.0 Deg Celsius Nominal All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.187 Inches Nominal
- Special Handling Feature [BBRJ]
- Magnetic
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 6 Wire Lead
- Thread Quantity Per Inch [CMLP]
- 32
DLA Procurement Analysis 5925-01-298-0351
Management Data 5925-01-298-0351
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Feb 2011
- Defense Logistics Agency (DS)
- EA
- Subscribe
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Defense Logistics Agency (DS)
- I
- Z
- Discontinued-Use 5925-01-311-3085
- Z
Similar Supply Items to 5925-01-298-0351


















Freight Information 5925-01-298-0351
5925-01-298-0351 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-01-298-0351 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-01-298-0351 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-01-298-0351 is not classified as a special type of cargo when transported by water. 5925-01-298-0351 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5925-01-298-0351
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5925-01-298-0351 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: