Premium Information is available for this item - Upgrade for $1 a day
5925-01-297-0801
Circuit Breaker
5925012970801 012970801 MIL-PRF-55629/3 M55629/3-DDIB MIL-C-55629/3
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
May 2023
4

Marketplace 5925-01-297-0801
Request a Quotation from participating marketplace vendors
Related Documents 5925-01-297-0801 5+ Documents (More...)
BUY NE FedMall Updated Every Day 5925-01-297-0801 RQST NE Updated Every Day 5925-01-297-0801 RQST
Updated Every Day 5925-01-297-0801 RQST NE Related Documents 5925-01-297-0801 5+ Documents ( More...
M55629/3-039 MIL-C-55629/3 A device with means other than fuses for automatically opening the
A device with means other than fuses for automatically opening the MIL-PRF-55629/3 CIRCUIT BREAKER
M55629/3-387 MIL-C-55629/3 A device with means other than fuses for automatically opening the
AM2A8A15-20 M55629/3-379 MIL-C-55629/3 A device with means other than fuses for automatically
M55629/3-387 MIL-C-55629/3 A device with means other than fuses for automatically opening the
AM2A8A15-20 M55629/3-379 MIL-C-55629/3 A device with means other than fuses for automatically
MIL-PRF-55629/3 CIRCUIT BREAKER 42 EA NS Request Quotation Updated Every Day 5925-01-286-9651 RQST NE
M55629/3-445 MIL-C-55629/3 A device with means other than fuses for automatically opening the
Restrictions 5925-01-297-0801
5925-01-297-0801 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-01-297-0801
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-01-297-0801
- National Security Agency (DGX1)
- Effective Date:
- 1 Apr 2006
- Former MOE Rule:
- DTX1
- Supplementary Receivers:
- TX
Approved Sources 5925-01-297-0801
- Part Number
- Manufacturer
- Status
- M55629/3-DDIB
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-PRF-55629/3
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- MIL-C-55629/3
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-01-297-0801
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Each Pole
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Length [ADAQ]
- 2.510 Inches Maximum
- Body Style [AAQL]
- Multipole-Multiple Actuator Type
- Body Width [ADAT]
- 1.469 Inches Minimum And 1.531 Inches Maximum
- Boss Height [AJEC]
- 0.109 Inches Minimum And 0.171 Inches Maximum
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.719 Inches Minimum And 0.781 Inches Maximum
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 1.660 Inches Minimum And 1.960 Inches Maximum
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 2.046 Inches Minimum And 2.078 Inches Maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 0.719 Inches Minimum And 0.781 Inches Maximum
- External Actuator Linkage Arrangement [CPRY]
- One And Two Linked
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 60.0 All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 1000.0 Ac All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 3.0 Amperes Ac Second Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 750.0 Milliamperes Ac First Location
- Mounting Facility Type And Quantity [AXHR]
- 4 Threaded Hole
- Mounting Surface To Terminal End Distance [AJWX]
- 2.553 Inches Maximum
- Nominal Thread Size [CQJX]
- 0.138 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 240.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Shock Resistant And Vibration Resistant
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 2 Toggle
- Pole Quantity [AKPX]
- 2
- Reset Method [CPRQ]
- Manual
- Thread Series Designator [THSD]
- Unc
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 0.130 Minimum At 200 Pct First Location And 1.600 Maximum At 200 Pct First Location
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 0.130 Minimum At 200 Pct Second Location And 1.400 Maximum At 200 Pct Second Location
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Magnetic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Special Handling Feature [BBRJ]
- Magnetic
- Specification/Standard Data [ZZZK]
- 81349-Mil-C-55629/3 Government Specification
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 4 Threaded Stud
- Test Data Document [TEST]
- 81349-Mil-C-55629 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
- Thread Quantity Per Inch [CMLP]
- 32
DLA Procurement Analysis 5925-01-297-0801
Management Data 5925-01-297-0801
Similar Supply Items to 5925-01-297-0801


















Freight Information 5925-01-297-0801
5925-01-297-0801 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-01-297-0801 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-01-297-0801 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-01-297-0801 is not classified as a special type of cargo when transported by water. 5925-01-297-0801 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5925-01-297-0801
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5925-01-297-0801 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: