Premium Information is available for this item - Upgrade for $1 a day
5925-01-180-6867
Circuit Breaker
5925011806867 011806867 205-111-1REC3-42F-4-101-AMO
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
5

Marketplace 5925-01-180-6867
Request a Quotation from participating marketplace vendors
Related Documents 5925-01-180-6867 2+ Documents (More...)
5925-01-180-6867 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-180-6867
/fsg-59/fsc-5925/us 5925-01-180-6867 /fsg-59/fsc-5925/us 5925-01-180-6867 Day 5925-01-180-6867 RQST
Circuit Breaker 5925011806867 011806867 United States (US) 4. 5925-01-180-6867 Marketplace Restrictions
Management Request a Quotation from participating marketplace vendors Request Updated Every Day 5925-01-180-6867
Restrictions 5925-01-180-6867
5925-01-180-6867 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5925-01-180-6867
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-01-180-6867
- France (ZF01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5925-01-180-6867
- Part Number
- Manufacturer
- Status
- 205-111-1REC3-42F-4-101-AMO
- Manufacturer
- 81541 - Sensata Technologies Maryland, Inc (Active)
- Primary Buy
- Primary Buy
Datasheet 5925-01-180-6867
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Each Pole
- Auxiliary Switch Function And Quantity [CPRZ]
- 1 Control
- Body Length [ADAQ]
- 2.490 Inches Nominal
- Body Style [AAQL]
- Multipole-Multiple Actuator Type
- Body Width [ADAT]
- 2.250 Inches Maximum
- Boss Height [AJEC]
- 0.150 Inches Nominal
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.750 Inches Nominal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 1.940 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 2.060 Inches Nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 0.750 Inches Nominal
- External Actuator Linkage Arrangement [CPRY]
- One, Two, And Three Linked
- Features Provided [CBBL]
- High Inrush Protection
- Frequency In Hertz [FREQ]
- 400.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 100.0 Milliamperes Ac All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 1000.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 6 Threaded Hole
- Mounting Surface To Terminal End Distance [AJWX]
- 2.755 Inches Nominal
- Nominal Thread Size [CQJX]
- 3.0 Millimeters
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 250.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Dustproof
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Nontrip Free
- Manual Actuator Type And Quantity [CPRT]
- 3 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 5.000 Minimum At 150 Pct All Locations And 60.000 Maximum At 150 Pct All Locations
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Duty Cycle [CQQC]
- Continuous All Locations
- Trip Release Method [CPRJ]
- Magnetic-Hydraulic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 150.0 All Locations
- Ultimate Trip Time Per Pole In Seconds [CPRP]
- 5.000 Minimum All Locations And 60.000 Maximum All Locations
- Switch Contact Arrangement [AEGJ]
- Single Pole, Double Throw
- Switch Current Rating And Type In Amps [CSSX]
- 10.0 Ac
- Switch Location And Position Designation [CQSM]
- Internal At Pole One
- Switch Terminal Type [CRTK]
- Tab, Solder Lug
- Switch Voltage Rating And Type In Volts [CSWP]
- 250.0 Ac
- Terminal Type And Quantity [TTQY]
- 6 Threaded Stud
- Test Data Document [TEST]
- 81541-2002 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
- Thread Series Designator [THSD]
- Iso S
- Thread Pitch In Millimeters [CQQR]
- 0.50
NATO Stock Numbers Related to 5925-01-180-6867
Freight Information 5925-01-180-6867
5925-01-180-6867 has freight characteristics managed by France.. 5925-01-180-6867 has a variance between NMFC and UFC when transported by rail and the description should be consulted.