Premium Information is available for this item - Upgrade for $1 a day

5925-01-124-9624

Circuit Breaker

5925011249624 011249624 372D522G02-374D212G0 AQBA1601-1200XT1

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-01-124-9624 CIRCUIT BREAKER 5925011249624 011249624

Managed by United States
NSN Created on 17 Jan 1982
Data Last Changed
January 2023
NATO Update Count
15
NATO Data Quality
AAQL Style 18B for 5925-01-124-9624 1/1
NSN 5925-01-124-9624 (Identification) 1/1

5925-01-124-9624 Stock and Availability Marketplace 5925-01-124-9624

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5925-01-124-9624 RQST NE eBay
eBay Updated Every Day
5925-01-124-9624 RQST eBay
Amazon Updated Every Day
5925-01-124-9624 RQST NE Amazon

5925-01-124-9624 Related Documents Related Documents 5925-01-124-9624 4+ Documents (More...)

372D522G02-374D212G0 AQBA1601-1200XT1 A device with means other than fuses for automatically opening
5925-01-124-9624 4+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-124-9624
Every Day 5925-01-124-9624 RQST NE Related Documents 5925-01-124-9624 4+ Documents https//www.nsnlookup.com
Documents 5925-01-122-0293 2+ Documents ( More https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-124-9624
Circuit Breaker 5925011249624 011249624 www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-124-9624
AssyUOMTechnical DocumentQuantative ExpressionDefense Logistics Agency (DS)IZDiscontinued-Use 5925-01-124-9624
Upgrade your Account Upgrade 5925-00-102-6086Circuit Breaker Tripper5925001026086 001026086 372D522G02-374D212G0
6086 RQST NE Restrictions https//www.nsnlookup.com https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-124-9624
Circuit Breaker 5925011249624 011249624 a day Upgrade your Account Upgrade 5925-01-124-9624Circuit
4401 RQST NE Related Documents 5925-01-105-4401 https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-124-9624
Circuit Breaker 5925011249624 011249624 for $1 a day Upgrade your Account Upgrade 5925-01-124-9624Circuit
Breaker5925011249624 011249624 372D522G02 //www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01-124-9624 Circuit

5925-01-124-9624 Demil Restrictions 5925-01-124-9624

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

5925-01-124-9624 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5925-01-124-9624 HTS and ScheduleB Import and Export 5925-01-124-9624

5925-01-124-9624 End Users End Users 5925-01-124-9624

Malaysia (YW01)
Effective Date:
1 Sep 2008

5925-01-124-9624 Manufacturers Approved Sources 5925-01-124-9624

5925-01-124-9624 Technical Data Datasheet 5925-01-124-9624

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Adjustable Trip Setting Current Range Per Pole In Amps [CPSF]
+2000.0/+6000.0 Ac All Locations
Actuator Position Designation [CPRX]
At Pole Two
Body Height [ADAU]
12.243 Inches Nominal
Body Length [ADAQ]
22.000 Inches Nominal
Body Style [AAQL]
Multipole-Single Actuator Type
Body Width [ADAT]
12.000 Inches Nominal
Boss Height [AJEC]
0.813 Inches Nominal
Case Material [ADTV]
Plastic
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
4.000 Inches Nominal
Center To Center Distance Between Terminals Parallel To Length [AEBP]
14.375 Inches Nominal
Circuit Protection Type [CPRH]
Overcurrent All Locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
13.625 Inches Nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
4.000 Inches Nominal
Features Provided [CBBL]
Adjustable Trip Release
Frequency In Hertz [FREQ]
60.0 All Locations
Maximum Continuous Load Current Rating Per Pole [CPLM]
1200.0 Amperes Ac All Locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
50000.0 Ac All Locations
Mounting Facility Type And Quantity [AXHR]
4 Threaded Stud
Nominal Thread Size [CQJX]
0.375 Inches
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
500.0 Ac All Locations
Inclosure Protection Type For Which Designed [CQXF]
Fungus Resistant
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
1 Toggle
Pole Quantity [AKPX]
3
Reset Method [CPRQ]
Manual
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
0.041 Minimum At 200 Pct All Locations And 0.045 Maximum At 200 Pct All Locations
Trip Release Ambient Temp Rating [CRCF]
40.0 Deg Celsius Nominal All Locations
Trip Release Characteristic [CPRL]
Instantaneous All Locations And Time Delay All Locations
Trip Release Method [CPRJ]
Thermal-Magnetic All Locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
140.0 All Locations
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
6 Quick Disconnect, Male
Thread Series Designator [THSD]
Unc
Thread Quantity Per Inch [CMLP]
16

5925-01-124-9624 Stock, Inventory and Procurement DLA Procurement Analysis 5925-01-124-9624

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-01-124-9624 Management Data Management Data 5925-01-124-9624

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2003
Defense Logistics Agency (DS)
EA
Subscribe
MOE
USC
Code
Statement
Order of Use
Jump To Code
Qty Per Assy
UOM
Technical Document
Quantative Expression
Defense Logistics Agency (DS)
I
V
Discontinued Without Replacement

5925-01-124-9624 Similar Items Similar Supply Items to 5925-01-124-9624

5925-01-124-9624 Freight Data Freight Information 5925-01-124-9624

5925-01-124-9624 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-01-124-9624 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-01-124-9624 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-01-124-9624 is not classified as a special type of cargo when transported by water. 5925-01-124-9624 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-01-124-9624 Packaging Data Packaging Data 5925-01-124-9624

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
MIL-DTL-17667, Neutral Wrapping Paper
ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
--
ASTM-D5118, Type CF, Class Domestic, Corrugated Fiberboard Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-01-124-9624 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-01-124-9624 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: