Premium Information is available for this item - Upgrade for $1 a day
5925-01-097-0333
Circuit Breaker
5925010970333 010970333 APGX6-3374-1 5925-00-LG3-1515 APGX61-51-103-81
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
4

Marketplace 5925-01-097-0333
Request a Quotation from participating marketplace vendors
Related Documents 5925-01-097-0333 1+ Documents (More...)
Day 5925-01-097-0333 RQST Updated Every Day 5925-01-097-0333 RQST NE Related Documents 5925-01-097-0333
RQST Updated Every Day 5925-01-097-0333 RQST NE Related Documents 5925-01-097-0333 RQST NE Updated
Restrictions 5925-01-097-0333
5925-01-097-0333 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-01-097-0333
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-01-097-0333
- US Coast Guard (C056)
- Effective Date:
- 1 Jun 2010
- Former MOE Rule:
- C165
Approved Sources 5925-01-097-0333
- Part Number
- Manufacturer
- Status
- APGX6-3374-1
- Manufacturer
- 81541 - Sensata Technologies Maryland, Inc (Active)
- Primary Buy
- Primary Buy
- 5925-00-LG3-1515
- 06101 - United States Coast Guard Yard (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- APGX61-51-103-81
- 81541 - Sensata Technologies Maryland, Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-01-097-0333
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- End Item Identification [AGAV]
- D.C. Electrical Panel Onboard 41 Ft Utb Coast Guard Vessels
- Body Style [AAQL]
- Rectangular Dimensional Envelope
- Case Material [ADTV]
- Plastic
- Circuit Protection Type [CPRH]
- Overcurrent Single Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 10.0 Amperes Dc Single Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 1000.0 Dc Single Location
- Mounting Facility Type And Quantity [AXHR]
- 2 Threaded Hole
- Nominal Thread Size [CQJX]
- 0.156 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 65.0 Dc Single Location
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Pole Quantity [AKPX]
- 1
- Reset Method [CPRQ]
- Manual
- Overall Height [ABKW]
- 0.750 Inches Nominal
- Overall Length [ABHP]
- 2.422 Inches Nominal
- Overall Width [ABMK]
- 2.000 Inches Nominal
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 51.500 Minimum At 125 Pct Single Location And 57.500 Maximum At 125 Pct Single Location
- Trip Release Ambient Temp Rating [CRCF]
- 40.0 Deg Celsius Nominal Single Location
- Trip Release Characteristic [CPRL]
- Time Delay Single Location
- Trip Release Method [CPRJ]
- Thermal-Magnetic Single Location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 1000.0 Single Location
- Ultimate Trip Time Per Pole In Seconds [CPRP]
- 0.004 Minimum Single Location And 0.025 Maximum Single Location
- Terminal Type And Quantity [TTQY]
- 6 Screw
- Thread Series Designator [THSD]
- Unc
NATO Stock Numbers Related to 5925-01-097-0333
Freight Information 5925-01-097-0333
5925-01-097-0333 has freight characteristics managed by the US Postal Service (USPS).. 5925-01-097-0333 has a variance between NMFC and UFC when transported by rail and the description should be consulted.