Premium Information is available for this item - Upgrade for $1 a day
5925-01-080-2225
Circuit Breaker
5925010802225 010802225 VTS 898752-2 AM3Z239-2
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
10

Marketplace 5925-01-080-2225
Request a Quotation from participating marketplace vendors
Related Documents 5925-01-080-2225 5+ Documents (More...)
VTS CIRCUIT BREAKER 15 EA NS Request Quotation Updated Every Day 5925-01-080-2225 RQST NE Updated Every
opening the circuit in VTS CIRCUIT BREAKER 15 EA NS Request Quotation Updated Every Day 5925-01-080-
Circuit Breaker 5925010802225 010802225,VTS $1 a day Upgrade your Account Upgrade 5925-01-080-2225Circuit
Breaker5925010802225 010802225 VTS 898752 - Sensata Technologies Maryland, Inc (Active) Incomplete Secondary
0781-3513 VTS-250D-580 An item designed to deliver https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-
01-080-2225 Circuit Breaker 5925010802225 010802225,VTS ,VTS -250B-580-0781-3508/80 VTS-250B-0781-3508
Circuit Breaker 5925010802225 010802225,VTS ,VTS -250B-580-0781-3508/80 VTS-250B-0781-3508 An item -0781
-3513 VTS-250D-580 An https//www.nsnlookup.com -0781-3513 VTS-250D- / -250B -580-0781-3508 VTS -250D-
VTS 621-VTS SPA-M-30364 https//www.nsnlookup.com https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-01
-080-2225 Circuit Breaker 5925010802225 010802225,VTS Power Transformer 5950010458725010458725 https/
Restrictions 5925-01-080-2225
5925-01-080-2225 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5925-01-080-2225
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-01-080-2225
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5925-01-080-2225
- Part Number
- Manufacturer
- Status
- 898752-2
- Manufacturer
- 3B150 - Raytheon Company (Active)
- Primary Buy
- Primary Buy
- VTS
- 81541 - Sensata Technologies Maryland, Inc (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 898752-2
- 49956 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- AM3Z239-2
- 74193 - Eaton Corp Heinemann Products (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-01-080-2225
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Each Pole
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Length [ADAQ]
- 2.490 Inches Minimum And 2.510 Inches Maximum
- Body Style [AAQL]
- Multipole-Multiple Actuator Type
- Body Width [ADAT]
- 2.220 Inches Minimum And 2.280 Inches Maximum
- Boss Height [AJEC]
- 0.130 Inches Minimum And 0.150 Inches Maximum
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.740 Inches Minimum And 0.760 Inches Maximum
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 1.928 Inches Minimum And 1.948 Inches Maximum
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 2.052 Inches Minimum And 2.072 Inches Maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 0.130 Inches Minimum And 0.150 Inches Maximum
- External Actuator Linkage Arrangement [CPRY]
- One, Two, And Three Linked
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 60.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 3.0 Amperes Ac All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 1000.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 6 Threaded Hole
- Mounting Surface To Terminal End Distance [AJWX]
- 2.461 Inches Minimum And 2.481 Inches Maximum
- Nominal Thread Size [CQJX]
- 0.138 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 240.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Dustproof
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 3 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Magnetic-Hydraulic All Locations
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 2.000 Minimum At 200 Pct All Locations And 20.000 Maximum At 200 Pct All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 6 Threaded Stud
- Thread Series Designator [THSD]
- Unc
- Thread Quantity Per Inch [CMLP]
- 32
Similar Supply Items to 5925-01-080-2225


















Freight Information 5925-01-080-2225
5925-01-080-2225 has freight characteristics managed by the Netherlands.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-01-080-2225 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. 5925-01-080-2225 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-01-080-2225 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-01-080-2225 is not classified as a special type of cargo when transported by water. 5925-01-080-2225 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.