Premium Information is available for this item - Upgrade for $1 a day

5925-00-595-9394

Circuit Breaker

5925005959394 005959394 MIL-PRF-55629/3 APL-11-55629/3-115 16B112 M55629-3-115 W92X11-2-30 AM33MG6-30-250-4 M55629/3-115 AM33MG6-30-250-4-60 GC885AL30 AM33-30-250VAC60C4 AM33MG6-30-250-60CYC4 190-230-101 037-225 MIL-C-55629/3

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-00-595-9394 CIRCUIT BREAKER 5925005959394 005959394

Managed by United States
NSN Created on 10 Jan 1975
Data Last Changed
November 2023
NATO Update Count
51
NATO Data Quality
AAQL Style 8C for 5925-00-595-9394 1/1
NSN 5925-00-595-9394 (Identification) 1/1

5925-00-595-9394 Stock and Availability Marketplace 5925-00-595-9394

5925-00-595-9394 Related Documents Related Documents 5925-00-595-9394 5+ Documents (More...)

MIL-PRF-55629/3 APL-11-55629/3-115 16B112 M55629-3-115 W92X11-2-30 AM33MG6-30-250-4 M55629/3-115 AM33MG6
-30-250-4-60 GC885AL30 AM33-30-250VAC60C4 AM33MG6-30-250-60CYC4 190-230-101 037-225 MIL-C-55629/3 A device
Every Day 5925-00-595-9394 RQST Updated Every Day 5925-00-595-9394 RQST NE Related Documents 5925-00
for $1 a day Upgrade your Account Upgrade 5925-00-933-6041Circuit Breaker5925009336041 009336041 037-225
AM33MG6-30-250-4-60 AM33MG6-30-250-60CYC4 GC885AL30 AM33-30-250VAC60C4 190-230-101 A device with
Circuit Breaker 5925005959394 005959394 GC885AL30AM33-30-250VAC60C4AM33MG6-30-250-60CYC4190-230
009336041 a day Upgrade your Account Upgrade 5925-00-933-6041Circuit Breaker5925009336041 009336041 037-225
AM33MG6 -30-250-4-60 AM33MG6-30-250-60CYC4 GC885AL30 AM33-30-250VAC60C4 190-230-101 A device with
M55629/3-097 MIL-C-55629/3 A device with means other than fuses for automatically opening the
M55629/3-387 MIL-C-55629/3 A device with means other than fuses for automatically opening the
AM2A8A15-20 M55629/3-379 MIL-C-55629/3 A device with means other than fuses for automatically
M55629/3-016 MIL-C-55629/3 A device with means other than fuses for automatically opening the
M55629/3-387 MIL-C-55629/3 A device with means other than fuses for automatically opening the
AM2A8A15-20 M55629/3-379 MIL-C-55629/3 A device with means other than fuses for automatically

5925-00-595-9394 Demil Restrictions 5925-00-595-9394

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

5925-00-595-9394 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5925-00-595-9394 HTS and ScheduleB Import and Export 5925-00-595-9394

5925-00-595-9394 End Users End Users 5925-00-595-9394

US Army (A918)
Effective Date:
1 Apr 2006
Former MOE Rule:
A196
Supplementary Receivers:
BFBS
US Air Force (FXGX)
Effective Date:
1 Apr 2006
Former MOE Rule:
FXTX
NASA (G860)
Effective Date:
1 Apr 1991
US Marine Corps (MC49)
Effective Date:
1 Apr 2006
Former MOE Rule:
MC13
US Navy (N9BN)
Effective Date:
1 Apr 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
GTKEJVHSHD
Spain (YB01)
Effective Date:
1 May 1997
Australia (ZA01)
Effective Date:
1 Apr 1991
France (ZF01)
Effective Date:
1 May 2015
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Philippines (ZM01)
Effective Date:
1 Feb 2015
Portugal (ZP01)
Effective Date:
1 Apr 1991

5925-00-595-9394 Manufacturers Approved Sources 5925-00-595-9394

5925-00-595-9394 Technical Data Datasheet 5925-00-595-9394

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Actuator Position Designation [CPRX]
At Each Pole
Arc Quenching Method [APNQ]
Magnetic Blowout
Body Length [ADAQ]
2.510 Inches Maximum
Body Style [AAQL]
Multipole-Multiple Actuator Type
Body Width [ADAT]
1.500 Inches Nominal
Boss Height [AJEC]
0.140 Inches Nominal
Case Material [ADTV]
Plastic
Center To Center Distance Between Terminals Parallel To Length [AEBP]
1.660 Inches Minimum And 1.960 Inches Maximum
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
0.750 Inches Nominal
Circuit Protection Type [CPRH]
Overcurrent All Locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
2.046 Inches Minimum And 2.078 Inches Maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
0.750 Inches Nominal
External Actuator Linkage Arrangement [CPRY]
One And Two Linked
Fragility Factor [AFJN]
Moderately Rugged
Frequency In Hertz [FREQ]
60.0 All Locations
Maximum Continuous Load Current Rating Per Pole [CPLM]
30.0 Amperes Ac All Locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
1000.0 Ac All Locations
Mounting Facility Type And Quantity [AXHR]
4 Threaded Hole
Mounting Surface To Terminal End Distance [AJWX]
2.553 Inches Maximum
Nominal Thread Size [CQJX]
0.138 Inches
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
240.0 Ac All Locations
Inclosure Protection Type For Which Designed [CQXF]
Fungus Resistant And Moisture Resistant And Salt Spray Proof And Shock Resistant And Vibration Resistant
Internal Trip Release Configuration [CPSM]
Series Trip All Locations
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
2 Toggle
Pole Quantity [AKPX]
2
Reset Method [CPRQ]
Manual
Special Handling Feature [BBRJ]
Magnetic
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
2.200 Minimum At 200 Pct All Locations And 20.000 Maximum At 200 Pct All Locations
Trip Release Characteristic [CPRL]
Time Delay All Locations
Trip Release Method [CPRJ]
Magnetic All Locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
125.0 All Locations
Specification/Standard Data [ZZZK]
81349-Mil-C-55629/3 Government Specification
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
4 Threaded Stud
Test Data Document [TEST]
81349-Mil-C-55629 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
Thread Pitch Diameters [AAJE]
+0.1177/+0.1214 Inches
Thread Quantity Per Inch [CMLP]
32
Thread Series Designator [THSD]
Unc

5925-00-595-9394 Weapon Systems (WSDC) Weapon Systems (WSDC) 5925-00-595-9394

5925-00-595-9394 Stock, Inventory and Procurement DLA Procurement Analysis 5925-00-595-9394

Last Stock Position:
27 In Stock
DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-00-595-9394 Management Data Management Data 5925-00-595-9394

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Jan 2023
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2022
US Marine Corps (DM)
EA
Subscribe
1
Oct 2021
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2020
Defense Logistics Agency (DS)
EA
Subscribe
1
Feb 2020
Department of the Air Force (DF)
EA
Subscribe
1
MOE
USC
Code
Statement
Order of Use
Jump To Code
Qty Per Assy
UOM
Technical Document
Quantative Expression
US Marine Corps (DM)
M
0
Reversal Of Phrase Code Z 5925-01-017-3240

Army Army

Materiel Category and Inventory Manager:
Q
Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity:
2
Stock Fund Secondary Items
Management Inventory Segment:
2
Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
Weapons System / End Item / Homogeneous Group:
00
DLA/GSA Material
DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements:
X
Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.

Air Force Air Force

Fund:
SF
Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
Budget:
9
57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
Aggregation Code:
EH
ELECTRONIC COMPONENTS
Price Validation Code:
N
The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ā€œLā€ or ā€œFā€, then it must be evaluated locally where purchased or fabricated.
Expendability
Recoverability
Repairability:
N
Expendable. Condemn at User. Stock Fund (except Munitions).

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Special Material Content:
9
Non-Hazardous or Non-Sensitive Item

Marine Corps Marine Corps

Stores Account:
1
Stock Fund Account Item
Combat Essentiality:
5
Critical Repair Part to a Combat Essential End Item
Echelon Management:
B2
Operational Test:
No Special Procedures

5925-00-595-9394 Similar Items Similar Supply Items to 5925-00-595-9394

5925-00-595-9394 Freight Data Freight Information 5925-00-595-9394

5925-00-595-9394 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-595-9394 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-595-9394 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-595-9394 is not classified as a special type of cargo when transported by water. 5925-00-595-9394 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-00-595-9394 Packaging Data Packaging Data 5925-00-595-9394

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
--
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-00-595-9394 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-00-595-9394 October 2021

Criticality and Quality

Critical Item Code:
X
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
F

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: