A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
4
Marketplace 5925-00-422-5150
Request a Quotation from participating marketplace vendors
Related Documents 5925-00-422-5150 1+ Documents (More...)
Restrictions 5925-00-422-5150
5925-00-422-5150 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-00-422-5150
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-422-5150
- NASA (G860)
- Effective Date:
- 1 Apr 1991
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2005
Approved Sources 5925-00-422-5150
- Part Number
- Manufacturer
- Status
- FB3050L
- Manufacturer
- 89946 - Eaton Corporation (Active)
- Primary Buy
- Primary Buy
Datasheet 5925-00-422-5150
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole Two
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Height [ADAU]
- 3.375 Inches Nominal
- Body Length [ADAQ]
- 6.000 Inches Nominal
- Body Style [AAQL]
- Multipole-Single Actuator Type
- Body Width [ADAT]
- 4.125 Inches Nominal
- Boss Height [AJEC]
- 0.125 Inches Nominal
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 1.375 Inches Nominal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 5.062 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 4.500 Inches Nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 1.375 Inches Nominal
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 400.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 50.0 Amperes Ac All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 20000.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 4 Unthreaded Hole
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 600.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Fungus Resistant And Moisture Resistant
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 28.000 Minimum At 200 Pct All Locations And 73.000 Maximum At 200 Pct All Locations
- Trip Release Ambient Temp Rating [CRCF]
- 40.0 Deg Celsius Nominal All Locations
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Thermal-Magnetic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.188 Inches Nominal
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 6 Compression
NATO Stock Numbers Related to 5925-00-422-5150
Freight Information 5925-00-422-5150
5925-00-422-5150 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-422-5150 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-422-5150 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-422-5150 is not classified as a special type of cargo when transported by water. 5925-00-422-5150 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.