Premium Information is available for this item - Upgrade for $1 a day
5925-00-345-6494
Circuit Breaker
5925003456494 003456494 2131850-13 AP112-1918-13
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
![]()
May 2023
5

Marketplace 5925-00-345-6494
Request a Quotation from participating marketplace vendors
Related Documents 5925-00-345-6494 3+ Documents (More...)
AP112-1918-13 CIRCUIT BREAKER 2 EA NS Request Quotation FedMall Updated Every 15 Minutes 5925-00-345-
6494 BUY NE FedMall Updated Every Day 5925-00-345-6494 RQST NE Updated Every Day 5925-00-345-6494 RQST
Circuit Breaker 5925003456494 003456494 Every Day 5925-00-345-6494 RQST NE Related Documents 5925
-00-345-6494 3+ Documents ( More... ) https BUY NE FedMall Updated Every Day 5925-00-345-6494 RQST NE
Circuit Breaker 5925003456494 003456494 www.nsnlookup.com /fsg-47/fsc-4720/us 4720-01-674-1813
Nonmetallic Hose Assembly 4720016741813 Restrictions 6110-01-345-6494 Updated Every Day 5925-00-345-6494
Restrictions 5925-00-345-6494
5925-00-345-6494 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-00-345-6494
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-345-6494
- National Security Agency (DGX1)
- Effective Date:
- 1 Jul 2005
- Former MOE Rule:
- DTX1
- Supplementary Receivers:
- TX
Approved Sources 5925-00-345-6494
- Part Number
- Manufacturer
- Status
- 2131850-13
- Manufacturer
- 55974 - Honeywell Intl Inc (Active)
- Primary Buy
- Primary Buy
- AP112-1918-13
- 81541 - Sensata Technologies Maryland, Inc (Active)
- Secondary Buy
- Secondary Buy
- 2131850-13
- 19315 - Honeywell Intl Inc Defense Avionics (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-00-345-6494
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole Two
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Length [ADAQ]
- 1.500 Inches Maximum
- Body Style [AAQL]
- Multipole-Single Actuator Type
- Body Width [ADAT]
- 1.875 Inches Maximum
- Bushing Length [ABXD]
- 0.380 Inches Maximum
- Case Material [ADTV]
- Metal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 0.870 Inches Minimum And 0.880 Inches Maximum
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.620 Inches Minimum And 0.630 Inches Maximum
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 60.0 First Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 1.0 Amperes Ac First Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 10.0 Amperes Dc Second Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 2.0 Amperes Dc Third Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 300.0 Ac First Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 500.0 Dc Second Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 500.0 Dc Third Location
- Mounting Facility Type And Quantity [AXHR]
- 1 Threaded Bushing W/Panel Seal
- Mounting Surface To Terminal End Distance [AJWX]
- 1.780 Inches Maximum
- Nominal Thread Size [CQJX]
- 0.375 Inches
- Nonturn Device Radius [AEFP]
- 0.620 Inches Minimum And 0.630 Inches Maximum
- Nonturn Device Diameter [AEFS]
- 0.245 Inches Minimum And 0.255 Inches Maximum
- Nonturn Device Length [AEFQ]
- 0.135 Inches Minimum And 0.145 Inches Maximum
- Nonturn Device Location [AEFN]
- At 3 Oclock And At 9 Oclock
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 115.0 Ac First Location
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 50.0 Dc Second Location
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 50.0 Dc Third Location
- Inclosure Protection Type For Which Designed [CQXF]
- Hermetically Sealed
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 0.055 Minimum At 200 Pct All Locations And 0.950 Maximum At 200 Pct All Locations
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Magnetic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 115.0 All Locations
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 6 Wire Hook
- Thread Quantity Per Inch [CMLP]
- 32
- Thread Pitch Diameters [AAJE]
- +0.3547/+0.3591 Inches
- Thread Series Designator [THSD]
- Unef
DLA Procurement Analysis 5925-00-345-6494
Management Data 5925-00-345-6494
Similar Supply Items to 5925-00-345-6494


















Freight Information 5925-00-345-6494
5925-00-345-6494 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-345-6494 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-345-6494 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-345-6494 is not classified as a special type of cargo when transported by water. 5925-00-345-6494 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5925-00-345-6494
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5925-00-345-6494 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: