5925-00-245-3391

Circuit Breaker

5925002453391 002453391 127-0156 APL53-155-2

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-00-245-3391 CIRCUIT BREAKER 5925002453391 002453391

Managed by United States
NSN Created on 1 Jul 1969
Data Last Changed
May 2023
NATO Update Count
3
NATO Data Quality
AAQL Style 8C for 5925-00-245-3391 1/1
NSN 5925-00-245-3391 (Identification) 1/1

5925-00-245-3391 Stock and Availability Marketplace 5925-00-245-3391

Need Help?
Request a Quotation from participating marketplace vendors
FedMallFedMall.mil Updated Every 15 Minutes
5925-00-245-3391 BUY NE FedMallFedMall.mil
eBay Updated Every Day
5925-00-245-3391 RQST NE eBay
eBay Updated Every Day
5925-00-245-3391 RQST eBay
Amazon Updated Every Day
5925-00-245-3391 RQST NE Amazon

5925-00-245-3391 Related Documents Related Documents 5925-00-245-3391 5+ Documents (More...)

5975-99-997-8243 5975-27-058-6716 5975-99-004-5015 https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-00-245-3391
Circuit Breaker 5925002453391 002453391 2920121270156 121270156 Restrictions 5945-12-134-7706 DEMIL
United States (US) 4. 5970-01-127-0156 Marketplace Restrictions Approved Sources Datasheet Management
Request a Quotation from participating marketplace vendors Request Updated Every Day 5970-01-127-0156
RQST NE Updated Every Day 5970-01-127-0156 RQST Updated Every Day 5970-01-127-0156 RQST NE Restrictions
RNVC: 2 | DAC: 3 30 May 1969 5945-12-134-7706 https//www.nsnlookup.com /fsg-29/fsc-2920/de 2920-12-127-0156
2920121270156 121270156 2920-12-127-0156 2920121270156 121270156 Restrictions 5945-12-134-7706 DEMIL
142450156 2920-14-245-0156 2920142450156 142450156 https//www.nsnlookup.com /fsg-29/fsc-2920/de 2920-12-127-0156
2920121270156 121270156 2920-12-127-0156 2920121270156 121270156 https//www.nsnlookup.com /fsg-84/fsc

5925-00-245-3391 Demil Restrictions 5925-00-245-3391

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC:

5925-00-245-3391 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5925-00-245-3391 HTS and ScheduleB Import and Export 5925-00-245-3391

5925-00-245-3391 End Users End Users 5925-00-245-3391

US Navy (N9BN)
Effective Date:
1 Apr 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
KE

5925-00-245-3391 Manufacturers Approved Sources 5925-00-245-3391

5925-00-245-3391 Technical Data Datasheet 5925-00-245-3391

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Actuator Position Designation [CPRX]
At Each Pole
Arc Quenching Method [APNQ]
Air
Body Length [ADAQ]
2.530 Inches Nominal
Body Style [AAQL]
Multipole-Multiple Actuator Type
Body Width [ADAT]
1.530 Inches Nominal
Boss Height [AJEC]
0.150 Inches Nominal
Case Material [ADTV]
Plastic
Center To Center Distance Between Terminals Parallel To Length [AEBP]
1.940 Inches Nominal
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
0.750 Inches Nominal
Circuit Protection Type [CPRH]
Overcurrent All Locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
2.060 Inches Nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
0.750 Inches Nominal
External Actuator Linkage Arrangement [CPRY]
One And Two Linked
Fragility Factor [AFJN]
Moderately Rugged
Frequency In Hertz [FREQ]
60.0 Second Location
Maximum Continuous Load Current Rating Per Pole [CPLM]
18.0 Amperes Ac Second Location
Maximum Continuous Load Current Rating Per Pole [CPLM]
200.0 Milliamperes Dc First Location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
3000.0 Ac Second Location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
3000.0 Dc First Location
Mounting Facility Type And Quantity [AXHR]
4 Threaded Hole
Mounting Surface To Terminal End Distance [AJWX]
2.630 Inches Nominal
Nominal Thread Size [CQJX]
0.190 Inches
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
250.0 Ac Second Location
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
250.0 Dc First Location
Inclosure Protection Type For Which Designed [CQXF]
Fungus Resistant And Moisture Resistant
Internal Trip Release Configuration [CPSM]
Relay Trip First Location
Internal Trip Release Configuration [CPSM]
Shunt Trip Second Location
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
2 Toggle
Pole Quantity [AKPX]
2
Reset Method [CPRQ]
Manual
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
4.000 Minimum At 200 Pct Second Location And 10.000 Maximum At 200 Pct Second Location
Trip Release Characteristic [CPRL]
Instantaneous First Location
Trip Release Characteristic [CPRL]
Time Delay Second Location
Trip Release Method [CPRJ]
Magnetic-Hydraulic All Locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
115.0 All Locations
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
7 Threaded Stud
Thread Quantity Per Inch [CMLP]
32
Thread Series Designator [THSD]
Unc

5925-00-245-3391 Stock, Inventory and Procurement DLA Procurement Analysis 5925-00-245-3391

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-00-245-3391 Management Data Management Data 5925-00-245-3391

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5925-00-245-3391 Related Items NATO Stock Numbers Related to 5925-00-245-3391

5925-00-245-3391 Freight Data Freight Information 5925-00-245-3391

5925-00-245-3391 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-245-3391 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-245-3391 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-245-3391 is not classified as a special type of cargo when transported by water. 5925-00-245-3391 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-00-245-3391 Packaging Data Packaging Data 5925-00-245-3391

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
--
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-00-245-3391 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-00-245-3391 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: