Premium Information is available for this item - Upgrade for $1 a day
5925-00-238-5145
Circuit Breaker
5925002385145 002385145 VA2A6A3 127-0286 UPGH-14-1980-1 JA2-Z79-1
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
![]()
May 2023
5

Marketplace 5925-00-238-5145
Request a Quotation from participating marketplace vendors
Related Documents 5925-00-238-5145 5+ Documents (More...)
BUY NE FedMall Updated Every Day 5925-00-238-5145 RQST NE Updated Every Day 5925-00-238-5145 RQST
Updated Every Day 5925-00-238-5145 RQST NE Related Documents 5925-00-238-5145 5+ Documents ( More...
-98557126-9AM3-Z79-1 Circuit Card Assembly 5998009636780009636780 127-0286 Restrictions 8405-99-127-0286
https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-00-238-5145 Circuit Breaker 5925002385145 002385145
/fsg-65/fsc-6505/dk 6505-22-127-0286 /fsg-65/fsc-6505/dk 6505-22-127-0286 /fsg-65/fsc-6505/dk 6505-22
-127-0286 /fsg-65/fsc-6505/dk 6505-22 https//www.nsnlookup.com /fsg-59/fsc-5925/us 5925-00-238-5145 Circuit
5330-00-127-0286 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-53/fsc-5330/us 5330-00-127-0286
RQST NE Updated Every Day 5330-00-127-0286 RQST Updated Every Day 5330-00-127-0286 RQST NE Restrictions
5330-01-127-0286 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-53/fsc-5330/us 5330-01-127-0286
Circuit Breaker 5925002385145 002385145 Every Day 5330-00-127-0286 RQST NE Restrictions https//
Restrictions 5925-00-238-5145
5925-00-238-5145 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-00-238-5145
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-238-5145
- US Air Force (FXGX)
- Effective Date:
- 1 Apr 2006
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Apr 2006
- Supplementary Collaborators:
- GTKE
Approved Sources 5925-00-238-5145
- Part Number
- Manufacturer
- Status
- 127-0286
- Manufacturer
- 85604 - Kepco, Inc. (Active)
- Primary Buy
- Primary Buy
- UPGH-14-1980-1
- 81541 - Sensata Technologies Maryland, Inc (Active)
- Secondary Buy
- Secondary Buy
- JA2-Z79-1
- 74193 - Eaton Corp Heinemann Products (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- VA2A6A3
- 84784 - Lear Siegler Inc Heinemann Saw Div (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5925-00-238-5145
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Each Pole
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Length [ADAQ]
- 1.985 Inches Minimum And 2.015 Inches Maximum
- Body Style [AAQL]
- Multipole-Multiple Actuator Type
- Body Width [ADAT]
- 1.468 Inches Minimum And 1.532 Inches Maximum
- Boss Height [AJEC]
- 0.125 Inches Minimum And 0.135 Inches Maximum
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 1.555 Inches Minimum And 1.565 Inches Maximum
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.745 Inches Minimum And 0.755 Inches Maximum
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 1.655 Inches Minimum And 1.665 Inches Maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 0.745 Inches Minimum And 0.755 Inches Maximum
- External Actuator Linkage Arrangement [CPRY]
- One And Two Linked
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 60.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 8.0 Amperes Ac Second Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 1.0 Amperes Ac First Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 1000.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 4 Threaded Hole
- Mounting Surface To Terminal End Distance [AJWX]
- 1.835 Inches Minimum And 1.845 Inches Maximum
- Nominal Thread Size [CQJX]
- 0.138 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 250.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Dustproof
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 2 Toggle
- Pole Quantity [AKPX]
- 2
- Reset Method [CPRQ]
- Manual
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 0.150 Minimum At 200 Pct All Locations And 0.300 Maximum At 200 Pct All Locations
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Magnetic-Hydraulic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 4 Tab, Solder Lug
- Thread Quantity Per Inch [CMLP]
- 32
- Thread Series Designator [THSD]
- Unc
DLA Procurement Analysis 5925-00-238-5145
Management Data 5925-00-238-5145
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Apr 2023
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Oct 2022
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Oct 2021
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Oct 2020
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5925-00-238-5145


















Freight Information 5925-00-238-5145
5925-00-238-5145 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-238-5145 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-238-5145 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-238-5145 is not classified as a special type of cargo when transported by water. 5925-00-238-5145 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5925-00-238-5145
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5925-00-238-5145 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: