Premium Information is available for this item - Upgrade for $1 a day
5925-00-173-7646
Circuit Breaker
5925001737646 001737646 F3100 1531789 1531-789 1A4161-20SUB33 371D376G20 1222019 1222019-250 AB100 AB100A
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
November 2023
37

Marketplace 5925-00-173-7646
Request a Quotation from participating marketplace vendors
Related Documents 5925-00-173-7646 5+ Documents (More...)
AB100 CIRCUIT BREAKER 2 EA NS Request Quotation Updated Every Day 5925-00-173-7646 RQST NE Updated Every
A device with means AB100 CIRCUIT BREAKER 2 EA NS Request Quotation Updated Every Day 5925-00-173-7646
NE Updated Every Day -66 /fsc-6685/ es 6685-33-156 331563468 -21200-F3100 NE 6685331563468 -21200 -F3100
NE Updated https//www.nsnlookup.com Thermostat6685331563468 331563468 -21200-F3100 NE Updated Every
-4S1 AB100-2S1 An item designed to inclose the cylinder bore(s) of an engine block to form a combustion
www.nsnlookup.com /fsg-28/fsc-2805/us 2805-00-653-5683 Gasoline Engine Cylinder Head 2805006535683 AB100
AB100A CYLINDER HEAD,GASOLINE ENGINE 1 EA NS Request Quotation Subscribe to View Vendor Details...
Circuit Breaker 5925001737646 001737646,F3100 Gasoline Engine Cylinder Head 2805004229060 Account
AB100 CIRCUIT BREAKER 2 EA NS Request Quotation Updated Every Day 5925-00-694-9883 RQST Updated Every
United States (US) 4. 5925-00-694-9883 Marketplace Restrictions Approved Sources Datasheet Management AB100
Restrictions 5925-00-173-7646
5925-00-173-7646 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5925-00-173-7646
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-173-7646
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 1998
Approved Sources 5925-00-173-7646
- Part Number
- Manufacturer
- Status
- F3100
- Manufacturer
- 89946 - Eaton Corporation (Active)
- Primary Buy
- Primary Buy
- 1531789
- 79500 - Westinghouse Electric Corp (Active)
- Primary Buy
- Primary Buy
- 1531-789
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- F3100
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- 1A4161-20SUB33
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- 371D376G20
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- 1222019
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- 1222019-250
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- AB100
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- AB100A
- 79500 - Westinghouse Electric Corp (Active)
- Secondary Buy
- Secondary Buy
- 1531-789
- 65054 - Westinghouse Electric Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 1531789
- 65054 - Westinghouse Electric Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-00-173-7646
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole Two
- Arc Quenching Method [APNQ]
- Deion
- Body Height [ADAU]
- 3.807 Inches Minimum And 3.817 Inches Maximum
- Body Length [ADAQ]
- 9.370 Inches Minimum And 9.380 Inches Maximum
- Body Style [AAQL]
- Multipole-Single Actuator Type
- Body Width [ADAT]
- 4.120 Inches Minimum And 4.130 Inches Maximum
- Boss Height [AJEC]
- 0.120 Inches Minimum And 0.130 Inches Maximum
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 7.245 Inches Minimum And 7.255 Inches Maximum
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 1.369 Inches Minimum And 1.379 Inches Maximum
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 4.495 Inches Minimum And 4.505 Inches Maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 1.369 Inches Minimum And 1.379 Inches Maximum
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 60.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 100.0 Amperes Ac All Locations And 100.0 Amperes Dc All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 15000.0 Ac All Locations And 10000.0 Dc All Locations
- Mounting Facility Type And Quantity [AXHR]
- 4 Unthreaded Hole
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 600.0 Ac All Locations And 250.0 Dc All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- General Purpose
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Special Handling Feature [BBRJ]
- Magnetic
- Trip Release Ambient Temp Rating [CRCF]
- 40.0 Deg Celsius Nominal All Locations
- Trip Release Characteristic [CPRL]
- Instantaneous All Locations
- Trip Release Method [CPRJ]
- Thermal-Magnetic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.276 Inches Minimum And 0.286 Inches Maximum
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 6 Compression
Similar Supply Items to 5925-00-173-7646


















Freight Information 5925-00-173-7646
5925-00-173-7646 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-173-7646 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-173-7646 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-173-7646 is not classified as a special type of cargo when transported by water. 5925-00-173-7646 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.